33 research outputs found

    Intensity-modulated radiotherapy of nasopharyngeal carcinoma: a comparative treatment planning study of photons and protons

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this treatment planning study was to investigate the potential advantages of intensity-modulated (IM) proton therapy (IMPT) compared with IM photon therapy (IMRT) in nasopharyngeal carcinoma (NPC).</p> <p>Methods</p> <p>Eight NPC patients were chosen. The dose prescriptions in cobalt Gray equivalent (Gy<sub>E</sub>) for gross tumor volumes of the primary tumor (GTV-T), planning target volumes of GTV-T and metastatic (PTV-TN) and elective (PTV-N) lymph node stations were 72.6 Gy<sub>E</sub>, 66 Gy<sub>E</sub>, and 52.8 Gy<sub>E</sub>, respectively. For each patient, nine coplanar fields IMRT with step-and-shoot technique and 3D spot-scanned three coplanar fields IMPT plans were prepared. Both modalities were planned in 33 fractions to be delivered with a simultaneous integrated boost technique. All plans were prepared and optimized by using the research version of the inverse treatment planning system KonRad (DKFZ, Heidelberg).</p> <p>Results</p> <p>Both treatment techniques were equal in terms of averaged mean dose to target volumes. IMPT plans significantly improved the tumor coverage and conformation (<it>P </it>< 0.05) and they reduced the averaged mean dose to several organs at risk (OARs) by a factor of 2–3. The low-to-medium dose volumes (0.33–13.2 Gy<sub>E</sub>) were more than doubled by IMRT plans.</p> <p>Conclusion</p> <p>In radiotherapy of NPC patients, three-field IMPT has greater potential than nine-field IMRT with respect to tumor coverage and reduction of the integral dose to OARs and non-specific normal tissues. The practicality of IMPT in NPC deserves further exploration when this technique becomes available on wider clinical scale.</p

    Current treatment options for recurrent nasopharyngeal cancer

    Get PDF
    Loco-regional control rate of nasopharyngeal carcinoma (NPC) has improved significantly in the past decade. However, local recurrence still represents a major cause of mortality and morbidity in advanced stages, and management of local failure remains a challenging issue in NPC. The best salvage treatment for local recurrent NPC remains to be determined. The options include brachytherapy, external radiotherapy, stereotactic radiosurgery, and nasopharyngectomy, either alone or in different combinations. In this article we will discuss the different options for salvage of locally recurrent NPC. Retreatment of locally recurrent NPC using radiotherapy, alone or in combination with other treatment modalities, as well as surgery, can result in long-term local control and survival in a substantial proportion of patients. For small-volume recurrent tumors (T1–T2) treated with external radiotherapy, brachytherapy or stereotactic radiosurgery, comparable results to those obtained with surgery have been reported. In contrast, treatment results of advanced-stage locally recurrent NPC are generally more satisfactory with surgery (with or without postoperative radiotherapy) than with reirradiation

    Assessment of the quality of measures of child oral health-related quality of life

    Get PDF
    Background Several measures of oral health-related quality of life have been developed for children. The most frequently used are the Child Perceptions Questionnaire (CPQ), the Child Oral Impacts on Daily Performances (C-OIDP) and the Child Oral Health Impact Profile (COHIP). The aim of this study was to assess the methodological quality of the development and testing of these three measures. Methods A systematic search strategy was used to identify eligible studies published up to December 2012, using both MEDLINE and Web of Science. Titles and abstracts were read independently by two investigators and full papers retrieved where the inclusion criteria were met. Data were extracted by two teams of two investigators using a piloted protocol. The data were used to describe the development of the measures and their use against existing criteria. The methodological quality and measurement properties of the measures were assessed using standards proposed by the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) group. Results The search strategy yielded 653 papers, of which 417 were duplicates. Following analysis of the abstracts, 119 papers met the inclusion criteria. The majority of papers reported cross-sectional studies (n = 117) with three of longitudinal design. Fifteen studies which had used the original version of the measures in their original language were included in the COSMIN analysis. The most frequently used measure was the CPQ. Reliability and construct validity appear to be adequate for all three measures. Children were not fully involved in item generation which may compromise their content validity. Internal consistency was measured using classic test theory with no evidence of modern psychometric techniques being used to test unidimensionality of the measures included in the COSMIN analysis. Conclusion The three measures evaluated appear to be able to discriminate between groups. CPQ has been most widely tested and several versions are available. COHIP employed a rigorous development strategy but has been tested in fewer populations. C-OIDP is shorter and has been used successfully in epidemiological studies. Further testing using modern psychometric techniques such as item response theory is recommended. Future developments should also focus on the development of measures which can evaluate longitudinal change

    International round-robin experiment on optical total scattering at 633 nm according to ISO/DIS 13696

    No full text
    The measurement of total scatter losses is a major prerequisite for the development, optimization and commercialization of high quality optical components. Especially in laser technology, optical scattering gained of importance in the source of the development of laser system with ever increasing output power and improved beam parameters. Besides its influence on the efficiency of laser systems and the beam steering arrangement, total scattering is an important safety aspect for application of these laser systems in materials processing, medicine and fundamental research. As a consequence of this global trend, working groups of TC 172/SC 9 initialized the development of an International Standard for the measurement of total scattering in optical components

    International round-robin experiment to test the International Organization for Standardization total-scattering draft standard

    No full text
    An international round-robin experiment has been conducted among laboratories in different countries to test the measurement and the data-analysis procedures in the International Organization for Standardization draft standard ISO/DIS 13696 for measuring total scattering from low-scatter laser optics. Ten laboratories measured total backscattering from high-reflectance mirrors, 50% beam splitters, and antireflection-coated windows. Results were sent to the Laser Zentrum Hannover, which acted as coordinator and analyzed all the backscattering data. The results showed that the procedure in the draft standard was useful for measuring and reporting backscattering for low-scatter optics. Problems encountered in the round-robin experiment included the accumulation of particles on the surfaces, particularly on the high-reflectance mirrors
    corecore