32 research outputs found

    Unexpected Behavior of the Hydrogen Oxidation Reaction on Palladium in Alkaline Solution: A Feasible Kinetic Explanation

    Get PDF
    The hydrogen oxidation reaction was studied on a thin film palladium electrode supported on a gold substrate in alkaline solution. The hydrogen absorption process was analyzed by open circuit potential transient and the current - overpotential dependences were obtained by chronoamperometry at different rotation rates in a solution saturated with hydrogen. The results obtained show anunexpected profile at low overpotentials, where current decreases as rotation rate increases. A kinetic mechanism was proposed to interpret this behavior and the corresponding equations were derived. They were used to correlate the results, with a good agreement between the experimental and fitted curves.Fil: Montero, María de Los Angeles. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Programa de Electroquímica Aplicada e Ingeniería Electroquímica; ArgentinaFil: Gennero, Maria Rosa. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Programa de Electroquímica Aplicada e Ingeniería Electroquímica; ArgentinaFil: Chialvo, Abel Cesar. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Programa de Electroquímica Aplicada e Ingeniería Electroquímica; Argentin

    Estudio de la reacción de electrooxidación de acido fórmico sobre Iridio usando una celda de flujo

    Get PDF
    Estudios recientes de la reacción de electrooxidación de ácido fórmico (FAO) mediante la determinación simultanea de la dependencia corriente-potencial en estado estacionario y del cubrimiento de monóxido de carbono adsorbido COad, han permitido aportar nueva evidencia para la comprensión de los procesos elementales involucrados en las misma [1-3]. Se ha observado que la FAO sobre Pd [3] presenta un comportamiento cinético marcadamente diferente a los observados sobre Pt [1] y Rh [3]. En este contexto, en el presente trabajo se estudia la FAO sobre iridio, metal que se caracteriza por la adsorción de oxhidrilo OHad a bajos potenciales.Fil: Montero, María de Los Angeles. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; ArgentinaFil: Gennero, Maria Rosa. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; ArgentinaFil: Chialvo, Abel Cesar. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; ArgentinaXXII Congreso Argentino de Fisicoquímica y Química InorgánicaLa PlataArgentinaAsociación Argentina de Investigación FisicoquímicaUniversidad Nacional de la Plata. Facultad de Ingenierí

