48 research outputs found

    Hourly land-use regression models based on low-cost PM monitor data

    Get PDF
    Land-use regression (LUR) models provide location and time specific estimates of exposure to air pollution and thereby improve the sensitivity of health effects models. However, they require pollutant concentrations at multiple locations along with land-use variables. Often, monitoring is performed over short durations using mobile monitoring with research-grade instruments. Low-cost PM monitors provide an alternative approach that increases the spatial and temporal resolution of the air quality data. LUR models were developed to predict hourly PM concentrations across a metropolitan area using PM concentrations measured simultaneously at multiple locations with low-cost monitors. Monitors were placed at 23 sites during the 2015/16 heating season. Monitors were externally calibrated using co-located measurements including a reference instrument (GRIMM particle spectrometer). LUR models for each hour of the day and weekdays/weekend days were developed using the deletion/substitution/addition algorithm. Coefficients of determination for hourly PM predictions ranged from 0.66 and 0.76 (average 0.7). The hourly-resolved LUR model results will be used in epidemiological studies to examine if and how quickly, increases in ambient PM concentrations trigger adverse health events by reducing the exposure misclassification that arises from using less time resolved exposure estimates

    Residential Indoor and Outdoor PM Measured Using Low-cost Monitors during the Heating Season in Monroe County, NY

    Get PDF
    Continuous 1-minute indoor and outdoor PM concentrations (~PM2.5) were measured from November through April of 2015/16 and 2016/17 at 50 single family residences in Monroe County, NY (25 per season) using Speck (Airviz Inc., Pittsburgh, PA) low-cost monitors (LCMs). While the accuracy of LCMs is inconsistent and source dependent, the LCMs provided reasonable precision for estimating indoor/outdoor (I/O) ratios based on laboratory and field testing, understanding the relationship between indoor sources and concentration, and comparing PM concentrations across residences for the detected size range (0.5-3 mm). The indoor PM2.5 concentration pattern showed clear morning and evening peaks as well as higher indoor concentrations during the weekends when people are typically at home. The mean I/O PM2.5 ratio was 1.1 for all homes and increased to 1.7 when a combustion source was in use as indicated by an elevated CO concentration whereas most prior studies have found this ratio to be < 1. Increases in wood-burning appliance temperature and indoor CO concentrations were found to be associated with an overall moderate (mean value of 2.1 µg/m3) increase in indoor PM concentration averaged over the heating season. Short-term PM increases greater than 100 µg/m3 were periodically observed in homes with and without wood-burning appliances operating. This study provides an approach for exposure assessment in homes that can be utilized by employing appropriate calibration and quality assurance procedures for the LCMs

    Phenomenology of ultrafine particle concentrations and size distribution across urban Europe

    Get PDF
    The 2017-2019 hourly particle number size distributions (PNSD) from 26 sites in Europe and 1 in the US were evaluated focusing on 16 urban background (UB) and 6 traffic (TR) sites in the framework of Research Infrastructures services reinforcing air quality monitoring capacities in European URBAN & industrial areaS (RI-URBANS) project. The main objective was to describe the phenomenology of urban ultrafine particles (UFP) in Europe with a significant air quality focus. The varying lower size detection limits made it difficult to compare PN concentrations (PNC), particularly PN10-25, from different cities. PNCs follow a TR > UB > Suburban (SUB) order. PNC and Black Carbon (BC) progressively increase from Northern Europe to Southern Europe and from Western to Eastern Europe. At the UB sites, typical traffic rush hour PNC peaks are evident, many also showing midday-morning PNC peaks anti-correlated with BC. These peaks result from increased PN10-25, suggesting significant PNC contributions from nucleation, fumigation and shipping. Site types to be identified by daily and seasonal PNC and BC patterns are: (i) PNC mainly driven by traffic emissions, with marked correlations with BC on different time scales; (ii) marked midday/morning PNC peaks and a seasonal anti-correlation with PNC/BC; (iii) both traffic peaks and midday peaks without marked seasonal patterns. Groups (ii) and (iii) included cities with high insolation. PNC, especially PN25-800, was positively correlated with BC, NO2, CO and PM for several sites. The variable correlation of PNSD with different urban pollutants demonstrates that these do not reflect the variability of UFP in urban environments. Specific monitoring of PNSD is needed if nanoparticles and their associated health impacts are to be assessed. Implementation of the CEN-ACTRIS recommendations for PNSD measurements would provide comparable measurements, and measurements of <10 nm PNC are needed for full evaluation of the health effects of this size fraction

