12 research outputs found

    Latest Trends in Pollutant Accumulations at Threatening Levels in Energy-Efficient Residential Buildings with and without Mechanical Ventilation: A Review

    Get PDF
    Improving the energy efficiency of buildings is a major target in developed countries toward decreasing their energy consumption and CO2 emissions. To meet this target, a large number of countries have established energy codes that require buildings to be airtight. While such a retrofitting approach has improved health outcomes in areas with heavy traffic, it has worsened the health outcomes in Nordic countries and increased the risk of lung cancer in areas with high levels of radon emissions. This review highlights the importance of adapting the characteristics of energy-efficient residential buildings to the location, age, and health of inhabitants to guarantee healthy indoor pollutant levels. The implementation of mechanical ventilation in new energy-efficient buildings has solved some of these problems; however, for others, a decrease in the level of outdoor pollutants was still required in order to achieve a good indoor air quality. A good balance between the air exchange rate and the air humidity level (adapted to the location) is key to ensuring that exposure to the various pollutants that accumulate inside energy-efficient buildings is low enough to avoid affecting inhabitants′ health. Evidence of the protective effect of mechanical ventilation should be sought in dwellings where natural ventilation allows pollutants to accumulate to threatening levels. More studies should be carried out in African and Asian countries, which, due to their rapid urbanization, use massive volumes of unproven/unrated building materials for fast-track construction, which are frequent sources of formaldehyde and VOC emissions

    Risk Exposure to Particles – including Legionella pneumophila – emitted during Showering with Water-Saving Showers

    Get PDF
    The increase in legionellosis incidence in the general population in recent years calls for a better characterization of the sources of infection, such as showering. Water-efficient shower systems that use water atomization technology may emit slightly more inhalable bacteria-sized particles than traditional systems, which may increase the risk of users inhaling contaminants associated with these water droplets. To evaluate the risk, the number and mass of inhalable water droplets emitted by twelve showerheads—eight using water-atomization technology and four using continuous-flow technology— were monitored in a shower stall. The water-atomizing showers tested not only had lower flow rates, but also larger spray angles, less nozzles, and larger nozzle diameters than those of the continuous-flow showerheads. A difference in the behavior of inhalable water droplets between the two technologies was observed, both unobstructed or in the presence of a mannequin. The evaporation of inhalable water droplets emitted by the water-atomization showers favored a homogenous distribution in the shower stall. In the presence of the mannequin, the number and mass of inhalable droplets increased for the continuous-flow showerheads and decreased for the water-atomization showerheads. The water-atomization showerheads emitted less inhalable water mass than the continuous-flow showerheads did per unit of time; however, they generally emitted a slightly higher number of inhalable droplets—only one model performed as well as the continuous-flow showerheads in this regard. To specifically assess the aerosolisation rate of bacteria, in particular of the opportunistic water pathogen Legionella pneumophila, during showering controlled experiments were run with one atomization showerhead and one continuous-flow, first inside a glove box, second inside a shower stall. The bioaerosols were sampled with a Coriolis® air sampler and the total number of viable (cultivable and noncultivable) bacteria was determined by flow cytometry and culture. We found that the rate of viable and cultivable Legionella aerosolized from the water jet was similar between the two showerheads: the viable fraction represents 0.02% of the overall bacteria present in water, while the cultivable fraction corresponds to only 0.0005%. The two showerhead models emitted a similar ratio of airborne Legionella viable and cultivable per volume of water used. Similar results were obtained with naturally contaminated hoses tested in shower stall. Therefore, the risk of exposure to Legionella is not expected to increase significantly with the new generation of water-efficient showerheads

    Comparative analysis of diversity and environmental niches of soil bacterial, archaeal, fungal and protist communities reveal niche divergences along environmental gradients in the Alps

    Get PDF
    Although widely used in ecology, comparative analyses of diversity and niche properties are still lacking for microorganisms, especially focusing on niche variations. Quantifying the niches of microbial taxa is necessary to then forecast how taxa and the communities they compose might respond to environmental changes. In this study, we first identified important topoclimatic, edaphic, spatial and biotic drivers of the alpha and beta di-versity of bacterial, archaeal, fungal and protist communities. Then, we calculated the niche breadth and position of each taxon along the important environmental gradients to determine how these vary within and among the taxonomic groups. We found that edaphic properties were the most important drivers of both, community di-versity and composition, for all microbial groups. Protists and bacteria presented the largest niche breadths on average, followed by archaea, with fungi displaying the smallest. Niche breadth generally decreased towards environmental extremes, especially along edaphic gradients, suggesting increased specialization of microbial taxa in highly selective environments. Overall, we showed that microorganisms have well defined niches, as do macro-organisms, likely driving part of the observed spatial patterns of community variations. Assessing niche variation more widely in microbial ecology should open new perspectives, especially to tackle global change effects on microbes.Peer reviewe

