596 research outputs found
Paediatric olecranon fractures: a systematic review.
The optimal management and long-term outcomes of olecranon fractures in the paediatric population is not well understood. This systematic review aims to analyse the literature on the management of paediatric olecranon fractures and the long-term implications.A systematic review of several databases was conducted according to PRISMA guidelines. English-language studies evaluating the management of isolated paediatric olecranon fractures were included. Data extracted included demographics, classifications, conservative and operative treatment methods and outcomes.Fifteen articles fitting the inclusion criteria were included. There were 11 case series and four retrospective comparative series. The reported studies included 299 fractures in 280 patients.The mechanism of injury was predominantly low energy. Fractures displaced 4 mm were commonly treated operatively with generally good results, with tension band wire and suture fixation being the most common treatment modalities. Weight > 50 kg was associated with failure of suture fixation.In those studies that reported olecranon fractures with associated elbow injuries (e.g. radial head fractures) outcomes were poorer. Forty-six fractures were in patients with osteogenesis imperfecta, who sustained a higher rate of re-fracture after removal of metalwork and contralateral olecranon fracture.Despite a relatively low evidence base pool of studies, the aggregate data support the non-operative treatment of isolated undisplaced olecranon fractures with good results, and support the operative treatment of fractures displaced ≥ 4 mm. Cite this article: EFORT Open Rev 2020;5:280-288. DOI: 10.1302/2058-5241.5.190082
Die Biegestabprothese: ein experimenteller Ansatz zur metaphysären Hüftendoprothetik
The aim of our study was to develop a femoral component for total hip arthroplasty that would exclusively anchor in the metaphysis of the femoral neck. To forego trochanteric fixation, the load needs to be transferred to the metaphysis at as many points as possible. A computer simulation model suggested that an implant with a central cylinder and 16 rods aligned along a thread would be the preferable solution. To evaluate primary implantation stability, 14 fresh frozen cadaver femora were used. A special instrument set was developed to allow for centered implantation of the prosthesis without the need to dissect the greater trochanter. For our tests, we used two prototype implants: one made from titanium and the other from a CoCrMo alloy. For the measurement of micromotions at the medial proximal femur, sinusoid dynamic loading with a force between 300 N and 1700 N and a frequency of 1 Hz was employed. In a neutral position of 16 degrees adduction and 9 degrees ante-torsion, the average micronnotions measured were 119 mu m. Despite these convincing in vitro results with regards to primary stability, circular cut-out of the implant, followed by aseptic osteonecrosis, loosening might still occur in a clinical situation. Animal experiments are therefore required to further evaluate this new implant design
Posterior dislocation of the elbow associated with fracture of the radial head and olecranon, and with medial collateral ligament disruption: A case report
Use of antibiotic spacers for knee endoprosthesis infections treatment
OBJCTIVE: The aim of this study is to evaluate the use of cement spacers impregnated with antibiotics for the treatment of infections in the nonconventional endoprostheses of the knee. METHODOLOGY: We have treated seven patients since 2004 (of which six were submitted to surgery in our service and one patient had been submitted to a primary tumor surgery in another removal service) with deep infection in knee tumor prosthesis. All patients were submitted to endoprosthesis removal and reconstructed with antibiotic cement spacer. All patients were monitored both clinically and by lab tests as for monitoring the evolution, being considered able for reviews after 6 (six) months without infections signs. RESULTS: We have noted a small predominance of infectious processes on the prosthesis inserted on proximal tibia as compared with distal femur (57.1% x 42.9%). The mean follow-up time of patients was 68.2 months. During the follow up, one patient died as a result of the root disease. Six patients out of seven were regarded as cured and one persisted with infection signs and symptoms. CONCLUSION: The results obtained up to date have motivated us to continue using this method of treatment.OBJETIVO: O objetivo do estudo é avaliar a utilização dos espaçadores de cimento acrílico com antibiótico no tratamento das infecções em endopróteses não convencionais de joelho. MÉTODO: Desde de 2004 foram tratados sete pacientes (seis pacientes operados no nosso serviço e um paciente que havia sido submetido a cirurgia primária do tumor em outro serviço) com infecção peri-endoprótese não convencional de joelho. Todos pacientes foram submetidos a retirada da endoprótese e reconstrução com espaçador com cimento acrílico com antibiótico. Todos os pacientes foram monitorados clínica e laboratorialmente quanto ao controle da evolução, sendo considerados aptos para a revisão e recolocação de endoprótese após 06 (seis) meses sem sinais infecciosos RESULTADOS: Notamos um discreto predomínio do do processo infeccioso nas próteses realizadas na tíbia proximal em comparação com o fêmur distal (57,1% x 42,9%). O seguimento médio dos pacientes foi 68,2 meses. Durante o seguimento, um paciente faleceu devido a doença de base. Dos sete pacientes, 6 foram considerados curados e um persistiu com sinais e sintomas de infecção. CONCLUSÃO: Os resultados obtidos até o momento tem motivado a continuidade deste método de tratamento.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Ortopedia e TraumatologiaUNIFESP, EPM, Depto. de Ortopedia e TraumatologiaSciEL