    Métodos diagnósticos laboratoriais e de imagem na síndrome de Zollinger-Ellison

    Get PDF
    Introduction: Zollinger-Ellison syndrome is a neuroendocrine tumor that produces hypersecretion of gastric acid and peptic ulcer. Therefore, the review was carried out with the objective of describing the main laboratory and imaging diagnostic methods in Zollinger-Ellison syndrome.Development: a bibliographic review was carried out with the descriptors in Spanish and English "Zollinger-Ellison syndrome", "neuroendocrine tumor" and gastrinoma, taken from the descriptors in health sciences (DeCS / MeSH), in Google databases. Academic, SciELO and National Library of Medicine. As results, it was obtained that the laboratory methods are fasting basal serum gastrin, which is not reliable due to its alteration in different diseases, gastric pH, excludes secondary hypergastrinemias, and basal acid gastric secretion, which differentiates the forms of hypergastrinemia. These laboratory tests are complementary to each other, and to perform them, the intake of proton pump inhibitors must be suspended. Other tests include the secretin stimulation test, which confirms hypergastrinemia, and the calcium stimulation test, which diagnoses tumors >1 mm that express calcium receptors. Imaging methods are essential for tumor localization. The first imaging technique to be performed due to its high sensitivity and specificity is 111In-octreotide scintigraphy, which locates tumors not detected with other examinations and allows differential diagnosis with hypervascularized lesions.Conclusions: Zollinger-Ellison syndrome requires the use of novel laboratory and imaging methods for an accurate diagnosis.Introducción: el síndrome de Zollinger - Ellison es un tumor neuroendocrino que produce hipersecreción de ácido gástrico y úlcera péptica. Por lo que se realizó la revisión con el objetivo de describir los principales métodos diagnósticos de laboratorio e imagenológicos en el síndrome de Zollinger – Ellison.Desarrollo: se realizó una revisión bibliográfica con los descriptores en español e inglés “síndrome de Zollinger-Ellison”, “tumor neuroendocrino” y gastrinoma, sacados de los descriptores en ciencias de la salud (DeCS/MeSH), en las bases de datos Google Académico, SciELO y National Library of Medicine. Como resultados se obtuvo que los métodos de laboratorio son la gastrina sérica basal en ayunas, la cual no es confiable debido a su alteración en diferentes enfermedades, el pH gástrico, excluye hipergastrinemias secundarias, y la secreción gástrica ácida basal, que diferencia las formas de hipergastrinemia. Estos análisis de laboratorio son complementarios entre sí, y para su realización se debe suspender la toma de los inhibidores de la bomba de protones. Otros estudios son la prueba de estimulación por secretina, que confirma la hipergastrinemia, y la prueba de estimulación por calcio, que diagnostica tumores > 1 mm que expresan receptores de calcio. Los métodos imagenológicos son fundamentales para la localización del tumor. La primera técnica de imagen que se debe realizar debido a su alta sensibilidad y especificidad es la gammagrafía con 111In-octreótido, esta localiza tumores no detectados con otras exploraciones y permite realizar el diagnóstico diferencial con lesiones hipervascularizadas. Conclusiones: el síndrome de Zollinger-Ellison requiere para un diagnóstico certero la utilización de métodos de laboratorio y de imagen novedosos.  Introdução: a síndrome de Zollinger-Ellison é um tumor neuroendócrino que produz hipersecreção de ácido gástrico e úlcera péptica. Portanto, a revisão foi realizada com o objetivo de descrever os principais métodos de diagnóstico laboratorial e de imagem na síndrome de Zollinger-Ellison.Desenvolvimento: foi realizada revisão bibliográfica com os descritores em espanhol e inglês "Síndrome de Zollinger-Ellison", "tumor neuroendócrino" e gastrinoma, retirados dos descritores em ciências da saúde (DeCS/MeSH), nas bases de dados do Google. Acadêmico, SciELO e Biblioteca Nacional de Medicina. Como resultados, obteve-se que os métodos laboratoriais são a gastrina sérica basal em jejum, o que não é confiável devido à sua alteração em diferentes doenças, pH gástrico, exclui hipergastrinemias secundárias, e secreção gástrica ácida basal, o que diferencia as formas de hipergastrinemia. Esses exames laboratoriais são complementares entre si e, para realizá-los, deve-se suspender a ingestão de inibidores da bomba de prótons. Outros exames incluem o teste de estimulação de secretina, que confirma a hipergastrinemia, e o teste de estimulação de cálcio, que diagnostica tumores >1 mm que expressam receptores de cálcio. Os métodos de imagem são essenciais para a localização do tumor. A primeira técnica de imagem a ser realizada devido à sua alta sensibilidade e especificidade é a cintilografia com 111In-octreotide, que localiza tumores não detectados com outros exames e permite o diagnóstico diferencial com lesões hipervascularizadas.Conclusões: a síndrome de Zollinger-Ellison requer o uso de novos métodos laboratoriais e de imagem para um diagnóstico preciso

    Infection by SARS-CoV-2 in hypertensive patients, nonsystematic revision

    Get PDF
    Introducción: La hipertensión arterial es la comorbilidad cardiovascular más prevalente, en los pacientes infectados, por la COVID-19. Objetivo: Describir los mecanismos de la hipertensión arterial, con la gravedad de la infección viral por SARS-CoV-2. Métodos:Las bases de datos seleccionadas fueron: PubMed, Scientific Electronic Library Online, Scielo y Google Académico. Se realizó una revisión independiente y se propusieron 50 referencias. No se pusieron restricciones en cuanto al tipo de trabajo, en idioma español e inglés. Se seleccionaron 44 referencias de la propuesta inicial, por mayoría simple.Conclusiones:La hipertensión arterial aumenta el riesgo de hospitalización y muerte, por la COVID-19. Se explica la enfermedad e infección por SARS-CoV-2 que coexiste con la hipertensión, entre los que se destacan el papel de la enzima convertidora de angiotensina 2, los trastornos del sistema renina-angiotensina-aldosterona, la disfunción inmune con excesiva inflamación y la disfunción gastrointestinal. Introduction: Hypertension is the most prevalent cardiovascular comorbidity in patients infected by COVID-19. Objective: To describe hypertension mechanisms, with the critical status of the viral infection by SARS-CoV-2. Methods: The selected data Bases were: PubMed, Scientific Electronic Library Online, Scielo and Google Scholar. An independent revision was carried out and 50 references were proposed. There were no restrictions about the type of paper, in Spanish and English. 44 references were selected of the initial proposal, by simple majority.Conclusions:That hypertension increases the risk of admission and death by COVID-19. It has been explained the disease and infection by SARS-CoV-2 that coexist with hypertension.  The role of the enzyme converter of angiotensin 2, the disorders of the system renin-angiotensin-aldosterone, the immune dysfunction with excessive inflammation and the gastrointestinal dysfunction have been distinguished.