    Low spatial autocorrelation in mountain biodiversity data and model residuals

    Get PDF
    Spatial autocorrelation (SAC) is a common feature of ecological data where observations tend to be more similar at some geographic distance(s) than expected by chance. Despite the implications of SAC for data dependencies, its impact on the performance of species distribution models (SDMs) remains controversial, with reports of both strong and negligible impacts on inference. Yet, no study has comprehensively assessed the prevalence and the strength of SAC in the residuals of SDMs over entire geographic areas. Here, we used a large-scale spatial inventory in the western Swiss Alps to provide a thorough assessment of the importance of SAC for (1) 850 species belonging to nine taxonomic groups, (2) six predictors commonly used for modeling species distributions, and (3) residuals obtained from SDMs fitted with two algorithms with the six predictors included as covariates. We used various statistical tools to evaluate (1) the global level of SAC, (2) the spatial pattern and spatial extent of SAC, and (3) whether local clusters of SAC can be detected. We further investigated the effect of the sampling design on SAC levels. Overall, while environmental predictors expectedly displayed high SAC levels, SAC in biodiversity data was rather low overall and vanished rapidly at a distance of similar to 5-10 km. We found low evidence for the existence of local clusters of SAC. Most importantly, model residuals were not spatially autocorrelated, suggesting that inferences derived from SDMs are unlikely to be affected by SAC. Further, our results suggest that the influence of SAC can be reduced by a careful sampling design. Overall, our results suggest that SAC is not a major concern for rugged mountain landscapes.Peer reviewe

    Predicting spatial patterns of soil bacteria under current and future environmental conditions

    Get PDF
    Soil bacteria are largely missing from future biodiversity assessments hindering comprehensive forecasts of ecosystem changes. Soil bacterial communities are expected to be more strongly driven by pH and less by other edaphic and climatic factors. Thus, alkalinisation or acidification along with climate change may influence soil bacteria, with subsequent influences for example on nutrient cycling and vegetation. Future forecasts of soil bacteria are therefore needed. We applied species distribution modelling (SDM) to quantify the roles of environmental factors in governing spatial abundance distribution of soil bacterial OTUs and to predict how future changes in these factors may change bacterial communities in a temperate mountain area. Models indicated that factors related to soil (especially pH), climate and/or topography explain and predict part of the abundance distribution of most OTUs. This supports the expectations that microorganisms have specific environmental requirements (i.e., niches/envelopes) and that they should accordingly respond to environmental changes. Our predictions indicate a stronger role of pH over other predictors (e.g. climate) in governing distributions of bacteria, yet the predicted future changes in bacteria communities are smaller than their current variation across space. The extent of bacterial community change predictions varies as a function of elevation, but in general, deviations from neutral soil pH are expected to decrease abundances and diversity of bacteria. Our findings highlight the need to account for edaphic changes, along with climate changes, in future forecasts of soil bacteria.Peer reviewe

    Respiratory health effects of fifteen years of improved collective protection in a wheat-processing worker population.

    No full text
    International audienceOccupational exposure to grain dust causes respiratory symptoms and pathologies. To decrease these effects, major changes have occurred in the grain processing industry in the last twenty years. However, there are no data on the effects of these changes on workers' respiratory health. The aim of this study was to evaluate the respiratory health of grain workers and farmers involved in different steps of the processing industry of wheat, the most frequently used cereal in Europe, fifteen years after major improvements in collective protective equipment due to mechanisation. Information on estimated personal exposure to wheat dust was collected from 87 workers exposed to wheat dust and from 62 controls. Lung function (FEV1, FVC, and PEF), exhaled nitrogen monoxide (FENO) and respiratory symptoms were assessed after the period of highest exposure to wheat during the year. Linear regression models were used to explore the associations between exposure indices and respiratory effects. Acute symptoms - cough, sneezing, runny nose, scratchy throat - were significantly more frequent in exposed workers than in controls. Increased mean exposure level, increased cumulative exposure and chronic exposure to more than 6 mg.m (-3) of inhaled wheat dust were significantly associated with decreased spirometric parameters, including FEV1 and PEF (40 ml and 123 ml.s (-1) ), FEV1 and FVC (0.4 ml and 0.5 ml per 100 h.mg.m (-3) ), FEV1 and FVC (20 ml and 20 ml per 100 h at >6 mg.m (-3) ). However, no increase in FENO was associated with increased exposure indices. The lung functions of wheat-related workers are still affected by their cumulative exposure to wheat dust, despite improvements in the use of collective protective equipment

    Respiratory health effects of fifteen years of improved collective protection in a wheat-processing worker population

