409 research outputs found
Out-of-hours care in western countries: assessment of different organizational models
Contains fulltext :
81655.pdf (publisher's version ) (Open Access)BACKGROUND: Internationally, different organizational models are used for providing out-of-hours care. The aim of this study was to assess prevailing models in order to identify their potential strengths and weaknesses. METHODS: An international web-based survey was done in 2007 in a sample of purposefully selected key informants from 25 western countries. The questions concerned prevailing organizational models for out-of-hours care, the most dominant model in each country, perceived weaknesses, and national plans for changes in out-of-hours care. RESULTS: A total of 71 key informants from 25 countries provided answers. In most countries several different models existed alongside each other. The Accident and Emergency department was the organizational model most frequently used. Perceived weaknesses of this model concerned the coordination and continuity of care, its efficiency and accessibility. In about a third of the countries, the rota group was the most dominant organizational model for out-of-hours care. A perceived weakness of this model was lowered job satisfaction of physicians. The GP cooperative existed in a majority of the participating countries; no weaknesses were mentioned with respect to this model. Most of the countries had plans to change the out-of-hours care, mainly toward large scale organizations. CONCLUSION: GP cooperatives combine size of scale advantages with organizational features of strong primary care, such as high accessibility, continuity and coordination of care. While specific patients require other organizational models, the co-existence of different organizational models for out-of-hours care in a country may be less efficient for health systems
Recommended from our members
SEIS: Insight's Seismic Experiment for Internal Structure of Mars.
By the end of 2018, 42 years after the landing of the two Viking seismometers on Mars, InSight will deploy onto Mars' surface the SEIS (Seismic Experiment for Internal Structure) instrument; a six-axes seismometer equipped with both a long-period three-axes Very Broad Band (VBB) instrument and a three-axes short-period (SP) instrument. These six sensors will cover a broad range of the seismic bandwidth, from 0.01 Hz to 50 Hz, with possible extension to longer periods. Data will be transmitted in the form of three continuous VBB components at 2 sample per second (sps), an estimation of the short period energy content from the SP at 1 sps and a continuous compound VBB/SP vertical axis at 10 sps. The continuous streams will be augmented by requested event data with sample rates from 20 to 100 sps. SEIS will improve upon the existing resolution of Viking's Mars seismic monitoring by a factor of ∼ 2500 at 1 Hz and ∼ 200 000 at 0.1 Hz. An additional major improvement is that, contrary to Viking, the seismometers will be deployed via a robotic arm directly onto Mars' surface and will be protected against temperature and wind by highly efficient thermal and wind shielding. Based on existing knowledge of Mars, it is reasonable to infer a moment magnitude detection threshold of M w ∼ 3 at 40 ∘ epicentral distance and a potential to detect several tens of quakes and about five impacts per year. In this paper, we first describe the science goals of the experiment and the rationale used to define its requirements. We then provide a detailed description of the hardware, from the sensors to the deployment system and associated performance, including transfer functions of the seismic sensors and temperature sensors. We conclude by describing the experiment ground segment, including data processing services, outreach and education networks and provide a description of the format to be used for future data distribution.Electronic supplementary materialThe online version of this article (10.1007/s11214-018-0574-6) contains supplementary material, which is available to authorized users
FIGS-Faint Infrared Grism Survey: Description and Data Reduction
The Faint Infrared Grism Survey (FIGS) is a deep Hubble Space Telescope (HST) WFC3/IR (Wide Field Camera 3 Infrared) slitless spectroscopic survey of four deep fields. Two fields are located in the Great Observatories Origins Deep Survey-North (GOODS-N) area and two fields are located in the Great Observatories Origins Deep Survey-South (GOODS-S) area. One of the southern fields selected is the Hubble Ultra Deep Field. Each of these four fields were observed using the WFC3/G102 grism (0.8 μm–1.15 μm continuous coverage) with a total exposure time of 40 orbits (≈100 kilo-seconds) per field. This reaches a continuum depth of AB magnitudes and probes emission lines to . This paper details the four FIGS fields and the overall observational strategy of the project. A detailed description of the Simulation Based Extraction (SBE) method used to extract and combine over 10,000 spectra of over 2000 distinct sources brighter than mag is provided. High fidelity simulations of the observations is shown to significantly improve the background subtraction process, the spectral contamination estimates, and the final flux calibration. This allows for the combination of multiple spectra to produce a final high quality, deep, 1D spectra for each object in the survey
Mapping the contribution of β3-containing GABA(A )receptors to volatile and intravenous general anesthetic actions