    Term birth weight and ambient air pollutant concentrations during pregnancy, among women living in Monroe County, New York

    Get PDF
    Increased ambient air pollutant concentrations during pregnancy have been associated with reduced birth weight, but the etiologically relevant pregnancy time window(s) is/are unclear. In 76,500 singleton births in Monroe County, NY (2005–2016), who were 37–42 gestational weeks at delivery, we used generalized linear models to regress term birth weight against mean gestational month pollutant concentrations, adjusting for mean temperature, and maternal, infant, and medical service use characteristics. Overall, there were no clear patterns of term birth weight change associated with increased concentrations of any pollutant across gestational months. However, among Hispanic women only, increases in all pollutants, except O3, in multiple gestational months, were associated with decreased term birth weight. Each 3.25 µg/m3 increase in PM2.5 concentration in the 6th gestational month was associated with a −20.4 g (95% CI = −34.0, −6.8) reduction in term birth weight among Hispanic women, but a 4.1 g (95% CI = −2.5, 10.8) increase among non-Hispanic mothers (p for interaction &lt; 0.001). Although ambient air pollutant concentrations during pregnancy were not associated with reduced term birth weight among women of all ethnicities living in Monroe County, this observed association in Hispanic mothers may be a result of less exposure misclassification and bias (due to closer residential proximity to the monitoring site)

    Primary Versus Secondary Contributions to Particle Number Concentrations in the European Boundary Layer

    Get PDF
    It is important to understand the relative contribution of primary and secondary particles to regional and global aerosol so that models can attribute aerosol radiative forcing to different sources. In large-scale models, there is considerable uncertainty associated with treatments of particle formation (nucleation) in the boundary layer (BL) and in the size distribution of emitted primary particles, leading to uncertainties in predicted cloud condensation nuclei (CCN) concentrations. Here we quantify how primary particle emissions and secondary particle formation influence size-resolved particle number concentrations in the BL using a global aerosol microphysics model and aircraft and ground site observations made during the May 2008 campaign of the European Integrated Project on Aerosol Cloud Climate Air Quality Interactions (EUCAARI). We tested four different parameterisations for BL nucleation and two assumptions for the emission size distribution of anthropogenic and wildfire carbonaceous particles. When we emit carbonaceous particles at small sizes (as recommended by the Aerosol Intercomparison project, AEROCOM), the spatial distributions of campaign-mean number concentrations of particles with diameter >50 nm (N50) and >100 nm (N100) were well captured by the model (R2≥0.8) and the normalised mean bias (NMB) was also small (−18% for N50 and −1% for N100). Emission of carbonaceous particles at larger sizes, which we consider to be more realistic for low spatial resolution global models, results in equally good correlation but larger bias (R2≥0.8, NMB = −52% and −29%), which could be partly but not entirely compensated by BL nucleation. Within the uncertainty of the observations and accounting for the uncertainty in the size of emitted primary particles, BL nucleation makes a statistically significant contribution to CCN-sized particles at less than a quarter of the ground sites. Our results show that a major source of uncertainty in CCN-sized particles in polluted European air is the emitted size of primary carbonaceous particles. New information is required not just from direct observations, but also to determine the "effective emission size" and composition of primary particles appropriate for different resolution models.JRC.H.2-Air and Climat

    The F0F1-ATP Synthase Complex Contains Novel Subunits and Is Essential for Procyclic Trypanosoma brucei

