11 research outputs found

    Different osteosyntheses for Colles' fracture: A mechanical study in 42 cadaver bones

    Get PDF
    Background and purpose In recent years several different plate designs for internal fixation of fractures of the distal radius have been developed. However, few biomechanical studies have been performed to compare these new implants. The purpose of this study was to compare the mechanical properties of 5 different commercially available plates (3 volar and 2 dorsal) with standard K-wire fixation using a distal radial cadaver model

    An experimental study of low-level laser therapy in rat Achilles tendon injury

    Get PDF
    The aim of this controlled animal study was to investigate the effect of low-level laser therapy (LLLT) administered 30 min after injury to the Achilles tendon. The study animals comprised 16 Sprague Dawley male rats divided in two groups. The right Achilles tendons were injured by blunt trauma using a mini guillotine, and were treated with LLLT or placebo LLLT 30 min later. The injury and LLLT procedures were then repeated 15 hours later on the same tendon. One group received active LLLT (λ = 904 nm, 60 mW mean output power, 0.158 W/cm2 for 50 s, energy 3 J) and the other group received placebo LLLT 23 hours after LLLT. Ultrasonographic images were taken to measure the thickness of the right and left Achilles tendons. Animals were then killed, and all Achilles tendons were tested for ultimate tensile strength (UTS). All analyses were performed by blinded observers. There was a significant increase in tendon thickness in the active LLLT group when compared with the placebo group (p < 0.05) and there were no significant differences between the placebo and uninjured left tendons. There were no significant differences in UTS between laser-treated, placebo-treated and uninjured tendons. Laser irradiation of the Achilles tendon at 0.158 W/cm2 for 50 s (3 J) administered within the first 30 min after blunt trauma, and repeated after 15 h, appears to lead to edema of the tendon measured 23 hours after LLLT. The guillotine blunt trauma model seems suitable for inflicting tendon injury and measuring the effects of treatment on edema by ultrasonography and UTS. More studies are needed to further refine this model

    Are Inflatable Nails an Alternative to Interlocked Nails in Tibial Fractures?

    No full text
    Recently developed inflatable nails avoid reaming and interlocking screws in tibial fractures and reflect a new principle for stabilization of long bone fractures. We asked if the bending stiffness, rotational rigidity, or play (looseness of rotation) differed between an inflatable versus large-diameter reamed interlocked nails, and whether the maximal torque to failure of the two bone-implant constructs differed. In a cadaveric model, we compared the biomechanical properties with those of an interlocked nail in eight pairs of fractured tibial bones. Bending stiffness, rotational rigidity, play (looseness in rotation), and torsional strength within 20° rotation were investigated using a biaxial servohydraulic testing system. For all biomechanical variables, we found a large interindividual variance between the pairs attributable to bone quality (osteoporosis) for both fixation methods. The inflatable nail had a higher bending stiffness, with a mean difference of 58 N/mm, and a lower torsional strength, with a mean difference of 13.5 Nm, compared with the locked nail. During torsional testing we noted slippage between the inflatable nail and bone. We observed no differences in play or rotational rigidity. Given the lower torsional strength we recommend caution with weightbearing until there are signs of fracture consolidation
    corecore