960 research outputs found

    Hysteresis and re-entrant melting of a self-organized system of classical particles confined in a parabolic trap

    Full text link
    A self-organized system composed of classical particles confined in a two-dimensional parabolic trap and interacting through a potential with a short-range attractive part and long-range repulsive part is studied as function of temperature. The influence of the competition between the short-range attractive part of the inter-particle potential and its long-range repulsive part on the melting temperature is studied. Different behaviors of the melting temperature are found depending on the screening length (κ\kappa) and the strength (BB) of the attractive part of the inter-particle potential. A re-entrant behavior and a thermal induced phase transition is observed in a small region of (κ,B\kappa,B)-space. A structural hysteresis effect is observed as a function of temperature and physically understood as due to the presence of a potential barrier between different configurations of the system.Comment: 8 pages, 6 figure

    Transition from single-file to two-dimensional diffusion of interacting particles in a quasi-one-dimensional channel

    Full text link
    Diffusive properties of a monodisperse system of interacting particles confined to a \textit{quasi}-one-dimensional (Q1D) channel are studied using molecular dynamics (MD) simulations. We calculate numerically the mean-squared displacement (MSD) and investigate the influence of the width of the channel (or the strength of the confinement potential) on diffusion in finite-size channels of different shapes (i.e., straight and circular). The transition from single-file diffusion (SFD) to the two-dimensional diffusion regime is investigated. This transition (regarding the calculation of the scaling exponent (α\alpha) of the MSD tα\propto t^{\alpha}) as a function of the width of the channel, is shown to change depending on the channel's confinement profile. In particular the transition can be either smooth (i.e., for a parabolic confinement potential) or rather sharp/stepwise (i.e., for a hard-wall potential), as distinct from infinite channels where this transition is abrupt. This result can be explained by qualitatively different distributions of the particle density for the different confinement potentials.Comment: 13 pages, 11 figure

    Correlation between the optical veiling and accretion properties: A case study of the classical T Tauri star DK Tau

    Full text link
    Classical T Tauri stars (cTTs) accrete from their circumstellar disk. The material falls onto the stellar surface, producing an accretion shock, which generates veiling in a star's spectra. In addition, the shock causes a localized accretion spot at the level of the chromosphere. Our goal is to investigate the accretion, particularly the mass accretion rates (Macc), for the cTTs DK Tau, over two periods of 17 and 29 days, using two different procedures for comparison purposes. The first method relies on the derivation of the accretion luminosity via accretion-powered emission lines. The second compares the variability of the optical veiling with accretion shock models to determine mass accretion rates. We used observations taken in 2010 and 2012 with the ESPaDOnS spectropolarimeter at the CFHT. We find peak values of the veiling (at 550 nm) ranging from 0.2 to 1.3, with a steeper trend across the wavelength range for higher peak values. When using the accretion-powered emission lines, we find mass accretion rate values ranging from log(Macc[Msol/yr]) = -8.20 to log(Macc[Msol/yr]) = -7.40. This agrees with the values found in the literature, as well as the values calculated using the accretion shock models and the veiling. In addition, we identify a power-law correlation between the values of the accretion luminosity and the optical veiling. For the 2010 observations, using the values of the filling factors (which represent the area of the star covered by an accretion spot) derived from the shock models, we infer that the accretion spot was located between +45 degrees and +75 degrees in latitude. We show that both methods of determining the mass accretion rate yield similar results. We also present a helpful means of confirming the accretion luminosity values by measuring the veiling at a single wavelength in the optical

    Complications and outcome of cats with congenital extrahepatic portosystemic shunts treated with thin film: Thirty-four cases (2008-2017)

    Get PDF
    Background: Congenital extrahepatic portosystemic shunts (CEHPSS) are rare in cats. Outcome after attenuation of CEHPSS with thin film has been described in a small number of cases. Objectives: To describe the clinical presentation, postoperative complications, and outcome of cats treated with thin film to attenuate CEHPSS. Animals: Thirty‐four cats with CEHPSS were identified from the database of 3 institutions over 9 years. Methods: Retrospective study. Medical records were reviewed to identify cats with a diagnosis of a CEHPSS that underwent surgical attenuation. Congenital extrahepatic portosystemic shunts were suspected from clinical signs, clinicopathologic findings, and diagnostic imaging, and confirmed at exploratory laparotomy. Cats treated with thin film band attenuation were included. Postoperative complications and follow‐up were recorded. Results: Complications were recorded in 11 of 34 cats. Deaths related to CEHPSS occurred in 6 of 34; 4 cats did not survive to discharge. Persistent seizures were the cause of death in 4 cats. Seizures were recorded in 8 of 34 cats after surgery; all these cats received preoperative antiepileptic drugs. Serum bile acid concentrations normalized in 25 of 28 of the cats for which data was available. Three cats had persistently increased serum bile acid concentrations and underwent a second exploratory laparotomy. One had a patent shunt, the other 2 had multiple acquired portosystemic shunts. Median follow‐up was 8 months (0.5‐84 months). Conclusions and Clinical Importance: Congenital extrahepatic portosystemic shunts attenuation using thin film in cats carries a good short‐ and mid‐term prognosis if they survive the postoperative period. Seizures were the most common cause of death

