538 research outputs found

    Optimizing diagnostic imaging data using LI-RADS and the Likert scale in patients with hepatocellular carcinoma

    Get PDF
    Purpose: The study aimed to compare the diagnostic performance of the Liver Imaging Reporting and Data System (LI-RADS), which incorporates fixed criteria, and the Likert scale (LS), which mainly depends on an overall impression in liver lesion diagnosis. Material and methods: Diagnostic data of 110 hepatic nodules in 103 high-risk patients for hepatocellular carcinoma (HCC) were included. Data including diameter, arterial hyperenhancement, washout, and capsule were reviewed by 2 readers using LI-RADS and LS (range, score 1-5). Inter-reader agreement (IRA), intraclass agreement (ICA), and diagnostic performance were determined by Fleiss, Cohen's k, and logistic regression, respectively. Results: There were 53 triphasic enhanced computed tomography (CT) and 50 dynamic magnetic resonance (MR) examinations. Overall, IRA was excellent (k = 0.898). IRA was good for arterial hyperenhancement (k = 0.705), washout (k = 0.763), and capsule (k = 0.771) and excellent for diameter (k = 0.981) and tumour embolus (k = 0.927). Overall, ICA between LI-RADS and LS was fair 0.32; ICA was good for scores of 1 (k = 0.682), fair for scores of 2 (k = 0.36), moderate for scores of 5 (k = 0.52), but no agreement was found for scores of 3 (k = –0.059) and 4 (k = –0.022). LIRADS produced relatively high accuracy (87.3% vs. 80%), relatively low sensitivity (84.3% vs. 98%), and significantly higher specificity (89.83% vs. 64.4%) and positive likelihood ratio (+LR: 8.29 vs. 2.75) compared to LS approach. Conclusions: LI-RADS revealed higher diagnostic accuracy as compared to LS with statistical proof higher specificity and +LR showing its ability to foretell malignancy in high-risk patients. We recommend the practical application of the LI-RADS system in the detection and treatment response monitoring of patients with HCC

    The Odd Nadarajah-Haghighi Family of Distributions: Properties and Applications

    Get PDF
    We study some mathematical properties of a new generator of continuous distributions called the Odd Nadarajah-Haghighi (ONH) family. In particular, three special models in this family are investigated, namely the ONH gamma, beta and Weibull distributions. The family density function is given as a linear combination of exponentiated densities. Further, we propose a bivariate extension and various characterization results of the new family. We determine the maximum likelihood estimates of ONH parameters for complete and censored data. We provide a simulation study to verify the precision of these estimates. We illustrate the performance of the new family by means of a real data set

    Synthesis, characterization and ab initio study of WO3 nanocubes with peculiar electrochemical properties

    Get PDF
    Simple sol–gel method has been exploited to deposit Sn-doped TiO2 thin flms on glass substrates. The resultant coatings were characterized by X-ray difraction (XRD), UV–visible techniques (UV–Vis), Fourier transform infrared spectroscopy (FTIR), and photoluminescence analysis (PL). The XRD pattern reveals an increase in crystallite size of the prepared samples with the increasing doping concentration. A decrease in doping concentrating resulted in the decrease in bandgap values. The diferent chemical bonds on these flms were identifed from their FTIR spectra. The photoluminescence analysis shows an increase in the emission peak intensity with increasing dopant concentration, and this can be attributed to the efect created due to surface states. The prepared samples were tested as antibacterial agent toward both Gram-positive and Gram-negative bacteria like S.aureus (Staphylococcus aureus) and E.coli (Escherichia coli), respectively. The size of the inhibition zones indicates that the sample shows maximum inhibitory property toward E.coli when compared to S.aureus

    Porphyrin-silica gel hybrids as effective and selective copper(II) adsorbents from industrial wastewater