BACKGROUND: Agents belonging to diverse chemical classes are used clinically as general anesthetics. The molecular targets mediating their actions are however still only poorly defined. Both chemical diversity and substantial differences in the clinical actions of general anesthetics suggest that general anesthetic agents may have distinct pharmacological targets. It was demonstrated previously that the immobilizing action of etomidate and propofol is completely, and the immobilizing action of isoflurane partly mediated, by β3-containing GABA(A )receptors. This was determined by using the β3(N265M) mice, which carry a point mutation known to decrease the actions of general anesthetics at recombinant GABA(A )receptors. In this communication, we analyzed the contribution of β3-containing GABA(A )receptors to the pharmacological actions of isoflurane, etomidate and propofol by means of β3(N265M) mice. RESULTS: Isoflurane decreased core body temperature and heart rate to a smaller degree in β3(N265M) mice than in wild type mice, indicating a minor but significant role of β3-containing GABA(A )receptors in these actions. Prolonged time intervals in the ECG and increased heart rate variability were indistinguishable between genotypes, suggesting no involvement of β3-containing GABA(A )receptors. The anterograde amnesic action of propofol was indistinguishable in β3(N265M) and wild type mice, suggesting that it is independent of β3-containing GABA(A )receptors. The increase of heart rate variability and prolongation of ECG intervals by etomidate and propofol were also less pronounced in β3(N265M) mice than in wild type mice, pointing to a limited involvement of β3-containing GABA(A )receptors in these actions. The lack of etomidate- and propofol-induced immobilization in β3(N265M) mice was also observed in congenic 129X1/SvJ and C57BL/6J backgrounds, indicating that this phenotype is stable across different backgrounds. CONCLUSION: Our results provide evidence for a defined role of β3-containing GABA(A )receptors in mediating some, but not all, of the actions of general anesthetics, and confirm the multisite model of general anesthetic action. This pharmacological separation of anesthetic endpoints also suggests that subtype-selective substances with an improved side-effect profile may be developed
Effective Rheology of Bubbles Moving in a Capillary Tube
We calculate the average volumetric flux versus pressure drop of bubbles
moving in a single capillary tube with varying diameter, finding a square-root
relation from mapping the flow equations onto that of a driven overdamped
pendulum. The calculation is based on a derivation of the equation of motion of
a bubble train from considering the capillary forces and the entropy production
associated with the viscous flow. We also calculate the configurational
probability of the positions of the bubbles.Comment: 4 pages, 1 figur
Taurolidine-citrate lock solution (TauroLock) significantly reduces CVAD-associated grampositive infections in pediatric cancer patients
<p>Abstract</p> <p>Background</p> <p>Taurolidin/Citrate (TauroLock™), a lock solution with broad spectrum antimicrobial activity, may prevent bloodstream infection (BSI) due to coagulase-negative staphylococci (CoNS or 'MRSE' in case of methicillin-resistant isolates) in pediatric cancer patients with a long term central venous access device (CVAD, Port- or/Broviac-/Hickman-catheter type).</p> <p>Methods</p> <p>In a single center prospective 48-months cohort study we compared all patients receiving anticancer chemotherapy from April 2003 to March 2005 (group 1, heparin lock with 200 IU/ml sterile normal saline 0.9%; Canusal<sup>® </sup>Wockhardt UK Ltd, Wrexham, Wales) and all patients from April 2005 to March 2007 (group 2; taurolidine 1.35%/Sodium Citrate 4%; TauroLock™, Tauropharm, Waldbüttelbrunn, Germany).</p> <p>Results</p> <p>In group 1 (heparin), 90 patients had 98 CVAD in use during the surveillance period. 14 of 30 (47%) BSI were 'primary Gram positive BSI due to CoNS (n = 4) or MRSE (n = 10)' [incidence density (ID); 2.30 per 1000 inpatient CVAD-utilization days].</p> <p>In group 2 (TauroLock™), 89 patients had 95 CVAD in use during the surveillance period. 3 of 25 (12%) BSI were caused by CoNS. (ID, 0.45). The difference in the ID between the two groups was statistically significant (P = 0.004).</p> <p>Conclusion</p> <p>The use of Taurolidin/Citrate (TauroLock™) significantly reduced the number and incidence density of primary catheter-associated BSI due to CoNS and MRSE in pediatric cancer patients.</p
Clinical and epidemiological aspects of a hepatitis E outbreak in Bangui, Central African Republic
<p>Abstract</p> <p>Background</p> <p>Outbreaks of hepatitis E frequently occur in tropical developing countries during the rainy season due to overflowing drains, short-circuiting of networks of clean water and use of contaminated water from wells. Hepatitis E virus (HEV) infections are usually accompanied by general symptoms of acute liver disease. This study was conducted to define the clinical and epidemiological aspects of the HEV outbreak that occurred in May 2004 in Bangui.</p> <p>Methods</p> <p>Blood samples were collected from 411 patients aged 1-87 years, most of whom presented with jaundice, asthenia or signs of uncomplicated malaria, for a transversal study from June 2004 to September 2005. Patients were recruited at 11 health care centres, including two referral hospitals, after they had given informed consent. The diagnosis of HEV was made with a commercial ELISA test to detect IgM and/or IgG antibodies. HEV RNA was amplified by RT-PCR to confirm the presence of the viral genome.</p> <p>Results</p> <p>The most frequent clinical signs found were jaundice (93.4%), vomiting (50.7%), hepatalgia (47.4%), hepatomegaly (30.9%) and asthenia (26.8%), which are the general clinical signs of hepatic disease. Acute hepatitis E was found in 213 patients (51.8%) who were positive for HEV IgM antibodies. The IgG anti-HEV seroprevalence during this outbreak was high (79.5%). The age group 18-34 years was more frequently infected (91.2%) than those aged 1-17 (78.0%) or over 34 (64.9%) (p < 10<sup>-6</sup>). RT-PCR performed on 127 sera from the 213 IgM-HEV-positive patients was amplified, and the presence of the viral genome was found in 65 samples.</p> <p>Conclusion</p> <p>Although no specific clinical signs exist for hepatitis E infection, people presenting with jaundice, vomiting, hepatalgia, asthenia, hepatomegaly or distended abdomen with no signs of uncomplicated malaria in tropical developing countries should be sent to a laboratory for testing for hepatitis E.</p
ContextD: an algorithm to identify contextual properties of medical terms in a Dutch clinical corpus
- …