31 research outputs found

    Submersed Micropatterned Structures Control Active Nematic Flow, Topology and Concentration

    Get PDF
    Coupling between flows and material properties imbues rheological matter with its wide-ranging applicability, hence the excitement for harnessing the rheology of active fluids for which internal structure and continuous energy injection lead to spontaneous flows and complex, out-of-equilibrium dynamics. We propose and demonstrate a convenient, highly tuneable method for controlling flow, topology and composition within active films. Our approach establishes rheological coupling via the indirect presence of fully submersed micropatterned structures within a thin, underlying oil layer. Simulations reveal that micropatterned structures produce effective virtual boundaries within the superjacent active nematic film due to differences in viscous dissipation as a function of depth. This accessible method of applying position-dependent, effective dissipation to the active films presents a non-intrusive pathway for engineering active microfluidic systems.Comment: 13 pages; 5 main-text-figures; 3-supplemental-figure

    Aortic root surgery in septuagenarians: impact of different surgical techniques

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the impact and safety of different surgical techniques for aortic root replacement (ARR) on early and late morbidity and mortality in septuagenarians undergoing ARR.</p> <p>Methods</p> <p>Ninety-five patients (73.8 ± 3.2 years) were operated and divided into three groups according to the aortic root procedure; MECH-group (n = 51) patients with a mechanical composite graft, BIO-group (n = 22) patients with a customized biological composite graft, and REIMPL-group (n = 22) patients with a valve sparing aortic root reimplantation (David I). In 42.1% (40/95) of these patients the aortic arch was replaced. Follow-up was completed in 95.2% (79/83) of in-hospital survivors.</p> <p>Results</p> <p>Hospital mortality was 12.6% (12/95) in the entire population (MECH. 15.7% (8/51), BIO 19.7% (4/22), REIMPL 0% (0/22); p = 0.004). Two patients died intraoperatively. The most frequent postoperative complications were prolonged mechanical ventilation ((>48 h) in 16.8% (16/93) (MECH. 7% (7/51), BIO 36.4% (8/22), REIMPL 4.5% (1/22); p = 0.013) and rethoracotomy for postoperative bleeding in 12.6% (12/95) (MECH. 12% (6/51), BIO 22.7% (5/22), REIMPL 4.5% (1/22); p = 0.19). Nineteen late deaths (22.9%) (19/83) (MECH 34.8% (15/43), BIO 16.7% (3/18), REIMPL 4.5% (1/22); p = 0.012) occurred during a mean follow-up of 41 ± 42 months (MECH 48 ± 48 months, BIO 25 ± 37 months, REIMPL 40 ± 28 months, p = 0.028). Postoperative NYHA class decreased significantly (p = 0.017) and performance status (p = 0.027) increased for the entire group compared to preoperative values.</p> <p>Conclusion</p> <p>Our data indicate that valve sparing aortic root reimplantation is safe and effective in septuagenarians, and is associated with low early and late morbidity and mortality.</p

    A Novel Microwave Sensor to Detect Specific Biomarkers in Human Cerebrospinal Fluid and Their Relationship to Cellular Ischemia During Thoracoabdominal Aortic Aneurysm Repair

    Get PDF
    Thoraco-abdominal aneurysms (TAAA) represents a particularly lethal vascular disease that without surgical repair carries a dismal prognosis. However, there is an inherent risk from surgical repair of spinal cord ischaemia that can result in paraplegia. One method of reducing this risk is cerebrospinal fluid (CSF) drainage. We believe that the CSF contains clinically significant biomarkers that can indicate impending spinal cord ischaemia. This work therefore presents a novel measurement method for proteins, namely albumin, as a precursor to further work in this area. The work uses an interdigitated electrode (IDE) sensor and shows that it is capable of detecting various concentrations of albumin (from 0 to 100 g/L) with a high degree of repeatability at 200 MHz (R2 = 0.991) and 4 GHz (R2 = 0.975)

    Brief review on systematic hypothermia for the protection of central nervous system during aortic arch surgery: a double-sword tool?

