50 research outputs found

    Left pneumonectomy for rapidly growing lung metastasis from phyllodes tumor

    Get PDF
    Distant metastases occur in 10-25% of malignant phyllodes tumors of the breast, heralding fatal outcome within few months. Only four cases of successful resection of solitary pulmonary metastases from phyllodes tumor are described in the literature. We report the case of a 67-year-old woman who developed rapidly growing metastases (volume doubling time: 25 days) in the left lung, two years after mastectomy for malignant phyllodes tumor. The left lung was the only site of 18-FDG uptake at total-body PET scan and the patient was successfully treated by left pneumonectomy

    Peri-operative complications of video-assisted thoracoscopic surgery (VATS)

    Get PDF
    AbstractVideo-assisted thoracoscopic surgery (VATS) has multiple indications for diagnosis and treatment of many different thoracic diseases; the commonest are lung wedge resection, pleural and mediastinal biopsy, treatment of pneumothorax, and pleurectomy. Moreover, in recent years a few surgeons have performed routinely major lung anatomic resections by VATS approach, including segmentectomy, lobectomy and pneumonectomy.In our experience VATS constitutes about one-third of all thoracic surgical procedures. In the reviewed literature as in the most frequent complications after VATS procedures are: prolonged air leak, bleeding, infection, postoperative pain, port site recurrence and the need to convert the access in thoracotomy. The complication and mortality rates are generally very low and VATS procedures are considered safe and effective.It is recommended that all thoracic surgery departments audit their VATS procedures for peri-operative morbidity and mortality to compare results and outcomes

    Bronchogenic cyst associated with pericardial defect: Case report and review of the literature

    Get PDF
    Partial defect of the pericardium combined with bronchogenic cyst is a very rare congenital anomaly. We describe the case of a 32-year-old man with a partial defect of the left pericardium and a bronchogenic cyst arising from the border of the pericardial defect. The cyst was successfully resected with the harmonic scalpel by three-port videothoracoscopic approach

    Towards a muon collider

    Get PDF
    A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work

    Towards a Muon Collider

    Full text link
    A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work.Comment: 118 pages, 103 figure

    Erratum:Towards a muon collider

    Get PDF

    Towards a muon collider

    Get PDF
    A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work

    Erratum: Towards a muon collider

    Get PDF
    The original online version of this article was revised: The additional reference [139] has been added. Tao Han’s ORICD ID has been incorrectly assigned to Chengcheng Han and Chengcheng Han’s ORCID ID to Tao Han. Yang Ma’s ORCID ID has been incorrectly assigned to Lianliang Ma, and Lianliang Ma’s ORCID ID to Yang Ma. The original article has been corrected

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM
    corecore