538 research outputs found

    Paediatric olecranon fractures: a systematic review.

    Get PDF
    The optimal management and long-term outcomes of olecranon fractures in the paediatric population is not well understood. This systematic review aims to analyse the literature on the management of paediatric olecranon fractures and the long-term implications.A systematic review of several databases was conducted according to PRISMA guidelines. English-language studies evaluating the management of isolated paediatric olecranon fractures were included. Data extracted included demographics, classifications, conservative and operative treatment methods and outcomes.Fifteen articles fitting the inclusion criteria were included. There were 11 case series and four retrospective comparative series. The reported studies included 299 fractures in 280 patients.The mechanism of injury was predominantly low energy. Fractures displaced 4 mm were commonly treated operatively with generally good results, with tension band wire and suture fixation being the most common treatment modalities. Weight > 50 kg was associated with failure of suture fixation.In those studies that reported olecranon fractures with associated elbow injuries (e.g. radial head fractures) outcomes were poorer. Forty-six fractures were in patients with osteogenesis imperfecta, who sustained a higher rate of re-fracture after removal of metalwork and contralateral olecranon fracture.Despite a relatively low evidence base pool of studies, the aggregate data support the non-operative treatment of isolated undisplaced olecranon fractures with good results, and support the operative treatment of fractures displaced ≥ 4 mm. Cite this article: EFORT Open Rev 2020;5:280-288. DOI: 10.1302/2058-5241.5.190082

    Can osseous landmarks in the distal medial humerus be used to identify the attachment sites of ligaments and tendons: paleopathologic–anatomic imaging study in cadavers

    Get PDF
    Objective: To describe osseous landmarks that allow identification of the attachments of the ligaments and tendons in the distal medial aspect of the humerus. Materials and methods: Reliable osseous landmarks in the distal medial aspect of the humerus were identified in 34 well-preserved specimens from a paleopathologic collection. These osseous landmarks were then sought in magnetic resonance (MR) images of ten cadaveric elbow specimens so that the ease of their visualization and optimal imaging plane could be assessed. To assign these osseous landmarks to specific attachments of the tendons and ligaments in the distal medial humerus, we cut the specimens in slices and photographed and examined them. Subsequently, the prevalence of these osseous landmarks as well as the attachment sites of the tendons and ligaments in this location was determined. Results: We determined ten reliable osseous landmarks in the distal medial aspect of the humerus, their prevalence and ease of identification, and their relationship to the attachments of the tendons and ligaments at the medial distal humerus. Conclusion: It is possible to use osseous landmarks at the distal medial humerus to facilitate identification of the different attachments of tendons and ligaments when MR images of the elbow are assesse

    Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral neck fracture patients operated with a posterior approach with cemented conventional or dual articulation acetabular components.</p> <p>Methods</p> <p>We compared the dislocation rate in 56 consecutive patients operated with conventional (single mobility) cemented acetabular components to that in 42 consecutive patients operated with dual articulation acetabular components. All the patients were operated via posterior approach and were followed up to one year postoperatively.</p> <p>Results</p> <p>There were 8 dislocations in the 56 patients having conventional components as compared to no dislocations in those 42 having dual articulation components (p = 0.01). The groups were similar with respect to age and gender distribution.</p> <p>Conclusions</p> <p>We conclude that the use of a cemented dual articulation acetabular component significantly reduces the dislocation rates in femoral neck fracture patients operated via posterior approach.</p

    Die Biegestabprothese: ein experimenteller Ansatz zur metaphysären Hüftendoprothetik