    Get PDF
    Antegrade selective cerebral perfusion in conjunction with hypothermia attenuate postoperative neurological injury, which in turn still remains the main cause of mortality and morbidity following aortic arch surgery. Hypothermic circulatory arrest however could be a useful tool during arch surgery, surgery for chronic thromboembolic disease, air on the arterial line during CPB, during cavotomy for extraction of renal cell carcinoma with level IV extension, or when dealing with difficult trauma to the SVC or IVC. Cerebral protective effects with hypothermic procedures including inhibition of neuron excitation, and discharge of excitable amino acids, and thereby, prevention of an increase in intercellular calcium ions, hyperoxidation of lipids in cell membranes, and free radical production

    Biomarkers for Severity of Spinal Cord Injury in the Cerebrospinal Fluid of Rats

    Get PDF
    One of the major challenges in management of spinal cord injury (SCI) is that the assessment of injury severity is often imprecise. Identification of reliable, easily quantifiable biomarkers that delineate the severity of the initial injury and that have prognostic value for the degree of functional recovery would significantly aid the clinician in the choice of potential treatments. To find such biomarkers we performed quantitative liquid chromatography-mass spectrometry (LC-MS/MS) analyses of cerebrospinal fluid (CSF) collected from rats 24 h after either a moderate or severe SCI. We identified a panel of 42 putative biomarkers of SCI, 10 of which represent potential biomarkers of SCI severity. Three of the candidate biomarkers, Ywhaz, Itih4, and Gpx3 were also validated by Western blot in a biological replicate of the injury. The putative biomarkers identified in this study may potentially be a valuable tool in the assessment of the extent of spinal cord damage

    Lympho-szintigraphische Lokalisation einer high-output Chylus-Leckage mittels SPECT/CT

    No full text

    Transplanted human cord blood derived unrestricted somatic stem cells improve left-ventricular function and prevent left-ventricular dilation and scar formation after acute myocardial infarction

    No full text
    Objectives: Human unrestricted somatic stem cells [USSC] are newly discovered cord blood-derived cells with pluripotent differentiation potential. We aimed to assess whether intra- myocardial transfer of USSC would improve global left- ventricular function in a porcine model of myocardial infarction [MI]. Methods: USSC were isolated from cord blood [CB] of the umbilical cord vein. 13×10 6 cells were transplanted into the acutely ischemic lateral wall of the left ventricle (n=5). Control animals (n=5) received medium injection. LV dimension and function were assessed by transesophageal echocardiography [TEE] immediately before MI, after MI followed by cell transplantation and after 8 weeks. The hearts were examined for cell survival, cardiac differentiation and scar formation. Results: Global LVEF after MI was 32±8% in controls and 36±9% in the cell treated group. After 2 months, mean global LVEF had decreased to 27±5% in the control group and increased to 52±2% in the cell treated group (p<0.01). Left- ventricular end-diastolic volume [LVEDV] after two months was 77±4ml in the control group compared to 26±2ml in the cord blood group (p<0.01). Myocardial scar was present only in the control group. Conclusion: Transplantation of USSC after myocardial infarction significantly improves LV function, reduces infarct size and prevents LV dilation

    Aortic valve stenosis after previous coronary bypass: Transcatheter valve implantation or aortic valve replacement?

    Get PDF
    <p>Abstract</p> <p>We report a prospective comparison between transcatheter valve implantation (TAVI, n = 13) and surgical aortic valve replacement (AVR, n = 10) in patients with severe aortic valve stenosis and previous coronary bypass surgery (CABG). All patients had at least bilateral patent internal thoracic arteries bypass without indication of repeat revascularization. After a similar post-procedure outcome, despite one early death in TAVI group, the 1-year survival was 100% in surgical group and in transfemoral TAVI group, and 73% in transapical TAVI group. When previous CABG is the lone surgical risk factor, indications for a TAVI procedure have to be cautious, specially if transfemoral approach is not possible.</p
    corecore