13 research outputs found

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    Socioeconomic impact on device-associated infections in limited-resource neonatal intensive care units: findings of the INICC

    No full text
    Purpose To evaluate the impact of country socioeconomic status and hospital type on device-associated healthcare-associated infections (DA-HAIs) in neonatal intensive care units (NICUs). Methods Data were collected on DA-HAIs from September 2003 to February 2010 on 13,251 patients in 30 NICUs in 15 countries. DA-HAIs were defined using criteria formulated by the Centers for Disease Control and Prevention. Country socioeconomic status was defined using World Bank criteria. Results Central-line-associated bloodstream infection (CLA-BSI) rates in NICU patients were significantly lower in private than academic hospitals (10.8 vs. 14.3 CLA-BSI per 1,000 catheter-days; p < 0.03), but not different in public and academic hospitals (14.6 vs. 14.3 CLA-BSI per 1,000 catheter-days; p = 0.86). NICU patient CLA-BSI rates were significantly higher in low-income countries than in lower-middle-income countries or upper-middle-income countries [37.0 vs. 11.9 (p < 0.02) vs. 17.6 (p < 0.05) CLA-BSIs per 1,000 catheter-days, respectively]. Ventilator-associated-pneumonia (VAP) rates in NICU patients were significantly higher in academic hospitals than in private or public hospitals [13.2 vs. 2.4 (p < 0.001) vs. 4.9 (p < 0.001) VAPs per 1,000 ventilator days, respectively]. Lower-middle-income countries had significantly higher VAP rates than low-income countries (11.8 vs. 3.8 per 1,000 ventilator-days; p < 0.001), but VAP rates were not different in low-income countries and upper-middle-income countries (3.8 vs. 6.7 per 1,000 ventilator-days; p = 0.57). When examined by hospital type, overall crude mortality for NICU patients without DA-HAIs was significantly higher in academic and public hospitals than in private hospitals (5.8 vs. 12.5%; p < 0.001). In contrast, NICU patient mortality among those with DA-HAIs was not different regardless of hospital type or country socioeconomic level. Conclusions Hospital type and country socioeconomic level influence DA-HAI rates and overall mortality in developing countries

    Impact of a multidimensional infection control strategy on central line-associated bloodstream infection rates in pediatric intensive care units of five developing countries: findings of the International Nosocomial Infection Control Consortium (INICC)

    No full text
    To analyze the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional infection control strategy including a practice bundle to reduce the rates of central line-associated bloodstream infection (CLAB) in patients hospitalized in pediatric intensive care units (PICUs) of hospitals, which are members of the INICC, from nine cities of five developing countries: Colombia, India, Mexico, Philippines, and Turkey. CLAB rates were determined by means of a prospective surveillance study conducted on 1,986 patients hospitalized in nine PICUs, over a period of 12,774 bed-days. The study was divided into two phases. During Phase 1 (baseline period), active surveillance was performed without the implementation of the multi-faceted approach. CLAB rates obtained in Phase 1 were compared with CLAB rates obtained in Phase 2 (intervention period), after implementation of the INICC multidimensional infection control program. During Phase 1, 1,029 central line (CL) days were recorded, and during Phase 2, after implementing the CL care bundle and interventions, we recorded 3,861 CL days. The CLAB rate was 10.7 per 1,000 CL days in Phase 1, and in Phase 2, the CLAB rate decreased to 5.2 per 1,000 CL days (relative risk [RR] 0.48, 95% confidence interval [CI] 0.29-0.94, P = 0.02), showing a reduction of 52% in the CLAB rate. This study shows that the implementation of a multidimensional infection control strategy was associated with a significant reduction in the CLAB rates in the PICUs of developing countries

    Nosocomial Infection Control Consortium (INICC)

    No full text
    We aimed to evaluate the impact of a multidimensional infection control strategy for the reduction of the incidence of catheter-associated urinary tract infection (CAUTI) in patients hospitalized in adult intensive care units (AICUs) of hospitals which are members of the International Nosocomial Infection Control Consortium (INICC), from 40 cities of 15 developing countries: Argentina, Brazil, China, Colombia, Costa Rica, Cuba, India, Lebanon, Macedonia, Mexico, Morocco, Panama, Peru, Philippines, and Turkey.We conducted a prospective before-after surveillance study of CAUTI rates on 56,429 patients hospitalized in 57 AICUs, during 360,667 bed-days. The study was divided into the baseline period (Phase 1) and the intervention period (Phase 2). In Phase 1, active surveillance was performed. In Phase 2, we implemented a multidimensional infection control approach that included: (1) a bundle of preventive measures, (2) education, (3) outcome surveillance, (4) process surveillance, (5) feedback of CAUTI rates, and (6) feedback of performance. The rates of CAUTI obtained in Phase 1 were compared with the rates obtained in Phase 2, after interventions were implemented.We recorded 253,122 urinary catheter (UC)-days: 30,390 in Phase 1 and 222,732 in Phase 2. In Phase 1, before the intervention, the CAUTI rate was 7.86 per 1,000 UC-days, and in Phase 2, after intervention, the rate of CAUTI decreased to 4.95 per 1,000 UC-days [relative risk (RR) 0.63 (95 % confidence interval [CI] 0.55-0.72)], showing a 37 % rate reduction.Our study showed that the implementation of a multidimensional infection control strategy is associated with a significant reduction in the CAUTI rate in AICUs from developing countries

    Findings of the International Nosocomial Infection Control Consortium (INICC), Part I: Effectiveness of a Multidimensional Infection Control Approach on Catheter-Associated Urinary Tract Infection Rates in Pediatric Intensive Care Units of 6 Developing Countries

    No full text
    DESIGN. A before-after prospective surveillance study to assess the impact of a multidimensional infection control approach for the reduction of catheter-associated urinary tract infection (CAUTI) rates. SETTING. Pediatric intensive care units (PICUs) of hospital members of the International Nosocomial Infection Control Consortium (INICC) from 10 cities of the following 6 developing countries: Colombia, El Salvador, India, Mexico, Philippines, and Turkey. PATIENTS. PICU inpatients. METHODS. We performed a prospective active surveillance to determine rates of CAUTI among 3,877 patients hospitalized in 10 PICUs for a total of 27,345 bed-days. The study was divided into a baseline period (phase 1) and an intervention period (phase 2). In phase 1, surveillance was performed without the implementation of the multidimensional approach. In phase 2, we implemented a multidimensional infection control approach that included outcome surveillance, process surveillance, feedback on CAUTI rates, feedback on performance, education, and a bundle of preventive measures. The rates of CAUTI obtained in phase 1 were compared with the rates obtained in phase 2, after interventions were implemented. RESULTS. During the study period, we recorded 8,513 urinary catheter (UC) days, including 1,513 UC-days in phase 1 and 7,000 UCdays in phase 2. In phase 1, the CAUTI rate was 5.9 cases per 1,000 UC-days, and in phase 2, after implementing the multidimensional infection control approach for CAUTI prevention, the rate of CAUTI decreased to 2.6 cases per 1,000 UC-days (relative risk, 0.43 [95% confidence interval, 0.21-1.0]), indicating a rate reduction of 57%. CONCLUSIONS. Our findings demonstrated that implementing a multidimensional infection control approach is associated with a significant reduction in the CAUTI rate of PICUs in developing countries. Infect Control Hosp Epidemiol 2012;33(7):696-70
    corecore