72,515 research outputs found
Low-threshold analysis of CDMS shallow-site data
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the
germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments’ data as WIMP signals, and exclude new parameter space for WIMP masses between 3 and 4 GeV/c^2
Airborne thermography of temperature patterns in sugar beet piles
An investigation was conducted to evaluate the use of thermography for locating spoilage areas (chimneys) within storage piles and to subsequently use the information for the scheduling of their processing. Thermal-infrared quantitative scanner data were acquired initially on January 16, 1975, over the storage piles at Moorhead, Minnesota, both during the day and predawn. Photographic data were acquired during the day mission to evaluate the effect of uneven snow cover on the thermal emittance, and the predawn thermography was used to locate potential chimneys. The piles were examined the day prior for indications of spoilage areas, and the ground crew indicated that no spoilage areas were located using their existing methods. Nine spoilage areas were interpreted from the thermography. The piles were rechecked by ground methods three days following the flights. Six of the nine areas delineated by thermography were actual spoilage areas
Development of Auditory Selective Attention: Why Children Struggle to Hear in Noisy Environments
Children’s hearing deteriorates markedly in the presence of unpredictable noise. To explore why, 187 school-age children (4–11 years) and 15 adults performed a tone-in-noise detection task, in which the masking noise varied randomly between every presentation. Selective attention was evaluated by measuring the degree to which listeners were influenced by (i.e., gave weight to) each spectral region of the stimulus. Psychometric fits were also used to estimate levels of internal noise and bias. Levels of masking were found to decrease with age, becoming adult-like by 9–11 years. This change was explained by improvements in selective attention alone, with older listeners better able to ignore noise similar in frequency to the target. Consistent with this, age-related differences in masking were abolished when the noise was made more distant in frequency to the target. This work offers novel evidence that improvements in selective attention are critical for the normal development of auditory judgments
Recommended from our members
Reduction of internal noise in auditory perceptual learning
This paper examines what mechanisms underlie auditory perceptual learning. Fifteen normal hearing adults performed two-alternative, forced choice, pure tone frequency discrimination for four sessions. External variability was introduced by adding a zero-mean Gaussian random variable to the frequency of each tone. Measures of internal noise, encoding efficiency, bias, and inattentiveness were derived using four methods (model fit, classification boundary, psychometric function, and double-pass consistency). The four methods gave convergent estimates of internal noise, which was found to decrease from 4.52 to 2.93 Hz with practice. No group-mean changes in encoding efficiency, bias, or inattentiveness were observed. It is concluded that learned improvements in frequency discrimination primarily reflect a reduction in internal noise. Data from highly experienced listeners and neural networks performing the same task are also reported. These results also indicated that auditory learning represents internal noise reduction, potentially through the re-weighting of frequency-specific channels
The Role of Response Bias in Perceptual Learning
Sensory judgments improve with practice. Such perceptual learning is often thought to reflect an increase in perceptual sensitivity. However, it may also represent a decrease in response bias, with unpracticed observers acting in part on a priori hunches rather than sensory evidence. To examine whether this is the case, 55 observers practiced making a basic auditory judgment (yes/no amplitude-modulation detection or forced-choice frequency/amplitude discrimination) over multiple days. With all tasks, bias was present initially, but decreased with practice. Notably, this was the case even on supposedly “bias-free,” 2-alternative forced-choice, tasks. In those tasks, observers did not favor the same response throughout (stationary bias), but did favor whichever response had been correct on previous trials (nonstationary bias). Means of correcting for bias are described. When applied, these showed that at least 13% of perceptual learning on a forced-choice task was due to reduction in bias. In other situations, changes in bias were shown to obscure the true extent of learning, with changes in estimated sensitivity increasing once bias was corrected for. The possible causes of bias and the implications for our understanding of perceptual learning are discussed
Recommended from our members
Learning to detect a tone in unpredictable noise
Eight normal-hearing listeners practiced a tone-detection task in which a 1-kHz target was masked by a spectrally unpredictable multitone complex. Consistent learning was observed, with mean masking decreasing by 6.4 dB over five sessions (4500 trials). Reverse-correlation was used to estimate how listeners weighted each spectral region. Weight-vectors approximated the ideal more closely after practice, indicating that listeners were learning to attend selectively to the task relevant information. Once changes in weights were accounted for, no changes in internal noise (psychometric slope) were observed. It is concluded that this task elicits robust learning, which can be understood primarily as improved selective attention
Method for prediction of pump cavitation performance for various liquids, liquid temperatures, and rotative speeds
Prediction of cavitation performance of centrifugal pump
Combined limits on WIMPs from the CDMS and EDELWEISS experiments
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614  kg·days equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent weakly interacting, massive particle (WIMP)-nucleon cross section. For a WIMP mass of 90  GeV/c^2, where this analysis is most sensitive, a cross section of 3.3×10^(-44)  cm^2 is excluded at 90% C.L. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700  GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others
- …