    Get PDF
    The mitochondrial F0F1 ATP synthase is an essential multi-subunit protein complex in the vast majority of eukaryotes but little is known about its composition and role in Trypanosoma brucei, an early diverged eukaryotic pathogen. We purified the F0F1 ATP synthase by a combination of affinity purification, immunoprecipitation and blue-native gel electrophoresis and characterized its composition and function. We identified 22 proteins of which five are related to F1 subunits, three to F0 subunits, and 14 which have no obvious homology to proteins outside the kinetoplastids. RNAi silencing of expression of the F1 α subunit or either of the two novel proteins showed that they are each essential for the viability of procyclic (insect stage) cells and are important for the structural integrity of the F0F1-ATP synthase complex. We also observed a dramatic decrease in ATP production by oxidative phosphorylation after silencing expression of each of these proteins while substrate phosphorylation was not severely affected. Our procyclic T. brucei cells were sensitive to the ATP synthase inhibitor oligomycin even in the presence of glucose contrary to earlier reports. Hence, the two novel proteins appear essential for the structural organization of the functional complex and regulation of mitochondrial energy generation in these organisms is more complicated than previously thought

    Highly Divergent Mitochondrial ATP Synthase Complexes in Tetrahymena thermophila

    Get PDF
    Tetrahymena ATP synthase, an evolutionarily divergent protein complex, has a very unusual structure and protein composition including a unique Fo subunit a and at least 13 proteins with no orthologs outside of the ciliate lineage

    Ultrafine particles in four European urban environments: Results from a new continuous long-term monitoring network

    Get PDF
    To gain a better understanding on the spatiotemporal variation of ultrafine particles (UFPs) in urban environments, this study reports on the first results of a long-term UFP monitoring network, set up in Amsterdam (NL), Antwerp (BE), Leicester (UK) and London (UK). Total number concentrations and size distributions were assessed during 1e2 years at four fixed urban background sites, supplemented with mobile trailer measurements for co-location monitoring and additional short-term monitoring sites. Intra- and interurban spatiotemporal UFP variation, associations with commonly-monitored pollutants (PM, NOx and BC) and impacts of wind fields were evaluated. Although comparable size distributions were observed between the four cities, source-related differences were demonstrated within specific particle size classes. Total and size-resolved particle number concentrations showed clear traffic-related temporal variation, confirming road traffic as the major UFP contributor in urban environments. New particle formation events were observed in all cities. Correlations with typical traffic-related pollutants (BC and NOx) were obtained for all monitoring stations, except for Amsterdam, which might be attributable to UFP emissions from Schiphol airport. The temporal variation in particle number concentration correlated fairly weakly between the four cities (rs = 0.28 0.50, COD = 0.28 0.37), yet improved significantly inside individual cities (rs = 0.59-0.77). Nevertheless, considerable differences were still obtained in terms of particle numbers (20-38% for total particle numbers and up to 49% for size-resolved particle numbers), confirming the importance of local source contributions and the need for careful consideration when allocating UFP monitoring stations in heterogeneous urban environments

    Mitochondrial respiratory states and rate

    Get PDF
    As the knowledge base and importance of mitochondrial physiology to human health expands, the necessity for harmonizing the terminologyconcerning mitochondrial respiratory states and rates has become increasingly apparent. Thechemiosmotic theoryestablishes the mechanism of energy transformationandcoupling in oxidative phosphorylation. Theunifying concept of the protonmotive force providestheframeworkfordeveloping a consistent theoretical foundation ofmitochondrial physiology and bioenergetics.We followguidelines of the International Union of Pure and Applied Chemistry(IUPAC)onterminology inphysical chemistry, extended by considerationsofopen systems and thermodynamicsof irreversible processes.Theconcept-driven constructive terminology incorporates the meaning of each quantity and alignsconcepts and symbols withthe nomenclature of classicalbioenergetics. We endeavour to provide a balanced view ofmitochondrial respiratory control and a critical discussion on reporting data of mitochondrial respiration in terms of metabolic flows and fluxes.Uniform standards for evaluation of respiratory states and rates will ultimatelycontribute to reproducibility between laboratories and thussupport the development of databases of mitochondrial respiratory function in species, tissues, and cells.Clarity of concept and consistency of nomenclature facilitate effective transdisciplinary communication, education, and ultimately further discovery
    corecore