    Get PDF
    Porphyrins are an important class of ligands with a tremendous ability to capture metal ions closely related to the rich coordination chemistry of porphyrins. Herein we use this characteristic to develop silica gel grafted derivatives for water remediation applications. Therefore, two porphyrin derivatives, one with three and the other with four mercaptopyridyl units were grafted on silica gel functionalized with 3-aminopropyltriethoxysilane. The new adsorbents Si3PyS and Si4PyS were characterized using a suitable set of techniques confirming the covalent attachment of the porphyrins to the silica surface. Additionally, microscopy and N2 adsorption analysis confirmed the structural integrity and preservation of the mesoporous structure of Si during surface modification. The results show that both hybrid materials exhibit good chemical and thermal stability and an outstanding Cu2+ removal capability, with a chemical adsorption capacity of 176.32 mg g–1 and 184.16 mg g–1, respectively. These materials have also been used in real water and industrial wastewater samples with minimal interference in their adsorption capabilities. Density Functional Theory calculations were performed to confirm the good performance of the hybrid materials Si3PyS and Si4PyS towards metal ions. The functionalization of silica surface with porphyrin-based ligands bearing additional binding motifs drastically improves the adsorption capability of the new hybrids towards metal ions. The presence of pyridyl units brings a meaningful advantage, since both porphyrin core and appended pyridyl groups are able of binding Cu2+ ions with high affinity, contributing to the enhancement of the chelating features of the adsorbents prepared when compared with other ligands supported in silica-based materials.publishe

    Structural analysis of ferromagnetic Mn-doped ZnO thin films deposited by radio frequency magnetron sputtering

    Get PDF
    We report on the structural analysis of ferromagnetic Mn-doped ZnO thin films deposited by radio frequency magnetron sputtering, using transmission electron microscopy (TEM), high-resolution x-ray diffraction, and Rutherford backscattering spectroscopy (RBS) measurements. The ferromagnetic Mn-doped ZnO film showed magnetization hysteresis at 5 and 300 K. A TEM analysis revealed that the Mn-doped ZnO included a high density of round-shaped cubic and elongated hexagonal MnZn oxide precipitates. The incorporation of Mn caused a large amount of structural disorder in the crystalline columnar ZnO lattice, although the wurtzite crystal structure was maintained. The observed ferromagnetism is discussed based on the structural characteristics indicated by TEM and the behavior of Mn when it is substituted into a ZnO lattice derived from RBS measurements

    Mercury goes Solid at room temperature at nanoscale and a potential Hg waste storage

    Get PDF
    While room temperature bulk mercury is liquid, it is solid in its nano-configuration (Ønano-Hg ≤ 2.5 nm). Conjugating the nano-scale size effect and the Laplace driven surface excess pressure, Hg nanoparticles of Ønano-Hg ≤ 2.4 nm embedded in a 2-D turbostratic Boron Nitride (BN) host matrix exhibited a net crystallization at room temperature via the experimentally observed (101) and (003) diffraction Bragg peaks of the solid Hg rhombohedral α-phase. The observed crystallization is correlated to a surface atomic ordering of 7 to 8 reticular atomic plans of the rhombohedral α-phase. Such a novelty of size effect on phase transition phenomena in Hg is conjugated to a potential Hg waste storage technology. Considering the vapor pressure of bulk Hg, Room Temperature (RT) Solid nano-Hg confinement could represent a potential green approach of Hg waste storage derived from modern halogen efficient light technology

    The supernova Hubble diagram for off-center observers in a spherically symmetric inhomogeneous universe

    Get PDF
    We have previously shown that spherically symmetric, inhomogeneous universe models can explain both the supernova data and the location of the first peak in the CMB spectrum without resorting to dark energy. In this work, we investigate whether it is possible to get an even better fit to the supernova data by allowing the observer to be positioned away from the origin in the spherically symmetric coordinate system. In such a scenario, the observer sees an anisotropic relation between redshifts and the luminosity distances of supernovae. The level of anisotropy allowed by the data will then constrain how far away from the origin the observer can be located, and possibly even allow for a better fit. Our analysis shows that the fit is indeed improved, but not by a significant amount. Furthermore, it shows that the supernova data do not place a rigorous constraint on how far off-center the observer can be located.Comment: 7 pages (REVTeX4), 5 figure

    Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector

    Get PDF
    The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is (2.6±0.2stat±0.4sys)×10−3(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}~events~keVee−1_{ee}^{-1}~kg−1^{-1}~day−1^{-1} in a 118~kg fiducial volume. The observed background rate is (3.6±0.4stat)×10−3(3.6\pm0.4_{\textrm{stat}})\times10^{-3}~events~keVee−1_{ee}^{-1}~kg−1^{-1}~day−1^{-1}, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.Comment: 18 pages, 12 figures / 17 images, submitted to Astropart. Phy
    • …
    corecore