    Improving Breast Cancer Treatment Specificity Using Aptamers Obtained by 3D Cell-SELEX

    Get PDF
    Three-dimensional spheroids of non-malignant MCF10A and malignant SKBR3 breast cells were used for subsequent 3D Cell-SELEX to generate aptamers for specific binding and treatment of breast cancer cells. Using 3D Cell-SELEX combined with Next-Generation Sequencing and bioinformatics, ten abundant aptamer families with specific structures were identified that selectively bind to SKBR3, and not to MCF10A cells. Multivalent aptamer polymers were synthesized by co-polymerization and analyzed for binding performance as well as therapeutic efficacy. Binding performance was determined by confocal fluorescence imaging and revealed specific binding and efficient internalization of aptamer polymers into SKBR3 spheroids. For therapeutic purposes, DNA sequences that intercalate the cytotoxic drug doxorubicin were co-polymerized into the aptamer polymers. Viability tests show that the drug-loaded polymers are specific and effective in killing SKBR3 breast cancer cells. Thus, the 3D-selected aptamers enhanced the specificity of doxorubicin against malignant over non-malignant breast cells. The innovative modular DNA aptamer platform based on 3D Cell SELEX and polymer multivalency holds great promise for diagnostics and treatment of breast cancer

    The P gene of Newcastle disease virus does not encode an accessory X protein

    Get PDF
    Many paramyxoviruses encode non-essential accessory proteins that are involved in the regulation of virus replication and inhibition of cellular antiviral responses. It has been suggested that the P gene mRNA of Newcastle disease virus (NDV) encodes an accessory protein ¿ the so-called X protein ¿ by translation initiation at a conserved in-frame AUG codon at position 120. Using a monoclonal antibody that specifically detected the P and X proteins, it was shown that an accessory X protein was not expressed in NDV-infected cells. Recombinant NDV strains in which the AUG was changed into a GCC (Ala) or GUC (Val) codon were viable but showed a reduction in virulence, probably because the amino acid change affected the function of the P and/or V protein

    Low-temperature structural model of hcp solid C70_{70}

    Full text link
    We report intermolecular potential-energy calculations for solid C_70{70} and determine the optimum static orientations of the molecules at low temperature; we find them to be consistent with the monoclinic structural model proposed by us in an earlier report [Solid State Commun. {\bf 105), 247 (1998)]. This model indicates that the C_5 axis of the molecule is tilted by an angle \approx18^o from the monoclinic b axis in contrast with the molecular orientation proposed by Verheijen {\it et al.} [J. Chem. Phys. {\bf 166}, 287 (1992)] where the C_5 axis is parallel to the monoclinic b axis. In this calculation we have incorporated the effective bond charge Coulomb potential together with the Lennard-Jones potential between the molecule at the origin of the monoclinic unit cell and its six nearest neighbours, three above and three below. The minimum energy configuration for the molecular orientations turns out to be at θ\theta=18^o, ϕ\phi=8^o, and ψ\psi=5^o, where θ\theta, ϕ\phi, and ψ\psi define the molecular orientations.Comment: ReVTeX (4 pages) + 2 PostScript figure

    No difference in component migration at five years between the cemented cruciate- retaining ATTUNE and PFC-Sigma knee prosthesis: an update of a randomized clinical radiostereometry trial

    Get PDF
    AimsConflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five -year follow -up results comparing cemented ATTUNE and PFC- Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes.MethodsA total of 74 primary TKAs were included in this single -blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months' follow -up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively.ResultsAt five -year follow -up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC- Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC- Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow -up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC- Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five -year follow -up compared to the PFC- Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups.ConclusionMTPM migration at five -year follow -up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long -term ATTUNE performance may be expected to be comparable to the clinically well -performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA.Orthopaedics, Trauma Surgery and Rehabilitatio

    A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design

    Get PDF
    AimsThe primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs).MethodsA single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively.ResultsThe overall migration (mean maximum total point motion (MPTM)) at two years was comparable: mean 1.13 mm (95% confidence interval (CI), 0.97 to 1.30) for the ATTUNE and 1.16 mm (95% CI, 0.99 to 1.35) for the PFC-sigma. At two years, the mean backward tilting was -0.43 degrees (95% CI, -0.65 to -0.21) for the ATTUNE and 0.08 degrees (95% CI -0.16 to 0.31), for the PFC-sigma. Overall migration between the first and second postoperative year was negligible for both components.The clinical outcomes and PROMs improved compared with preoperative scores and were not different between groups. Radiolucencies at the implant-cement interface were mainly seen below the medial baseplate: 17% in the ATTUNE and 3% in the PFC-sigma at two weeks, and at two years 42% and 9% respectively (p = 0.001).ConclusionIn the first two postoperative years the initial version of the ATTUNE tibial component was not inferior with respect to overall migration, although it showed relatively more backwards tilting and radiolucent lines at the implant-cement interface than the PFC-sigma. The version of the ATTUNE tibial component examined in this study has subsequently undergone modification by the manufacturer.Development and application of statistical models for medical scientific researc
    corecore