13 research outputs found

    Clinical laboratory reference values amongst children aged 4 weeks to 17 months in Kilifi, Kenya: A cross sectional observational study

    Get PDF
    Reference intervals for clinical laboratory parameters are important for assessing eligibility, toxicity grading and management of adverse events in clinical trials. Nonetheless, haematological and biochemical parameters used for clinical trials in sub-Saharan Africa are typically derived from industrialized countries, or from WHO references that are not region-specific. We set out to establish community reference values for haematological and biochemical parameters amongst children aged 4 weeks to 17 months in Kilifi, Kenya. We conducted a cross sectional study nested within phase II and III trials of RTS, S malaria vaccine candidate. We analysed 10 haematological and 2 biochemical parameters from 1,070 and 423 community children without illness prior to experimental vaccine administration. Statistical analysis followed Clinical and Laboratory Standards Institute EP28-A3c guidelines. 95% reference ranges and their respective 90% confidence intervals were determined using non-parametric methods. Findings were compared with published ranges from Tanzania, Europe and The United States. We determined the reference ranges within the following age partitions: 4 weeks to <6 months, 6 months to less than <12 months, and 12 months to 17 months for the haematological parameters; and 4 weeks to 17 months for the biochemical parameters. There were no gender differences for all haematological and biochemical parameters in all age groups. Hb, MCV and platelets 95% reference ranges in infants largely overlapped with those from United States or Europe, except for the lower limit for Hb, Hct and platelets (lower); and upper limit for platelets (higher) and haematocrit(lower). Community norms for common haematological and biochemical parameters differ from developed countries. This reaffirms the need in clinical trials for locally derived reference values to detect deviation from what is usual in typical children in low and middle income countries

    Serum screening with Down's syndrome markers to predict pre-eclampsia and small for gestational age: Systematic review and meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reliable antenatal identification of pre-eclampsia and small for gestational age is crucial to judicious allocation of monitoring resources and use of preventative treatment with the prospect of improving maternal/perinatal outcome. The purpose of this systematic review was to determine the accuracy of five serum analytes used in Down's serum screening for prediction of pre-eclampsia and/or small for gestational age.</p> <p>Methods</p> <p>The data sources included Medline, Embase, Cochrane library, Medion (inception to February 2007), hand searching of relevant journals, reference list checking of included articles, contact with experts. Two reviewers independently selected the articles in which the accuracy of an analyte used in Downs's serum screening before the 25<sup>th </sup>gestational week was associated with the occurrence of pre-eclampsia and/or small for gestational age without language restrictions. Two authors independently extracted data on study characteristics, quality and results.</p> <p>Results</p> <p>Five serum screening markers were evaluated. 44 studies, testing 169,637 pregnant women (4376 pre-eclampsia cases) and 86 studies, testing 382,005 women (20,339 fetal growth restriction cases) met the selection criteria. The results showed low predictive accuracy overall. For pre-eclampsia the best predictor was inhibin A>2.79MoM positive likelihood ratio 19.52 (8.33,45.79) and negative likelihood ratio 0.30 (0.13,0.68) (single study). For small for gestational age it was AFP>2.0MoM to predict birth weight < 10<sup>th </sup>centile with birth < 37 weeks positive likelihood ratio 27.96 (8.02,97.48) and negative likelihood ratio 0.78 (0.55,1.11) (single study). A potential clinical application using aspirin as a treatment is given as an example.</p> <p>There were methodological and reporting limitations in the included studies thus studies were heterogeneous giving pooled results with wide confidence intervals.</p> <p>Conclusion</p> <p>Down's serum screening analytes have low predictive accuracy for pre-eclampsia and small for gestational age. They may be a useful means of risk assessment or of use in prediction when combined with other tests.</p

    Real world hospital costs following stress echocardiography in the UK: a costing study from the EVAREST/BSE-NSTEP multi-centre study

    Get PDF
    Background: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and downstream hospital costs vary across NHS hospitals and identified key factors that affect costs to help inform future clinical planning and guidelines. Methods: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level. Results: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99) respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with significant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384–1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually. Conclusion: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to reflect actual value for money and support realistic planning

