32 research outputs found

    Off-pump coronary artery bypass in poland syndrome with dextrocardia: case report

    Get PDF
    Poland Syndrome is a congenital disorder characterised by hypoplasia of the pectoral muscles along with upper extremity deformities. We encountered a patient with Poland syndrome associated with dextrocardia and also failed pectus excavatum repairs who presented to us with symptomatic ischaemic heart disease requiring intervention. He underwent successful off-pump coronary artery bypass surgery (OPCABG). As far as we are aware, this is the first case report of OPCABG in a case of Poland syndrome with dextrocardia. We describe here the management of this complex patient and wish to emphasise that the off-pump option is feasible in dextrocardia with some technical modifications

    Stable Field Emission from Layered MoS2 Nanosheets in High Vacuum and Observation of 1/f Noise

    Get PDF
    Field emission and current noise of hydrothermally synthesized MoS2 nanosheets are investigated in ultra-high-vacuum and industrially suited high-vacuum conditions. The study reveals that the emission turn-on field is pressure dependent. Moreover, the MoS2 nano‐sheets exhibit more stable field-electron emission in high- vacuum than in ultra-high-vacuum conditions. The investigations on field-emission current fluctuations show features of 1/f-type noise in ultra-high-vacuum and high-vacuum conditions, attributed to adsorption and desorption processes. The post-field-emission results indicate the MoS2 nanosheets are a robust field emitter in high-vacuum conditions

    Hospital admission with non-alcoholic fatty liver disease is associated with increased all-cause mortality independent of cardiovascular risk factors

    Get PDF
    Non-alcoholic fatty liver disease (NAFLD) is common and strongly associated with the metabolic syndrome. Though NAFLD may progress to end-stage liver disease, the top cause of mortality in NAFLD is cardiovascular disease (CVD). Most of the data on liver-related mortality in NAFLD derives from specialist liver centres. It is not clear if the higher reported mortality rates in individuals with non-cirrhotic NAFLD are entirely accounted for by complications of atherosclerosis and diabetes. Therefore, we aimed to describe the CVD burden and mortality in NAFLD when adjusting for metabolic risk factors using a ‘real world’ cohort. We performed a retrospective study of patients followed-up after an admission to non-specialist hospitals with a NAFLD-spectrum diagnosis. Non-cirrhotic NAFLD and NAFLD-cirrhosis patients were defined by ICD-10 codes. Cases were age-/sex-matched with non-NAFLD hospitalised patients. All-cause mortality over 14-years follow-up after discharge was compared between groups using Cox proportional hazard models adjusted for demographics, CVD, and metabolic syndrome components. We identified 1,802 patients with NAFLD-diagnoses: 1,091 with non-cirrhotic NAFLD and 711 with NAFLD-cirrhosis, matched to 24,737 controls. There was an increasing burden of CVD with progression of NAFLD: for congestive heart failure 3.5% control, 4.2% non-cirrhotic NAFLD, 6.6% NAFLD-cirrhosis; and for atrial fibrillation 4.7% control, 5.9% non-cirrhotic NAFLD, 12.1% NAFLD-cirrhosis. Over 14-years follow-up, crude mortality rates were 14.7% control, 13.7% non-cirrhotic NAFLD, and 40.5% NAFLD-cirrhosis. However, after adjusting for demographics, non-cirrhotic NAFLD (HR 1.3 (95% CI 1.1–1.5)) as well as NAFLD-cirrhosis (HR 3.7 (95% CI 3.0–4.5)) patients had higher mortality compared to controls. These differences remained after adjusting for CVD and metabolic syndrome components: non-cirrhotic NAFLD (HR 1.2 (95% CI 1.0–1.4)) and NAFLD-cirrhosis (HR 3.4 (95% CI 2.8–4.2)). In conclusion, from a large non-specialist registry of hospitalised patients, those with non-cirrhotic NAFLD had increased overall mortality compared to controls even after adjusting for CVD

    One-year outcomes of percutaneous coronary intervention in native coronary arteries versus saphenous vein grafts in patients with prior coronary artery bypass graft surgery

    Get PDF
    Background: Patients with prior coronary artery bypass graft (CABG) surgery often require percutaneous coronary intervention (PCI). Data are still limited in regards to the outcomes of native saphenous vein graft (SVG) PCI after CABG. Methods: We performed a retrospective study in a tertiary reference cardiac center of consecutive patients who underwent PCI after CABG. The data were collected for patients who underwent either native or graft PCI from January 2008 to December 2018. Arterial graft PCIs were excluded. Multivariable Cox regression analysis with propensity matching was performed, and major adverse cardiac events (MACE) outcomes including death or myocardial infarction (MI) or revascularization were assessed at 1-year after each index procedure. Results: A total of 435 PCI were performed in 401 patients (209 had native PCI and 192 had graft PCI). Target lesions were classified as following: 235 (54%) native coronary arteries and 200 (46%) SVG. Propensity matching resulted in 167 matched pairs. In multivariable Cox regression graft PCI relative to native PCI was an independent risk factor for MACE (hazard ratio [HR] 1.725, 95% confidence interval [CI] 1.049–2.837) which was primarily driven by increased incidence in revascularization (HR 2.218, 95% CI 1.193–4.122) and MI (HR 2.248, 95% CI 1.220–4.142) and with no significant difference in mortality (HR 1.118, 95% CI 0.435–2.870). Conclusions: Compared with native coronary PCI, bypass graft PCI was significantly associated with higher incidence of MACE at 1-year and this was mainly driven by MI and revascularization

    Anticoagulation for non-valvular atrial aibrillation – towards a new beginning with ximelagatran

