258 research outputs found
Cultural competency of health-care providers in a Swiss University Hospital: self-assessed cross-cultural skillfulness in a cross-sectional study.
BACKGROUND: As the diversity of the European population evolves, measuring providers' skillfulness in cross-cultural care and understanding what contextual factors may influence this is increasingly necessary. Given limited information about differences in cultural competency by provider role, we compared cross-cultural skillfulness between physicians and nurses working at a Swiss university hospital.
METHODS: A survey on cross-cultural care was mailed in November 2010 to front-line providers in Lausanne, Switzerland. This questionnaire included some questions from the previously validated Cross-Cultural Care Survey. We compared physicians' and nurses' mean composite scores and proportion of "3-good/4-very good" responses, for nine perceived skillfulness items (4-point Likert-scale) using the validated tool. We used linear regression to examine how provider role (physician vs. nurse) was associated with composite skillfulness scores, adjusting for demographics (gender, non-French dominant language), workplace (time at institution, work-unit "sensitized" to cultural-care), reported cultural-competence training, and cross-cultural care problem-awareness.
RESULTS: Of 885 questionnaires, 368 (41.2%) returned the survey: 124 (33.6%) physicians and 244 (66.4%) nurses, reflecting institutional distribution of providers. Physicians had better mean composite scores for perceived skillfulness than nurses (2.7 vs. 2.5, p < 0.005), and significantly higher proportion of "good/very good" responses for 4/9 items. After adjusting for explanatory variables, physicians remained more likely to have higher skillfulness (β = 0.13, p = 0.05). Among all, higher skillfulness was associated with perception/awareness of problems in the following areas: inadequate cross-cultural training (β = 0.14, p = 0.01) and lack of practical experience caring for diverse populations (β = 0.11, p = 0.04). In stratified analyses among physicians alone, having French as a dominant language (β = -0.34, p < 0.005) was negatively correlated with skillfulness.
CONCLUSIONS: Overall, there is much room for cultural competency improvement among providers. These results support the need for cross-cultural skills training with an inter-professional focus on nurses, education that attunes provider awareness to the local issues in cross-cultural care, and increased diversity efforts in the work force, particularly among physicians
Le point sur la pratique infirmière avancée [Update on advanced practice nursing].
We report outcomes of a clinical audit examining criteria used in clinical practice to rationalize endotracheal tube (ETT) suction, and the extent these matched criteria in the Endotracheal Suction Assessment Tool(ESAT)©. A retrospective audit of patient notes (N = 292) and analyses of criteria documented by pediatric intensive care nurses to rationalize ETT suction were undertaken. The median number of documented respiratory and ventilation status criteria per ETT suction event that matched the ESAT© criteria was 2 [Interquartile Range (IQR) 1-6]. All criteria listed within the ESAT© were documented within the reviewed notes. A direct link was established between criteria used for current clinical practice of ETT suction and the ESAT©. The ESAT©, therefore, reflects documented clinical decision making and could be used as both a clinical and educational guide for inexperienced pediatric critical care nurses. Modification to the ESAT© requires "preparation for extubation" to be added
Consequences of the multipatient use of a single-patient capillary blood sampling device (CBSD)
Introduction/objectives: Multipatient use of a single-patient CBSD occurred inan outpatient clinic during 4 to 16 months before itsnotification. We looked for transmission of blood-bornepathogens among exposed patients.Methods: Exposed patients underwent serology testing for HBV,HCV and HIV. Patients with isolated anti-HBc receivedone dose of hepatitis B vaccine to look for a memoryimmune response. Possible transmissions were investigatedby mapping visits and sequencing of the viral genomeif needed.Results: Of 280 exposed patients, 9 had died without suspicionof blood-borne infection, 3 could not be tested, and 5declined investigations. Among the 263 (93%) testedpatients, 218 (83%) had negative results. We confirmeda known history of HCV infection in 6 patients (1 coinfectedby HIV), and also identified resolved HBVinfection in 37 patients, of whom 18 were alreadyknown. 2 patients were found to have a previouslyunknown HCV infection. According to the time elapsedfrom the closest previous visit of a HCV-infected potentialsource patient, we could rule out nosocomial transmissionin one case (14 weeks) but not in the other (1day). In the latter, however, transmission was deemedvery unlikely by 2 reference centers based on thesequences of the E1 and HVR1 regions of the virus.Conclusion: We did not identify any transmission of blood-bornepathogens in 263 patients exposed to a single-patientCBSD, despite the presence of potential source cases.Change of needle and disinfection of the device betweenpatients may have contributed to this outcome.Although we cannot exclude transmission of HBV, previousacquisition in endemic countries is a more likelyexplanation in this multi-national population
Structure of Be probed via secondary beam reactions
The low-lying level structure of the unbound neutron-rich nucleus Be