    The cost‐effectiveness of prophylaxis strategies for individuals with advanced HIV starting treatment in Africa

    Get PDF
    Introduction Many HIV‐positive individuals in Africa have advanced disease when initiating antiretroviral therapy (ART) so have high risks of opportunistic infections and death. The REALITY trial found that an enhanced‐prophylaxis package including fluconazole reduced mortality by 27% in individuals starting ART with CD4 <100 cells/mm3. We investigated the cost‐effectiveness of this enhanced‐prophylaxis package versus other strategies, including using cryptococcal antigen (CrAg) testing, in individuals with CD4 <200 cells/mm3 or <100 cells/mm3 at ART initiation and all individuals regardless of CD4 count. Methods The REALITY trial enrolled from June 2013 to April 2015. A decision‐analytic model was developed to estimate the cost‐effectiveness of six management strategies in individuals initiating ART in the REALITY trial countries. Strategies included standard‐prophylaxis, enhanced‐prophylaxis, standard‐prophylaxis with fluconazole; and three CrAg testing strategies, the first stratifying individuals to enhanced‐prophylaxis (CrAg‐positive) or standard‐prophylaxis (CrAg‐negative), the second to enhanced‐prophylaxis (CrAg‐positive) or enhanced‐prophylaxis without fluconazole (CrAg‐negative) and the third to standard‐prophylaxis with fluconazole (CrAg‐positive) or without fluconazole (CrAg‐negative). The model estimated costs, life‐years and quality‐adjusted life‐years (QALY) over 48 weeks using three competing mortality risks: cryptococcal meningitis; tuberculosis, serious bacterial infection or other known cause; and unknown cause. Results Enhanced‐prophylaxis was cost‐effective at cost‐effectiveness thresholds of US300andUS300 and US500 per QALY with an incremental cost‐effectiveness ratio (ICER) of US157perQALYintheCD4<200cells/mm3populationprovidingenhanced‐prophylaxiscomponentsaresourcedatlowestavailableprices.TheICERreducedinmoreseverelyimmunosuppressedindividuals(US157 per QALY in the CD4 <200 cells/mm3 population providing enhanced‐prophylaxis components are sourced at lowest available prices. The ICER reduced in more severely immunosuppressed individuals (US113 per QALY in the CD4 <100 cells/mm3 population) and increased in all individuals regardless of CD4 count (US722perQALY).Resultsweresensitivetopricesoftheenhanced‐prophylaxiscomponents.Enhanced‐prophylaxiswasmoreeffectiveandlesscostlythanallCrAgtestingstrategiesasenhanced‐prophylaxisstillconveyedhealthgainsinCrAg‐negativepatientsandsavingsfromtargetingprophylaxisbasedonCrAgstatusdidnotcompensateforcostsofCrAgtesting.CrAgtestingstrategiesdidnotbecomecost‐effectiveunlessthepriceofCrAgtestingfellbelowUS722 per QALY). Results were sensitive to prices of the enhanced‐prophylaxis components. Enhanced‐prophylaxis was more effective and less costly than all CrAg testing strategies as enhanced‐prophylaxis still conveyed health gains in CrAg‐negative patients and savings from targeting prophylaxis based on CrAg status did not compensate for costs of CrAg testing. CrAg testing strategies did not become cost‐effective unless the price of CrAg testing fell below US2.30. Conclusions The REALITY enhanced‐prophylaxis package in individuals with advanced HIV starting ART reduces morbidity and mortality, is practical to administer and is cost‐effective. Efforts should continue to ensure that components are accessed at lowest available prices

    Late Presentation With HIV in Africa: Phenotypes, Risk, and Risk Stratification in the REALITY Trial.

