205 research outputs found
Femtosecond resolution timing jitter correction on a TW scale Ti:sapphire laser system for FEL pump-probe experiments
Intense ultrashort pulse lasers are used for fs resolution pumpprobe
experiments more and more at large scale facilities, such as free electron
lasers (FEL). Measurement of the arrival time of the laser pulses and
stabilization to the machine or other sub-systems on the target, is crucial for
high time-resolution measurements. In this work we report on a single shot,
spectrally resolved, non-collinear cross-correlator with sub-fs resolution.
With a feedback applied we keep the output of the TW class Ti:sapphire
amplifier chain in time with the seed oscillator to ~3 fs RMS level for several
hours. This is well below the typical pulse duration used at FELs and supports
fs resolution pump-probe experiments. Short term jitter and long term timing
drift measurements are presented. Applicability to other wavelengths and
integration into the timing infrastructure of the FEL are also covered to show
the full potential of the device
Multiple Synchronous Squamous Cell Cancers of the Skin and Esophagus: Differential Management of Primary Versus Secondary Tumor
Multiple primary tumors are uncommon in patients with squamous cell esophageal cancer. Conventional imaging methods have limitations in detecting those tumors. Although 18-F-fluoro-deoxyglucose-positron emission tomography scanner increases the detection of multiple synchronous tumors in patients with other malignancies, its contribution in patients with squamous cell esophageal cancer has not been assessed as it is not systematically performed. The detection of synchronous skin squamous cell tumors in patients with squamous cell esophageal cancer presents a challenge for making diagnostic and therapeutic decisions. A metastatic tumor leads to palliative management, whereas the diagnosis of a primary skin tumor requires curative treatment of both squamous cell tumors. Pathological evaluation appears crucial in the decision
Hyperspectral Imaging in Major Hepatectomies: Preliminary Results from the Ex-Machyna Trial.
Ischemia-reperfusion injury during major hepatic resections is associated with high rates of post-operative complications and liver failure. Real-time intra-operative detection of liver dysfunction could provide great insight into clinical outcomes. In the present study, we demonstrate the intra-operative application of a novel optical technology, hyperspectral imaging (HSI), to predict short-term post-operative outcomes after major hepatectomy. We considered fifteen consecutive patients undergoing major hepatic resection for malignant liver lesions from January 2020 to June 2021. HSI measures included tissue water index (TWI), organ hemoglobin index (OHI), tissue oxygenation (StO2%), and near infrared (NIR). Pre-operative, intra-operative, and post-operative serum and clinical outcomes were collected. NIR values were higher in unhealthy liver tissue (p = 0.003). StO2% negatively correlated with post-operative serum ALT values (r = -0.602), while ΔStO2% positively correlated with ALP (r = 0.594). TWI significantly correlated with post-operative reintervention and OHI with post-operative sepsis and liver failure. In conclusion, the HSI imaging system is accurate and precise in translating from pre-clinical to human studies in this first clinical trial. HSI indices are related to serum and outcome metrics. Further experimental and clinical studies are necessary to determine clinical value of this technology
Search for R-Parity Violating Decays of Scalar Fermions at LEP
A search for pair-produced scalar fermions under the assumption that R-parity
is not conserved has been performed using data collected with the OPAL detector
at LEP. The data samples analysed correspond to an integrated luminosity of
about 610 pb-1 collected at centre-of-mass energies of sqrt(s) 189-209 GeV. An
important consequence of R-parity violation is that the lightest supersymmetric
particle is expected to be unstable. Searches of R-parity violating decays of
charged sleptons, sneutrinos and squarks have been performed under the
assumptions that the lightest supersymmetric particle decays promptly and that
only one of the R-parity violating couplings is dominant for each of the decay
modes considered. Such processes would yield final states consisting of
leptons, jets, or both with or without missing energy. No significant
single-like excess of events has been observed with respect to the Standard
Model expectations. Limits on the production cross- section of scalar fermions
in R-parity violating scenarios are obtained. Constraints on the supersymmetric
particle masses are also presented in an R-parity violating framework analogous
to the Constrained Minimal Supersymmetric Standard Model.Comment: 51 pages, 24 figures, Submitted to Eur. Phys. J.
