370 research outputs found

    Staphylococcus aureus bacteriuria as a prognosticator for outcome of Staphylococcus aureus bacteremia: a case-control study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>When <it>Staphylococcus aureus </it>is isolated in urine, it is thought to usually represent hematogenous spread. Because such spread might have special clinical significance, we evaluated predictors and outcomes of <it>S. aureus </it>bacteriuria among patients with <it>S. aureus </it>bacteremia.</p> <p>Methods</p> <p>A case-control study was performed at John H. Stroger Jr. Hospital of Cook County among adult inpatients during January 2002-December 2006. Cases and controls had positive and negative urine cultures, respectively, for <it>S. aureus</it>, within 72 hours of positive blood culture for <it>S. aureus</it>. Controls were sampled randomly in a 1:4 ratio. Univariate and multivariable logistic regression analyses were done.</p> <p>Results</p> <p>Overall, 59% of patients were African-American, 12% died, 56% of infections had community-onset infections, and 58% were infected with methicillin-susceptible <it>S. aureus </it>(MSSA). Among 61 cases and 247 controls, predictors of <it>S. aureus </it>bacteriuria on multivariate analysis were urological surgery (OR = 3.4, p = 0.06) and genitourinary infection (OR = 9.2, p = 0.002). Among patients who died, there were significantly more patients with bacteriuria than among patients who survived (39% vs. 17%; p = 0.002). In multiple Cox regression analysis, death risks in bacteremic patients were bacteriuria (hazard ratio 2.9, CI 1.4-5.9, p = 0.004), bladder catheter use (2.0, 1.0-4.0, p = 0.06), and Charlson score (1.1, 1.1-1.3, p = 0.02). Neither length of stay nor methicillin-resistant <it>Staphylococcus aureus </it>(MRSA) infection was a predictor of <it>S. aureus </it>bacteriuria or death.</p> <p>Conclusions</p> <p>Among patients with <it>S. aureus </it>bacteremia, those with <it>S. aureus </it>bacteriuria had 3-fold higher mortality than those without bacteriuria, even after adjustment for comorbidities. Bacteriuria may identify patients with more severe bacteremia, who are at risk of worse outcomes.</p

    Rationale and design of a randomized clinical trial comparing safety and efficacy of myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: The LANDMARK trial

    Get PDF
    BACKGROUND: The recent approval of transcatheter aortic valve replacement (TAVR) in patients with low operative risk has paved the way for the introduction of novel and potentially improved technologies. The safety and efficacy of these novel technologies should be investigated in randomized control trials against the contemporary TAVR devices. The objective of the LANDMARK trial is to compare the balloon-expandable Myval transcatheter heart valve (THV) series with contemporary THV (SAPIEN THV and Evolut THV series) series in patients with severe symptomatic native aortic stenosis. METHODS/DESIGN: The LANDMARK trial (ClinicalTrials.govNCT04275726, EudraCT number 2020-000,137-40) is a prospective, randomized, multinational, multicenter, open-label, and noninferiority trial of approximately 768 patients treated with TAVR via the transfemoral approach. Patients will be allocated in a 1:1 randomization to Myval THV series (n = 384) or to contemporary THV (n = 384) (either of SAPIEN THV or Evolut THV series). The primary combined safety and efficacy endpoint is a composite of all-cause mortality, all stroke (disabling and nondisabling), bleeding (life-threatening or disabling), acute kidney injury (stage 2 or 3), major vascular complications, prosthetic valve regurgitation (moderate or severe), and conduction system disturbances (requiring new permanent pacemaker implantation), according to the Valve Academic Research Consortium-2 criteria at 30-day follow-up. All patients will have follow-up to 10 years following TAVR. SUMMARY: The LANDMARK trial is the first randomized head-to-head trial comparing Myval THV series to commercially available THVs in patients indicated for TAVR. We review prior data on head-to-head comparisons of TAVR devices and describe the rationale and design of the LANDMARK trial

    Reference Group Choice and Antibiotic Resistance Outcomes

    Get PDF
    Two types of cohort studies examining patients infected with methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) were contrasted, using different reference groups. Cases were compared to uninfected patients and patients infected with the corresponding, susceptible organism. VRE and MRSA were associated with adverse outcomes. The effect was greater when uninfected control patients were used

    Polymer-based or polymer-free stents in patients at high bleeding risk

    Get PDF
    Background: polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. Methods: in an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. Results: a total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). Conclusions: among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.)

    Probiotics [LGG-BB12 or RC14-GR1] versus placebo as prophylaxis for urinary tract infection in persons with spinal cord injury [ProSCIUTTU]: a randomised controlled trial

    Full text link
    © 2019, The Author(s). Study design: Randomised double-blind factorial-design placebo-controlled trial. Objective: Urinary tract infections (UTIs) are common in people with spinal cord injury (SCI). UTIs are increasingly difficult to treat due to emergence of multi-resistant organisms. Probiotics are efficacious in preventing UTIs in post-menopausal women. We aimed to determine whether probiotic therapy with Lactobacillus reuteri RC-14+Lactobacillus GR-1 (RC14-GR1) and/or Lactobacillus rhamnosus GG+Bifidobacterium BB-12 (LGG-BB12) are effective in preventing UTI in people with SCI. Setting: Spinal units in New South Wales, Australia with their rural affiliations. Methods: We recruited 207 eligible participants with SCI and stable neurogenic bladder management. They were randomised to one of four arms: RC14-GR1+LGG-BB12, RC14-GR1+placebo, LGG-BB12+ placebo or double placebos for 6 months. Randomisation was stratified by bladder management type and inpatient or outpatient status. The primary outcome was time to occurrence of symptomatic UTI. Results: Analysis was based on intention to treat. Participants randomised to RC14-GR1 had a similar risk of UTI as those not on RC14-GR1 (HR 0.67; 95% CI: 0.39–1.18; P = 0.17) after allowing for pre-specified covariates. Participants randomised to LGG-BB12 also had a similar risk of UTI as those not on LGG-BB12 (HR 1.29; 95% CI: 0.74–2.25; P = 0.37). Multivariable post hoc survival analysis for RC14-GR1 only vs. the other three groups showed a potential protective effect (HR 0.46; 95% CI: 0.21–0.99; P = 0.03), but this result would need to be confirmed before clinical application. Conclusion: In this RCT, there was no effect of RC14-GR1 or LGG-BB12 in preventing UTI in people with SCI

    Quantitative aortography for assessment of aortic regurgitation in the era of percutaneous aortic valve replacement

    Get PDF
    Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries
    corecore