Can osseous landmarks in the distal medial humerus be used to identify the attachment sites of ligaments and tendons: paleopathologic–anatomic imaging study in cadavers
Objective: To describe osseous landmarks that allow identification of the attachments of the ligaments and tendons in the distal medial aspect of the humerus. Materials and methods: Reliable osseous landmarks in the distal medial aspect of the humerus were identified in 34 well-preserved specimens from a paleopathologic collection. These osseous landmarks were then sought in magnetic resonance (MR) images of ten cadaveric elbow specimens so that the ease of their visualization and optimal imaging plane could be assessed. To assign these osseous landmarks to specific attachments of the tendons and ligaments in the distal medial humerus, we cut the specimens in slices and photographed and examined them. Subsequently, the prevalence of these osseous landmarks as well as the attachment sites of the tendons and ligaments in this location was determined. Results: We determined ten reliable osseous landmarks in the distal medial aspect of the humerus, their prevalence and ease of identification, and their relationship to the attachments of the tendons and ligaments at the medial distal humerus. Conclusion: It is possible to use osseous landmarks at the distal medial humerus to facilitate identification of the different attachments of tendons and ligaments when MR images of the elbow are assesse
Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture
<p>Abstract</p> <p>Background</p> <p>Hip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral neck fracture patients operated with a posterior approach with cemented conventional or dual articulation acetabular components.</p> <p>Methods</p> <p>We compared the dislocation rate in 56 consecutive patients operated with conventional (single mobility) cemented acetabular components to that in 42 consecutive patients operated with dual articulation acetabular components. All the patients were operated via posterior approach and were followed up to one year postoperatively.</p> <p>Results</p> <p>There were 8 dislocations in the 56 patients having conventional components as compared to no dislocations in those 42 having dual articulation components (p = 0.01). The groups were similar with respect to age and gender distribution.</p> <p>Conclusions</p> <p>We conclude that the use of a cemented dual articulation acetabular component significantly reduces the dislocation rates in femoral neck fracture patients operated via posterior approach.</p
Successful Closed Reduction of a Dislocated Constrained Total Hip Arthroplasty: A Case Report and Literature Review
Many surgeons use acetabular components with constrained polyethylene liners to improve stability after total hip arthroplasty in patients with a history of hip dislocation. Surgical treatment is generally thought to be the only available option for the dislocated constrained liner. The success rate and clinical results of closed reduction for such patients is unclear. This report presents a case of a successful closed reduction of a dislocated constrained liner. Few papers have so far addressed closed reduction of a dislocated constrained liner. Furthermore, previous studies reported a variety of components. Publication of additional successful and unsuccessful case reports is therefore needed to help establish the optimal treatment protocol for a dislocated constrained liner
The effect of posterior capsule repair upon post-operative hip dislocation following primary total hip arthroplasty
<p>Abstract</p> <p>Background</p> <p>Herein, we evaluated, retrospectively, the effect of posterior capsular repair upon postoperative hip dislocation subsequent to total hip arthroplasty (THA) incorporating a posterolateral approach.</p> <p>Methods</p> <p>A total of 181 patients undergoing 204 primary non-complicated THA surgical procedures in the period from January 2000 to October 2005 inclusively were included in this study. The patients were separated into two groups by whether the posterior capsular repair had been incorporated in the surgical procedure. For the surgeon did not commence repairing the posterior capsule until July, 2003, all members in the group that did not undergo posterior capsular repair (142 hips from 131 patients) were collected since January, 2000 to July, 2003, while the members in the group that underwent posterior capsular repair (62 hips from 52 patients) were followed since July, 2003, to October, 2005. With a minimum follow-up period of 12 months, we evaluated the early post-operative dislocation rate.</p> <p>Results</p> <p>The early postoperative hip-dislocation rate for the group who did not undergo posterior capsular repair appeared to be substantially greater (6.38% versus 0%) than the corresponding figure for the group the members of which underwent posterior capsular repair. In addition, patient demographics and the orientation of acetabular components for the replaced hip joints, as presented in postoperative radiographs, did not differ between the two groups.</p> <p>Conclusion</p> <p>Thus, surgeons should include posterior capsular repair as an important step in the surgical procedures of posterolateral approach for all THA in order to reduce the likelihood of early hip dislocation subsequent to THA.</p
- …