Tests of model of color reconnection and a search for glueballs using gluon jets with a rapidity gap
Gluon jets with a mean energy of 22 GeV and purity of 95% are selected from
hadronic Z0 decay events produced in e+e- annihilations. A subsample of these
jets is identified which exhibits a large gap in the rapidity distribution of
particles within the jet. After imposing the requirement of a rapidity gap, the
gluon jet purity is 86%. These jets are observed to demonstrate a high degree
of sensitivity to the presence of color reconnection, i.e. higher order QCD
processes affecting the underlying color structure. We use our data to test
three QCD models which include a simulation of color reconnection: one in the
Ariadne Monte Carlo, one in the Herwig Monte Carlo, and the other by Rathsman
in the Pythia Monte Carlo. We find the Rathsman and Ariadne color reconnection
models can describe our gluon jet measurements only if very large values are
used for the cutoff parameters which serve to terminate the parton showers, and
that the description of inclusive Z0 data is significantly degraded in this
case. We conclude that color reconnection as implemented by these two models is
disfavored. The signal from the Herwig color reconnection model is less clear
and we do not obtain a definite conclusion concerning this model. In a separate
study, we follow recent theoretical suggestions and search for glueball-like
objects in the leading part of the gluon jets. No clear evidence is observed
for these objects.Comment: 42 pages, 18 figure
Measurement of the Hadronic Photon Structure Function F_2^gamma at LEP2
The hadronic structure function of the photon F_2^gamma is measured as a
function of Bjorken x and of the factorisation scale Q^2 using data taken by
the OPAL detector at LEP. Previous OPAL measurements of the x dependence of
F_2^gamma are extended to an average Q^2 of 767 GeV^2. The Q^2 evolution of
F_2^gamma is studied for average Q^2 between 11.9 and 1051 GeV^2. As predicted
by QCD, the data show positive scaling violations in F_2^gamma. Several
parameterisations of F_2^gamma are in agreement with the measurements whereas
the quark-parton model prediction fails to describe the data.Comment: 4 pages, 2 figures, to appear in the proceedings of Photon 2001,
Ascona, Switzerlan
Search for the Standard Model Higgs Boson with the OPAL Detector at LEP
This paper summarises the search for the Standard Model Higgs boson in e+e-
collisions at centre-of-mass energies up to 209 GeV performed by the OPAL
Collaboration at LEP. The consistency of the data with the background
hypothesis and various Higgs boson mass hypotheses is examined. No indication
of a signal is found in the data and a lower bound of 112.7GeV/C^2 is obtained
on the mass of the Standard Model Higgs boson at the 95% CL.Comment: 51 pages, 21 figure
Search for Yukawa Production of a Light Neutral Higgs Boson at LEP
Within a Two-Higgs-Doublet Model (2HDM) a search for a light Higgs boson in
the mass range of 4-12 GeV has been performed in the Yukawa process e+e- -> b
bbar A/h -> b bbar tau+tau-, using the data collected by the OPAL detector at
LEP between 1992 and 1995 in e+e- collisions at about 91 GeV centre-of-mass
energy. A likelihood selection is applied to separate background and signal.
The number of observed events is in good agreement with the expected
background. Within a CP-conserving 2HDM type II model the cross-section for
Yukawa production depends on xiAd = |tan beta| and xihd = |sin alpha/cos beta|
for the production of the CP-odd A and the CP-even h, respectively, where tan
beta is the ratio of the vacuum expectation values of the Higgs doublets and
alpha is the mixing angle between the neutral CP-even Higgs bosons. From our
data 95% C.L. upper limits are derived for xiAd within the range of 8.5 to 13.6
and for xihd between 8.2 to 13.7, depending on the mass of the Higgs boson,
assuming a branching fraction into tau+tau- of 100%. An interpretation of the
limits within a 2HDM type II model with Standard Model particle content is
given. These results impose constraints on several models that have been
proposed to explain the recent BNL measurement of the muon anomalous magnetic
moment.Comment: 24 pages, 9 figures, Submitted to Euro. Phys. J.
A study of charm production in beauty decays with the OPAL detector at LEP
Using an inclusive method, BR(b -> D\bar{D}X) has been measured in hadronic
Z^0 decays with the OPAL detector at LEP. The impact parameter significance of
tracks opposite tagged b-jets is used to differentiate b -> D\bar{D}X decays
from other decays. Using this result, the average number of charm and
anti-charm quarks produced per beauty quark decay, n_c, is determined.Comment: 20 pages, 4 figure
Measurement of the Hadronic Cross-Section for the Scattering of Two Virtual Photons at LEP
The interaction of virtual photons is investigated using the reaction e+e- ->
e+e- hadrons based on data taken by the OPAL experiment at e+e- centre-of-mass
energies sqrt(s_ee)=189-209 GeV, for W>5 GeV and at an average Q^2 of 17.9
GeV^2. The measured cross-sections are compared to predictions of the Quark
Parton Model (QPM), to the Leading Order QCD Monte Carlo model PHOJET to the
NLO prediction for the reaction e+e- -> e+e-qqbar, and to BFKL calculations.
PHOJET, NLO e+e- -> e+e-qqbar, and QPM describe the data reasonably well,
whereas the cross-section predicted by a Leading Order BFKL calculation is too
large.Comment: 30 pages, 10 figures, Submitted to Eur.Phys.J.
- …