    No full text
    Introduction Occupational exposure to grain dust causes respiratory symptoms and pathologies. To decrease these effects, major changes have occurred in the grain processing industry in the last twenty years. However, there are no data on the effects of these changes on workers’ respiratory health. Objectives The aim of this study was to evaluate the respiratory health of grain workers and farmers involved in different steps of the processing industry of wheat, the most frequently used cereal in Europe, fifteen years after major improvements in collective protective equipment due to mechanisation. Material and Methods Information on estimated personal exposure to wheat dust was collected from 87 workers exposed to wheat dust and from 62 controls. Lung function (FEV 1 , FVC, and PEF), exhaled nitrogen monoxide (F E NO) and respiratory symptoms were assessed after the period of highest exposure to wheat during the year. Linear regression models were used to explore the associations between exposure indices and respiratory effects. Results Acute symptoms – cough, sneezing, runny nose, scratchy throat – were significantly more frequent in exposed workers than in controls. Increased mean exposure level, increased cumulative exposure and chronic exposure to more than 6 mg.m -3 of inhaled wheat dust were significantly associated with decreased spirometric parameters, including FEV 1 and PEF (40 ml and 123 ml.s -1 ), FEV 1 and FVC (0.4 ml and 0.5 ml per 100 h.mg.m -3 ), FEV 1 and FVC (20 ml and 20 ml per 100 h at >6 mg.m -3 ). However, no increase in F E NO was associated with increased exposure indices. Conclusions The lung functions of wheat-related workers are still affected by their cumulative exposure to wheat dust, despite improvements in the use of collective protective equipment

    Respiratory health effects of fifteen years of improved collective protection in a wheat-processing worker population.

    No full text
    International audienceOccupational exposure to grain dust causes respiratory symptoms and pathologies. To decrease these effects, major changes have occurred in the grain processing industry in the last twenty years. However, there are no data on the effects of these changes on workers' respiratory health. The aim of this study was to evaluate the respiratory health of grain workers and farmers involved in different steps of the processing industry of wheat, the most frequently used cereal in Europe, fifteen years after major improvements in collective protective equipment due to mechanisation. Information on estimated personal exposure to wheat dust was collected from 87 workers exposed to wheat dust and from 62 controls. Lung function (FEV1, FVC, and PEF), exhaled nitrogen monoxide (FENO) and respiratory symptoms were assessed after the period of highest exposure to wheat during the year. Linear regression models were used to explore the associations between exposure indices and respiratory effects. Acute symptoms - cough, sneezing, runny nose, scratchy throat - were significantly more frequent in exposed workers than in controls. Increased mean exposure level, increased cumulative exposure and chronic exposure to more than 6 mg.m (-3) of inhaled wheat dust were significantly associated with decreased spirometric parameters, including FEV1 and PEF (40 ml and 123 ml.s (-1) ), FEV1 and FVC (0.4 ml and 0.5 ml per 100 h.mg.m (-3) ), FEV1 and FVC (20 ml and 20 ml per 100 h at >6 mg.m (-3) ). However, no increase in FENO was associated with increased exposure indices. The lung functions of wheat-related workers are still affected by their cumulative exposure to wheat dust, despite improvements in the use of collective protective equipment

    Comparison of two methods for bioaerosol sampling and characterization in a low-biomass chamber environment

    No full text
    Bioaerosols are emitted from various sources into the indoor environment and can positively and negatively impact human health. Humans are the major source of bioaerosol emissions indoors, specifically for bacteria. However, efficient sampling to guarantee successful downstream analyses can be challenging due to the relatively low bioaerosol concentrations in many indoor spaces and variable susceptibility of bioaerosols to sampling stress. Establishing standard procedures for collecting bacteria in low biomass indoor environments can help advance the field. We compared the performance of two approaches (sampling with a personal environmental monitor (PEM) and a two-stage dry cyclone sampler) to capture the bacterial emission from human participants in a controlled chamber environment. The comparison was based on quantifying the DNA yield and characterizing the bacterial community diversity by metabarcoding of the 16S rRNA gene. We found notable differences in the performance of the samplers. The cyclone sampler collected significantly more DNA and 16S rRNA gene copies including Gram-negative bacteria than the PEM sampler (p < 0.001). The bacterial barcode sequencing revealed a significant difference in the diversity of bacteria captured by the two samplers (p < 0.05), with a higher diversity of Gram-negative bacteria captured by PEM than the cyclone sampler. Overall, this study showed that both sampling approaches efficiently sampled in low biomass indoor environments, however with substantial differences in captured DNA concentrations, bacterial concentrations, and bacterial diversity. Our results indicate that bioaerosol sampler choice is highly research question dependent, and this study provides data support to make informed choices
    corecore