    Get PDF
    This article has been accepted for publication in Clinical Infectious Diseases Published by Oxford University PressBackground: Severely immunocompromised human immunodeficiency virus (HIV)-infected individuals have high mortality shortly after starting antiretroviral therapy (ART). We investigated predictors of early mortality and "late presenter" phenotypes. Methods: The Reduction of EArly MortaLITY (REALITY) trial enrolled ART-naive adults and children ≄5 years of age with CD4 counts .1). Results: Among 1711 included participants, 203 (12%) died. Mortality was independently higher with older age; lower CD4 count, albumin, hemoglobin, and grip strength; presence of World Health Organization stage 3/4 weight loss, fever, or vomiting; and problems with mobility or self-care at baseline (all P < .04). Receiving enhanced antimicrobial prophylaxis independently reduced mortality (P = .02). Of five late-presenter phenotypes, Group 1 (n = 355) had highest mortality (25%; median CD4 count, 28 cells/”L), with high symptom burden, weight loss, poor mobility, and low albumin and hemoglobin. Group 2 (n = 394; 11% mortality; 43 cells/”L) also had weight loss, with high white cell, platelet, and neutrophil counts suggesting underlying inflammation/infection. Group 3 (n = 218; 10% mortality) had low CD4 counts (27 cells/”L), but low symptom burden and maintained fat mass. The remaining groups had 4%-6% mortality. Conclusions: Clinical and laboratory features identified groups with highest mortality following ART initiation. A screening tool could identify patients with low CD4 counts for prioritizing same-day ART initiation, enhanced prophylaxis, and intensive follow-up. Clinical Trials Registration: ISRCTN43622374.REALITY was funded by the Joint Global Health Trials Scheme (JGHTS) of the UK Department for International Development, the Wellcome Trust, and Medical Research Council (MRC) (grant number G1100693). Additional funding support was provided by the PENTA Foundation and core support to the MRC Clinical Trials Unit at University College London (grant numbers MC_UU_12023/23 and MC_UU_12023/26). Cipla Ltd, Gilead Sciences, ViiV Healthcare/GlaxoSmithKline, and Merck Sharp & Dohme donated drugs for REALITY, and ready-to-use supplementary food was purchased from Valid International. A. J. P. is funded by the Wellcome Trust (grant number 108065/Z/15/Z). J. A. B. is funded by the JGHTS (grant number MR/M007367/1). The Malawi-Liverpool–Wellcome Trust Clinical Research Programme, University of Malawi College of Medicine (grant number 101113/Z/13/Z) and the Kenya Medical Research Institute (KEMRI)/Wellcome Trust Research Programme, Kilifi (grant number 203077/Z/16/Z) are supported by strategic awards from the Wellcome Trust, United Kingdom. Permission to publish was granted by the Director of KEMRI. This supplement was supported by funds from the Bill & Melinda Gates Foundation

    Clinical laboratory reference values amongst children aged 4 weeks to 17 months in Kilifi, Kenya: A cross sectional observational study

    No full text
    Reference intervals for clinical laboratory parameters are important for assessing eligibility, toxicity grading and management of adverse events in clinical trials. Nonetheless, haematological and biochemical parameters used for clinical trials in sub-Saharan Africa are typically derived from industrialized countries, or from WHO references that are not region-specific. We set out to establish community reference values for haematological and biochemical parameters amongst children aged 4 weeks to 17 months in Kilifi, Kenya. We conducted a cross sectional study nested within phase II and III trials of RTS, S malaria vaccine candidate. We analysed 10 haematological and 2 biochemical parameters from 1,070 and 423 community children without illness prior to experimental vaccine administration. Statistical analysis followed Clinical and Laboratory Standards Institute EP28-A3c guidelines. 95% reference ranges and their respective 90% confidence intervals were determined using non-parametric methods. Findings were compared with published ranges from Tanzania, Europe and The United States. We determined the reference ranges within the following age partitions: 4 weeks to &lt;6 months, 6 months to less than &lt;12 months, and 12 months to 17 months for the haematological parameters; and 4 weeks to 17 months for the biochemical parameters. There were no gender differences for all haematological and biochemical parameters in all age groups. Hb, MCV and platelets 95% reference ranges in infants largely overlapped with those from United States or Europe, except for the lower limit for Hb, Hct and platelets (lower); and upper limit for platelets (higher) and haematocrit(lower). Community norms for common haematological and biochemical parameters differ from developed countries. This reaffirms the need in clinical trials for locally derived reference values to detect deviation from what is usual in typical children in low and middle income countries
    corecore