    Get PDF
    OBJECTIVES: Ximelagatran is a novel oral direct thrombin inhibitor. It has favorable pharmacodynamic properties, with a broad therapeutic range without the need for anticoagulation monitoring. We aimed to discover whether ximelagatran offers a genuine future replacement to warfarin for patients in persistent atrial fibrillation (AF). MATERIALS AND METHODS: We provide an evidence-based review of the relative merits and disadvantages of warfarin and aspirin. We subsequently present an overview of the evidence for the utility of ximelagatran in the treatment of AF. RESULTS: Adjusted dose warfarin is recommended over aspirin for patients in AF at high risk of future stroke. Some of this benefit is partially offset by the higher bleeding risks associated with warfarin therapy. The SPORTIF III and V studies have shown that ximelagatran is not inferior to warfarin in the prevention of all strokes in patients with AF (both persistent and paroxysmal). This benefit was partially offset by the finding of a significant elevation of liver transaminases (>3 × normal) in 6% of patients. CONCLUSIONS: Current data would suggest that ximelagatran might represent a future alternative to warfarin. The lack of need for anticoagulant monitoring has been partially offset by a need for regular monitoring of liver function. Further data from randomized clinical trials is clearly needed

    Effect of remote ischaemic conditioning on clinical outcomes in patients with acute myocardial infarction (CONDI-2/ERIC-PPCI): a single-blind randomised controlled trial.

    Get PDF
    BACKGROUND: Remote ischaemic conditioning with transient ischaemia and reperfusion applied to the arm has been shown to reduce myocardial infarct size in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). We investigated whether remote ischaemic conditioning could reduce the incidence of cardiac death and hospitalisation for heart failure at 12 months. METHODS: We did an international investigator-initiated, prospective, single-blind, randomised controlled trial (CONDI-2/ERIC-PPCI) at 33 centres across the UK, Denmark, Spain, and Serbia. Patients (age >18 years) with suspected STEMI and who were eligible for PPCI were randomly allocated (1:1, stratified by centre with a permuted block method) to receive standard treatment (including a sham simulated remote ischaemic conditioning intervention at UK sites only) or remote ischaemic conditioning treatment (intermittent ischaemia and reperfusion applied to the arm through four cycles of 5-min inflation and 5-min deflation of an automated cuff device) before PPCI. Investigators responsible for data collection and outcome assessment were masked to treatment allocation. The primary combined endpoint was cardiac death or hospitalisation for heart failure at 12 months in the intention-to-treat population. This trial is registered with ClinicalTrials.gov (NCT02342522) and is completed. FINDINGS: Between Nov 6, 2013, and March 31, 2018, 5401 patients were randomly allocated to either the control group (n=2701) or the remote ischaemic conditioning group (n=2700). After exclusion of patients upon hospital arrival or loss to follow-up, 2569 patients in the control group and 2546 in the intervention group were included in the intention-to-treat analysis. At 12 months post-PPCI, the Kaplan-Meier-estimated frequencies of cardiac death or hospitalisation for heart failure (the primary endpoint) were 220 (8·6%) patients in the control group and 239 (9·4%) in the remote ischaemic conditioning group (hazard ratio 1·10 [95% CI 0·91-1·32], p=0·32 for intervention versus control). No important unexpected adverse events or side effects of remote ischaemic conditioning were observed. INTERPRETATION: Remote ischaemic conditioning does not improve clinical outcomes (cardiac death or hospitalisation for heart failure) at 12 months in patients with STEMI undergoing PPCI. FUNDING: British Heart Foundation, University College London Hospitals/University College London Biomedical Research Centre, Danish Innovation Foundation, Novo Nordisk Foundation, TrygFonden

    Diagnostics of advanced diesel fuel injectors

    No full text
    During manufacture, variations in fuel injector dimensions result in variations in fuel metering. Thus injectors need to be calibrated at the end of the production-line and then matched with engines to achieve desired fueling characteristics. Over time, injectors can wear in, resulting in changes in fuel dosing. Since measuring injected fuel quantities can be inconvenient, various estimation techniques exist. The Virtual Sensor Coefficient method for injected fuel quantity estimation is based on the concept of Bulk Modulus. This concept uses the fact that outflow of fuel from the rail at every injection event leads to corresponding measurable pressure changes inside the rail. Consequently, the magnitude of pressure change can be used to predict the change in fuel flow and hence the amount of fuel actually injected during an injection event. The most crucial parameter in this concept is Rail Pressure. It is known that disturbances in the pressure signal lead to inaccurate measurements of pressure drop. This leads to inaccurate computations of the system bulk modulus and hence the injected quantity of fuel. This project explores ways to process the pressure signal appropriately so that the pressure drops corresponding to the injection events could be measured accurately. Three methods are proposed, implemented and their results compared. These methods are the two-window based dominant frequency method, filtering using IIR filters and de-noising using wavelet transforms. It is seen that the first method is the simplest method to implement relative to the other two methods while the results obtained after using the second and the third methods are relatively better. For higher rail pressures (2000-2600 bar) the de-noising method fares the best with consistent % error numbers of +/-4 over a large range of on-times. While for the same pressure range, the two-window based dominant frequency method, on the other hand, shows % errors that fall in the range of +/-12 for the same range of on-times. This project also identifies the issues that affect the implementation of the VSC concept. These are quantization and corruption of data due to pumping effects. These are more significant at the lower rail pressures and on-times. An algorithm is devised in order to detect the pumping affected data with an aim to \u27weed-out\u27 such data and work with only the good data so that the VSC concept could give acceptable results
    corecore