235 research outputs found

    Implantación percutánea de válvula aórtica en pacientes con esenosis aórtica severa sintomática

    Full text link
    Tesis doctoral inédita leída en la Universidad Autónoma de Madrid, Facultad de Medicina, Departamento de Medicina. Fecha de lectura: 09 de marzo, 201

    Cerebrovascular Events After Transcatheter Aortic Valve Implantation

    Get PDF
    Transcatheter aortic valve implantation (TAVI) has emerged as an alternative less invasive treatment for patients with symptomatic severe aortic stenosis. Despite the technological development and knowledge improvement in recent years, neurological complications remain a concern, especially with the expansion of the technique toward younger and lower risk patients. Clinical cerebrovascular events have an important impact on patients' morbidity and mortality with a multifactorial origin. While cerebral microembolizations during TAVI is a universal phenomenon and embolic protection devices have been developed in an attempt to reduce them, their clinical utility remains unclear. We review the current evidence on cerebrovascular events associated with TAVI and potential preventive strategies

    Coronary Obstruction Following Transcatheter Aortic Valve Implantation for Degenerative Bioprosthetic Surgical Valves: a Systematic Literature Review

    Get PDF
    ABSTRACTBackgroundVery few data exist on coronary obstruction following transcatheter aortic valve implantation (TAVI) for degenerative bioprosthetic valves (valve-in-valve [ViV]). The present trial evaluated, through a systematic review of the literature, the clinical characteristics, management and clinical outcomes of patients with coronary obstruction after ViV-TAVI.MethodsStudies published between 2002 and 2013 evaluating coronary obstruction as a complication of ViV-TAVI were identified using a systematic electronic search. Data on the clinical and procedural characteristics, management of the complication, and clinical outcomes were analyzed.ResultsA total of four publications describing seven patients were identified. Most patients (71%) were women, with mean age of 82±5 years, and STS-PROM score of 9.4±2.6%. Mean left coronary artery (LCA) ostium height and aortic root width were 8.8±1.5mm and 28.0±5.0mm, respectively. Most patients had stented bioprosthetic valves with externally mounted leaflets or stentless aortic bioprosthesis, and the LCA was involved in all patients. Percutaneous coronary intervention (PCI) was attempted in all patients and was successful in four (57%). In-hospital mortality was 42.9% (three cases), all of them after failed PCI.ConclusionsCoronary obstruction following ViV-TAVI occurred more frequently in women with stented bioprosthetic valves with externally mounted leaflets or with stentless bioprosthesis. The LCA was involved in all cases and PCI was successful in 60% of them. Continued efforts may help identify the factors associated with this complication so that appropriate prevention measures may be implemented

    Tratamiento percutáneo de insuficiencia mitral severa por rotura de neocuerdas

    Get PDF
    Percutaneous mitral valve repair techniques have raised substantial interest in recent years, because they allow treating serious lesions avoiding surgical complications with good results in well-selected patients. Echocardiography is absolutely essential in the transcatheter mitral repair procedure and in the selection of candidates for this technique. We present a clinical case of percutaneous edge-to-edge mitral repair treatment in a patient with recurrence of severe mitral regurgitation after having previously undergone neochordal implantation, in which echocardiography played an essential role.Las técnicas de reparación mitral percutánea han generado mucho interés en los últimos años ya que permiten tratar lesiones graves evitando las complicaciones quirúrgicas y con buenos resultados en pacientes bien seleccionados. La ecocardiografía es completamente imprescindible en la reparación mitral transcatéter y en la selección de pacientes candidatos a esta técnica. Presentamos un caso clínico de tratamiento percutáneo de reparación mitral borde a borde en una paciente con recurrencia de insuficiencia mitral grave tras haber sido previamente intervenida con el implante de neocuerdas en el que rol de la ecocardiografía fue esencial

    Impact of Low Flow on the Outcome of High-Risk Patients Undergoing Transcatheter Aortic Valve Replacement