has been investigated via breakup on a carbon target of secondary beams of
B at 35 MeV/nucleon. The coincident detection of the beam velocity
Be fragments and neutrons permitted the invariant mass of the
Be+ and Be++ systems to be reconstructed. In the case of
the breakup of B, a very narrow structure at threshold was observed in
the Be+ channel. Contrary to earlier stable beam fragmentation
studies which identified this as a strongly interacting -wave virtual state
in Be, analysis here of the Be++ events demonstrated that
this was an artifact resulting from the sequential-decay of the
Be(2) state. Single-proton removal from B was found to
populate a broad low-lying structure some 0.70 MeV above the neutron-decay
threshold in addition to a less prominent feature at around 2.4 MeV. Based on
the selectivity of the reaction and a comparison with (0-3)
shell-model calculations, the low-lying structure is concluded to most probably
arise from closely spaced J=1/2 and 5/2 resonances
(E=0.400.03 and 0.85 MeV), whilst the broad
higher-lying feature is a second 5/2 level (E=2.350.14 MeV). Taken
in conjunction with earlier studies, it would appear that the lowest 1/2
and 1/2 levels lie relatively close together below 1 MeV.Comment: 14 pages, 13 figures, 2 tables. Accepted for publication in Physical
Review
A new experiment for the determination of the 18F(p,alpha) reaction rate at nova temperatures
The 18F(p,alpha) reaction was recognized as one of the most important for
gamma ray astronomy in novae as it governs the early 511 keV emission. However,
its rate remains largely uncertain at nova temperatures. A direct measurement
of the cross section over the full range of nova energies is impossible because
of its vanishing value at low energy and of the short 18F lifetime. Therefore,
in order to better constrain this reaction rate, we have performed an indirect
experiment taking advantage of the availability of a high purity and intense
radioactive 18F beam at the Louvain La Neuve RIB facility. We present here the
first results of the data analysis and discuss the consequences.Comment: Contribution to the Classical Novae Explosions conference, Sitges,
Spain, 20-24 May 2002, 5 pages, 3 figure
Structure of 12Be: intruder d-wave strength at N=8
The breaking of the N=8 shell-model magic number in the 12Be ground state has
been determined to include significant occupancy of the intruder d-wave
orbital. This is in marked contrast with all other N=8 isotones, both more and
less exotic than 12Be. The occupancies of the 0 hbar omega neutron p1/2-orbital
and the 1 hbar omega, neutron d5/2 intruder orbital were deduced from a
measurement of neutron removal from a high-energy 12Be beam leading to bound
and unbound states in 11Be.Comment: 5 pages, 2 figure
The CMS Event Builder
The data acquisition system of the CMS experiment at the Large Hadron
Collider will employ an event builder which will combine data from about 500
data sources into full events at an aggregate throughput of 100 GByte/s.
Several architectures and switch technologies have been evaluated for the DAQ
Technical Design Report by measurements with test benches and by simulation.
This paper describes studies of an EVB test-bench based on 64 PCs acting as
data sources and data consumers and employing both Gigabit Ethernet and Myrinet
technologies as the interconnect. In the case of Ethernet, protocols based on
Layer-2 frames and on TCP/IP are evaluated. Results from ongoing studies,
including measurements on throughput and scaling are presented.
The architecture of the baseline CMS event builder will be outlined. The
event builder is organised into two stages with intelligent buffers in between.
The first stage contains 64 switches performing a first level of data
concentration by building super-fragments from fragments of 8 data sources. The
second stage combines the 64 super-fragments into full events. This
architecture allows installation of the second stage of the event builder in
steps, with the overall throughput scaling linearly with the number of switches
in the second stage. Possible implementations of the components of the event
builder are discussed and the expected performance of the full event builder is
outlined.Comment: Conference CHEP0
Single-Proton Removal Reaction Study of 16B
The low-lying level structure of the unbound system B has been
investigated via single-proton removal from a 35 MeV/nucleon C beam. The
coincident detection of the beam velocity B fragment and neutron allowed
the relative energy of the in-flight decay of B to be reconstructed. The
resulting spectrum exhibited a narrow peak some 85 keV above threshold. It is
argued that this feature corresponds to a very narrow (100 keV)
resonance, or an unresolved multiplet, with a dominant + configuration which decays by d-wave neutron
emission.Comment: 16 pages, 5 figures, 1 table, submitted to Phys. Lett.
Three-body correlations in Borromean halo nuclei
Three-body correlations in the dissociation of two-neutron halo nuclei are
explored using a technique based on intensity interferometry and Dalitz plots.
This provides for the combined treatment of both the n-n and core-n
interactions in the exit channel. As an example, the breakup of 14Be into
12Be+n+n by Pb and C targets has been analysed and the halo n-n separation
extracted. A finite delay between the emission of the neutrons in the reaction
on the C target was observed and is attributed to 13Be resonances populated in
sequential breakup.Comment: 5 pages, 4 figures, submitted to PR
- …