    Infección por el SARS-CoV-2 en pacientes hipertensos, revisión no sistemática

    Get PDF
    Introducción: La hipertensión arterial es la comorbilidad cardiovascular más prevalente, en los pacientes infectados, por la COVID-19. Objetivo: Describir los mecanismos de la hipertensión arterial, con la gravedad de la infección viral por SARS-CoV-2. Métodos: Las bases de datos seleccionadas fueron: PubMed, Scientific Electronic Library Online, Scielo y Google Académico. Se realizó una revisión independiente y se propusieron 50 referencias. No se pusieron restricciones en cuanto al tipo de trabajo, en idioma español e inglés. Se seleccionaron 44 referencias de la propuesta inicial, por mayoría simple. Conclusiones: La hipertensión arterial aumenta el riesgo de hospitalización y muerte, por la COVID-19. Se explica la enfermedad e infección por SARS-CoV-2 que coexiste con la hipertensión, entre los que se destacan el papel de la enzima convertidora de angiotensina 2, los trastornos del sistema renina-angiotensina-aldosterona, la disfunción inmune con excesiva inflamación y la disfunción gastrointestinal

    Neonatal pneumonia associated with mechanical ventilation, some risk factors

    Get PDF
    Introducción: los problemas respiratorios constituyen una importante causa de mortalidad y morbilidad en el recién nacido.Objetivo: identificar los factores de riesgo para la neumonía asociada a la ventilación mecánica artificial invasiva en los recién nacidos ingresados en la UCIN del servicio de Neonatología del Hospital General Docente Carlos M. de Céspedes de enero 2012 hasta enero 2015.Método: se realizó un estudio analítico de casos y controles. Los grupos de estudio estuvieron conformados por 75 casos y 150 controles respectivamente. La evaluación de las asociaciones se realizó por la regresión logística binariaResultados: las variables edad gestacional antes las 37 semanas de gestación, el bajo peso al nacer poseen dos veces o más de riesgos de padecer una neumonía asociada a la ventilación de forma significativa, p<0,05; entre los diagnósticos que llevaron a la ventilación mecánica la sepsis grave con una p: 0,04; en  los resultados correspondientes al análisis multivariado, se encontró que los neonatos con más de 72 horas de ventilación, incrementaron la posibilidad de contraer la neumonía asociada a la ventilación con un OR=72,831  ± IC 95%  9,374 – 565,858, un valor de p=0,000 el sexo, y el tipo de partos no fueron significativos.Conclusión: La edad gestacional menor de 37 semanas, el peso al nacer menor de 2500 gramos, el tiempo ventilatorio de más de 3 días y el diagnóstico de sepsis grave fueron las variables significativas. El sexo y tipo de parto no fueron significativas.Background: respiratory problems are an important cause of mortality and morbidity in the new-born.Objective: to identify the risk factors for pneumonia associated with invasive artificial mechanical ventilation in new-borns admitted to the NICU of the Neonatology service of the Carlos M. de Céspedes General Teaching Hospital from January 2012 to January 2015.Method: an analytical study of cases and controls was carried out. The study groups consisted of 75 cases and 150 controls, respectively. The evaluation of the associations was carried out by the binary logistic regressionResults: the variables gestational age before 37 weeks of gestation, the low weight at birth have twice or more risks of suffering pneumonia associated with ventilation significantly, p <0,05; among the diagnoses that led to mechanical ventilation severe sepsis with a p: 0,04; In the results corresponding to the multivariate analysis, it was found that neonates with more than 72 hours of ventilation increased the possibility of contracting pneumonia associated with ventilation with an OR = 72,831 ± 95% CI 9.374 – 565,858, a value of p = 0,000 sex, and the type of deliveries were not significant.Conclusion: the gestational age less than 37 weeks, the weight at birth less than 2500 grams, the ventilator time of more than 3 days and the diagnosis of severe sepsis were the significant variables. Sex and type of delivery were not significant