    Get PDF
    ObjectivesThis study sought to assess the impact of baseline left ventricular (LV) outflow, LV ejection fraction (LVEF), and transvalvular gradient on outcomes following transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis (AS).BackgroundLow flow (i.e., reduced stroke volume index [SVi]) can occur with both reduced and preserved LVEF. Low flow is often associated with low gradient despite severe stenosis and with worse outcomes following surgical aortic valve replacement. However, there are few data about the impact of low flow on outcomes following TAVR.MethodsWe retrospectively analyzed the clinical, Doppler-echocardiographic, and outcome data prospectively collected in 639 patients who underwent TAVR for symptomatic severe AS in 2 Canadian centers.ResultsIn this cohort, 334 (52.3%) patients had a low flow (SVi <35 ml/m2) and these patients had increased 30-day mortality (11.4 vs. 5.9%, p = 0.01), 2-year all-cause mortality (35.3 vs. 30.9%, p = 0.005), and 2-year cardiovascular mortality (25.7 vs. 16.8%, p = 0.01) compared with patients with normal flow. Reduced flow was an independent predictor of 30-day mortality (odds ratio: 1.94, p = 0.026), cumulative all-cause mortality (hazard ratio: 1.27 per 10 ml/m² SVi decrease, p = 0.016), and cumulative cardiovascular mortality (hazard ratio: 1.29 per 10 ml/m² decrease, p = 0.04). Despite significant association in univariable analyses, low LVEF and low mean gradient were not found to be independent predictors of outcomes in multivariable analyses.ConclusionsLow flow but not low LVEF or low gradient is an independent predictor of early and late mortality following TAVR in high-risk patients with severe AS. SVi should be integrated in the risk stratification process of these patients

    Incidence, predictive factors and haemodynamic consequences of acute stent recoil following transcatheter aortic valve implantation with a balloon-expandable valve

    Get PDF
    Aims: The elastic behaviour (acute recoil) of a valve prosthesis stent following transcatheter aortic valve implantation (TAVI) is unknown. This study sought to determine the occurrence, severity, predictive factors and haemodynamic consequences of acute recoil following TAVI. Methods and results : A prospective angiographic analysis of the stent frame dimensions in 111 consecutive patients who underwent TAVI with a balloon-expandable valve (36 Edwards SAPIEN; 75 SAPIEN XT) was performed. Acute recoil was defined as the difference between minimal lumen diameter (MLD) at full balloon expansion and immediately after balloon deflation. MLD during balloon inflation was significantly larger than MLD after balloon deflation (23.40±2.31 mm vs. 22.29±2.21 mm, p<0.001), which represented an absolute and percent decrease in stent dimension of 1.10±0.40 mm and 4.70±1.76%, respectively. In the multivariate analysis, the predictors of larger recoil were a higher prosthesis/annulus ratio (r²=0.0624, p=0.015) and the SAPIEN XT prosthesis (r²=0.1276, p=0.001). No significant changes in haemodynamic performance were observed at discharge and follow-up in patients with larger recoil. Conclusions : TAVI with a balloon-expandable valve was systematically associated with a certain degree of valve stent recoil after balloon deflation. A higher degree of valve oversizing and the SAPIEN XT prosthesis predicted a larger degree of stent recoil

    Sex Differences in Mortality After Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis

    Get PDF
    ObjectivesThe aim of this study was to examine sex differences in outcome after transcatheter aortic valve replacement (TAVR) with real-world data from 2 large centers in Canada.BackgroundTranscatheter aortic valve replacement is an effective alternative to surgical valve replacement in symptomatic patients with severe aortic stenosis, but the impact of sex on outcomes remains unclear. The PARTNER (Placement of Aortic Transcatheter Valves) 1A trial demonstrated greater benefit of TAVR over surgery in women, but whether this was due to the poorer surgical outcome of women or better TAVR outcome, compared with men, is unknown.MethodsConsecutive patients (n = 641) undergoing TAVR in Vancouver and Quebec City, Canada, were evaluated. Differences in all-cause mortality were examined with Kaplan-Meier estimates, adjusted logistic regression, and proportional hazards models.ResultsWomen comprised 51.3% of the cohort. Balloon-expandable valves were used in 97% of cases, with transapical approach in 51.7 % women and 38.1% men. Women had more major vascular complications (12.4% vs. 5.4%, p = 0.003) and borderline significantly more major/life-threatening bleeds (21.6% vs. 15.8%, p = 0.08). At baseline, women had higher aortic gradients and worse renal function but better ejection fractions. Men had more comorbidities: prior myocardial infarction, prior revascularization, and chronic obstructive pulmonary disease. The adjusted odds ratio for 30-day all-cause mortality favored women, 0.39 (95% confidence interval: 0.19 to 0.80; p = 0.01), and this benefit persisted for 2 years, hazard ratio 0.60 (95% confidence interval: 0.41 to 0.88; p = 0.008).ConclusionsFemale sex is associated with better short- and long-term survival after TAVR. Added to the PARTNER 1A findings, these results suggest TAVR might be the preferred treatment option for elderly women with symptomatic severe aortic stenosis

    Baseline ECG and prognosis after transcatheter aortic valve implantation: the role of interatrial block

    Full text link
    Background: The clinical significance of conduction disturbances after transcatheter aortic valve implantation has been described; however, little is known about the influence of baseline ECGs in the prognosis of these patients. Our aim was to study the influence of baseline ECG parameters, including interatrial block (IAB), in the prognosis of patients treated with transcatheter aortic valve implantation. Methods and Results: The BIT (Baseline Interatrial Block and Transcatheter Aortic Valve Implantation) registry included 2527 patients with aortic stenosis treated with transcatheter aortic valve implantation. A centralized analysis of baseline ECGs was performed. Patients were divided into 4 groups: normal P wave duration (<120 ms); partial IAB (P wave duration ≥120 ms, positive in the inferior leads); advanced IAB (P wave duration ≥120 ms, biphasic [+/-] morphology in the inferior leads); and nonsinus rhythm (atrial fibrillation/flutter and paced rhythm). The mean age of patients was 82.6±9.8 years and 1397 (55.3%) were women. A total of 960 patients (38.0%) had a normal P wave, 582 (23.0%) had partial IAB, 300 (11.9%) had advanced IAB, and 685 (27.1%) presented with nonsinus rhythm. Mean follow‐up duration was 465±171 days. Advanced IAB was the only independent predictor of all‐cause mortality (hazard ratio [HR], 1.48; 95% CI, 1.10-1.98 [P=0.010]) and of the composite end point (death/stroke/new atrial fibrillation) (HR, 1.51; 95% CI, 1.17-1.94 [P=0.001]). Conclusions: Baseline ECG characteristics influence the prognosis of patients with aortic stenosis treated with transcatheter aortic valve implantation. Advanced IAB is present in about an eighth of patients and is associated with all‐cause death and the composite end point of death, stroke, and new atrial fibrillation during follow‐up

    Eco-fusión. Aplicación en el intervencionismo estructural cardíaco

    Get PDF
    The evolution in percutaneous structural intervention has generated a parallel development in advanced imaging techniques. Echocardiography plays a key role in structural intervention in patient selection, assessment during the fluoroscopy and immediate analysis of outcomes and early detection of complications; echo-fusion images appear as a complementary tool in which two techniques with dynamic images are complemented in a single image in order to guide, decrease intervention time and reduce complications.La evolución en el intervencionismo estructural percutáneo ha generado un desarrollo paralelo en las técnicas de imagen avanzada. La ecocardiografía en el intervencionismo estructural juega un papel básico en la selección de los pacientes, en la valoración durante el procedimiento y en el análisis inmediato de los resultados y la detección precoz de complicaciones. Las imágenes de fusión eco/fluoroscopia aparecen como una herramienta complementaria en la que dos técnicas con imágenes dinámicas se complementan en una sola imagen con el fin de orientar, disminuir el tiempo de intervención y disminuir las complicaciones
    corecore