    Get PDF
    The aim of our study was to develop a femoral component for total hip arthroplasty that would exclusively anchor in the metaphysis of the femoral neck. To forego trochanteric fixation, the load needs to be transferred to the metaphysis at as many points as possible. A computer simulation model suggested that an implant with a central cylinder and 16 rods aligned along a thread would be the preferable solution. To evaluate primary implantation stability, 14 fresh frozen cadaver femora were used. A special instrument set was developed to allow for centered implantation of the prosthesis without the need to dissect the greater trochanter. For our tests, we used two prototype implants: one made from titanium and the other from a CoCrMo alloy. For the measurement of micromotions at the medial proximal femur, sinusoid dynamic loading with a force between 300 N and 1700 N and a frequency of 1 Hz was employed. In a neutral position of 16 degrees adduction and 9 degrees ante-torsion, the average micronnotions measured were 119 mu m. Despite these convincing in vitro results with regards to primary stability, circular cut-out of the implant, followed by aseptic osteonecrosis, loosening might still occur in a clinical situation. Animal experiments are therefore required to further evaluate this new implant design

    Successful Closed Reduction of a Dislocated Constrained Total Hip Arthroplasty: A Case Report and Literature Review

    Get PDF
    Many surgeons use acetabular components with constrained polyethylene liners to improve stability after total hip arthroplasty in patients with a history of hip dislocation. Surgical treatment is generally thought to be the only available option for the dislocated constrained liner. The success rate and clinical results of closed reduction for such patients is unclear. This report presents a case of a successful closed reduction of a dislocated constrained liner. Few papers have so far addressed closed reduction of a dislocated constrained liner. Furthermore, previous studies reported a variety of components. Publication of additional successful and unsuccessful case reports is therefore needed to help establish the optimal treatment protocol for a dislocated constrained liner

    Total Elbow Arthroplasty

    Get PDF
    Total elbow arthroplasty has continued to evolve over time. Elbow implants may be linked or unlinked. Unlinked implants are attractive for patients with relatively well preserved bone stock and ligaments, but many favor linked implants, since they prevent instability and allow replacement for a wider spectrum of indications. Inflammatory arthropathies such as rheumatoid arthritis represent the classic indication for elbow arthroplasty. Indications have been expanded to include posttraumatic osteoarthritis, acute distal humerus fractures, distal humerus nonunions and reconstruction after tumor resection. Elbow arthroplasty is very successful in terms of pain relief, motion and function. However, its complication rate remains higher than arthroplasty of other joints. The overall success rate is best for patients with inflammatory arthritis and elderly patients with acute distal humerus fractures, worse for patients with posttraumatic osteoarthritis. The most common complications of elbow arthroplasty include infection, loosening, wear, triceps weakness and ulnar neuropathy. When revision surgery becomes necessary, bone augmentation techniques provide a reasonable outcome

    The effect of posterior capsule repair upon post-operative hip dislocation following primary total hip arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Herein, we evaluated, retrospectively, the effect of posterior capsular repair upon postoperative hip dislocation subsequent to total hip arthroplasty (THA) incorporating a posterolateral approach.</p> <p>Methods</p> <p>A total of 181 patients undergoing 204 primary non-complicated THA surgical procedures in the period from January 2000 to October 2005 inclusively were included in this study. The patients were separated into two groups by whether the posterior capsular repair had been incorporated in the surgical procedure. For the surgeon did not commence repairing the posterior capsule until July, 2003, all members in the group that did not undergo posterior capsular repair (142 hips from 131 patients) were collected since January, 2000 to July, 2003, while the members in the group that underwent posterior capsular repair (62 hips from 52 patients) were followed since July, 2003, to October, 2005. With a minimum follow-up period of 12 months, we evaluated the early post-operative dislocation rate.</p> <p>Results</p> <p>The early postoperative hip-dislocation rate for the group who did not undergo posterior capsular repair appeared to be substantially greater (6.38% versus 0%) than the corresponding figure for the group the members of which underwent posterior capsular repair. In addition, patient demographics and the orientation of acetabular components for the replaced hip joints, as presented in postoperative radiographs, did not differ between the two groups.</p> <p>Conclusion</p> <p>Thus, surgeons should include posterior capsular repair as an important step in the surgical procedures of posterolateral approach for all THA in order to reduce the likelihood of early hip dislocation subsequent to THA.</p
    • …
    corecore