    Towards an efficient liquid organic hydrogen carrier fuel cell concept

    Get PDF
    The high temperature required for hydrogen release from Liquid Organic Hydrogen Carrier (LOHC) systems has been considered in the past as the main drawback of this otherwise highly attractive and fully infrastructure-compatible form of chemical hydrogen storage. According to the state-of-the art, the production of electrical energy from LOHC-bound hydrogen, e.g. from perhydro-dibenzyltoluene (H18DBT), requires provision of the dehydrogenation enthalpy (e.g. 65 kJ mol-1(H2) for H18-DBT) at a temperature level of 300 °C followed by purification of the released hydrogen for subsequent fuel cell operation. Here, we demonstrate that a combination of a heterogeneously catalysed transfer hydrogenation from H18-DBT to acetone and fuel cell operation with the resulting 2-propanol as a fuel, allows for an electrification of LOHC-bound hydrogen in high efficiency (> 50 %) and at surprisingly mild conditions (temperatures below 200 °C). Most importantly, our proposed new sequence does not require an external heat input as the transfer hydrogenation from H18-DBT to acetone is almost thermoneutral. In the PEMFC operation with 2-propanol, the endothermal proton release at the anode is compensated by the exothermic formation of water. Ideally the proposed sequence does not form and consume molecular H2 at any point which adds a very appealing safety feature to this way of producing electricity from LOHC-bound hydrogen, e.g. for applications on mobile platforms.Fil: Sievi, Gabriel. Forschungszentrum Jülich; AlemaniaFil: Geburtig, Denise. Universitat Erlangen-Nuremberg; AlemaniaFil: Skeledzic, Tanja. Forschungszentrum Jülich; AlemaniaFil: Bösmann, Andreas. Universitat Erlangen-Nuremberg; AlemaniaFil: Preuster, Patrick. Forschungszentrum Jülich; AlemaniaFil: Brummel, Olaf. Universitat Erlangen-Nuremberg; AlemaniaFil: Waidhas, Fabian. Universitat Erlangen-Nuremberg; AlemaniaFil: Montero, María de Los Angeles. Universidad Nacional del Litoral. Instituto de Química Aplicada del Litoral. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Química Aplicada del Litoral.; ArgentinaFil: Khanipour, Peyman. Forschungszentrum Jülich; AlemaniaFil: Katsounaros, Ioannis. Forschungszentrum Jülich; AlemaniaFil: Libuda, Jörg. Universitat Erlangen-Nuremberg; AlemaniaFil: Mayrhofer, Karl J. J.. Forschungszentrum Jülich; AndorraFil: Wasserscheid, Peter. Universitat Erlangen-Nuremberg; Alemani

    Spatiotemporal Characteristics of the Largest HIV-1 CRF02_AG Outbreak in Spain: Evidence for Onward Transmissions

    Get PDF
    Background and Aim: The circulating recombinant form 02_AG (CRF02_AG) is the predominant clade among the human immunodeficiency virus type-1 (HIV-1) non-Bs with a prevalence of 5.97% (95% Confidence Interval-CI: 5.41–6.57%) across Spain. Our aim was to estimate the levels of regional clustering for CRF02_AG and the spatiotemporal characteristics of the largest CRF02_AG subepidemic in Spain.Methods: We studied 396 CRF02_AG sequences obtained from HIV-1 diagnosed patients during 2000–2014 from 10 autonomous communities of Spain. Phylogenetic analysis was performed on the 391 CRF02_AG sequences along with all globally sampled CRF02_AG sequences (N = 3,302) as references. Phylodynamic and phylogeographic analysis was performed to the largest CRF02_AG monophyletic cluster by a Bayesian method in BEAST v1.8.0 and by reconstructing ancestral states using the criterion of parsimony in Mesquite v3.4, respectively.Results: The HIV-1 CRF02_AG prevalence differed across Spanish autonomous communities we sampled from (p &lt; 0.001). Phylogenetic analysis revealed that 52.7% of the CRF02_AG sequences formed 56 monophyletic clusters, with a range of 2–79 sequences. The CRF02_AG regional dispersal differed across Spain (p = 0.003), as suggested by monophyletic clustering. For the largest monophyletic cluster (subepidemic) (N = 79), 49.4% of the clustered sequences originated from Madrid, while most sequences (51.9%) had been obtained from men having sex with men (MSM). Molecular clock analysis suggested that the origin (tMRCA) of the CRF02_AG subepidemic was in 2002 (median estimate; 95% Highest Posterior Density-HPD interval: 1999–2004). Additionally, we found significant clustering within the CRF02_AG subepidemic according to the ethnic origin.Conclusion: CRF02_AG has been introduced as a result of multiple introductions in Spain, following regional dispersal in several cases. We showed that CRF02_AG transmissions were mostly due to regional dispersal in Spain. The hot-spot for the largest CRF02_AG regional subepidemic in Spain was in Madrid associated with MSM transmission risk group. The existence of subepidemics suggest that several spillovers occurred from Madrid to other areas. CRF02_AG sequences from Hispanics were clustered in a separate subclade suggesting no linkage between the local and Hispanic subepidemics
    corecore