9 research outputs found

    Association of kidney disease measures with risk of renal function worsening in patients with type 1 diabetes

    Get PDF
    Background: Albuminuria has been classically considered a marker of kidney damage progression in diabetic patients and it is routinely assessed to monitor kidney function. However, the role of a mild GFR reduction on the development of stage 653 CKD has been less explored in type 1 diabetes mellitus (T1DM) patients. Aim of the present study was to evaluate the prognostic role of kidney disease measures, namely albuminuria and reduced GFR, on the development of stage 653 CKD in a large cohort of patients affected by T1DM. Methods: A total of 4284 patients affected by T1DM followed-up at 76 diabetes centers participating to the Italian Association of Clinical Diabetologists (Associazione Medici Diabetologi, AMD) initiative constitutes the study population. Urinary albumin excretion (ACR) and estimated GFR (eGFR) were retrieved and analyzed. The incidence of stage 653 CKD (eGFR < 60 mL/min/1.73 m2) or eGFR reduction > 30% from baseline was evaluated. Results: The mean estimated GFR was 98 \ub1 17 mL/min/1.73m2 and the proportion of patients with albuminuria was 15.3% (n = 654) at baseline. About 8% (n = 337) of patients developed one of the two renal endpoints during the 4-year follow-up period. Age, albuminuria (micro or macro) and baseline eGFR < 90 ml/min/m2 were independent risk factors for stage 653 CKD and renal function worsening. When compared to patients with eGFR > 90 ml/min/1.73m2 and normoalbuminuria, those with albuminuria at baseline had a 1.69 greater risk of reaching stage 3 CKD, while patients with mild eGFR reduction (i.e. eGFR between 90 and 60 mL/min/1.73 m2) show a 3.81 greater risk that rose to 8.24 for those patients with albuminuria and mild eGFR reduction at baseline. Conclusions: Albuminuria and eGFR reduction represent independent risk factors for incident stage 653 CKD in T1DM patients. The simultaneous occurrence of reduced eGFR and albuminuria have a synergistic effect on renal function worsening

    The estimation of glomerular filtration rate in type 2 diabetic patients may depend on the equation used,

    No full text
    Background: The aim of this study was to compare the estimation of glomerular filtration rate (GFR) in type 2 diabetes mellitus (DM) outpatients. Methods: The study included 1686 subjects, aged 68±10 years. GFR was evaluated with five different equations: GFRMDRD186, GFRMDRD175, GFRCKD-EPI, GFRMAYO, GFRCG. Results: GFR was lower than 60 ml min-1 kg-1 in 456 patients (27%) by GFRMDRD186, in 531 (31.5%) by GFRMDRD175, in 504 (30%) by GFRCKD-EPI, in 433 (26%) by GFRC-G, and in 255 (15%) by GFRMAYO. The mean differences in measuring GFR with the different formulae ranged from 1.03±6.20 to -14.5±11.9 ml min-1 1.73 m2-1. Conclusions: The evaluation of GFR with different formulae in type 2 DM patients may identify different chronic kidney disease (CKD) stages. Physicians could take advantage by the knowledge of the formula used for evaluation of renal function, for a better interpretation of values and a more appropriate use in the everyday clinical practice

    Prescription of oral antidiabetic drugs in K/DIGO chronic kidney disease stage 3 and 4: a single centre report.

    No full text
    AIM: Evaluation of chronic kidney disease (CKD) is essential in order to prescribe properly oral antidiabetic drugs (OADs). The aim of our study was to report hypoglycemic drugs prescription to CKD in a cohort of type 2 diabetes mellitus (DM) outpatients. METHODS: This survey included 1686 outpatients with type 2 DM treated with OADs who were not taking insulin evaluated by a team of diabetologists. Glomerular filtration rate (GFR) was calculated by the CKD-EPI formula and subjects were classified in the K/DIGO stages. Main clinical parameters were also evaluated. RESULTS: Patients were aged 68±10 years, 57.1% were males, Body Mass Index was 30±5 kg/m2, glycated hemoglobin 8±1%, systolic and diastolic blood pressure values were 138±15/80±9 mmHg. Serum creatinine was 1.03±0.35 mg/dL and GFR 71±21 mL/min/1.73 m2. In 504 patients (30%) GFR was lower than 60 mL/min/1.73 m2. The different treatment groups had different GFR and hypoglycaemic drugs were prescribed differently in the different K/DIGO stages. The majority of subjects in stage 3A and 3B were treated with repaglinide, however a significant percentage of them were treated with metformin and sulfonylureas. Nearly half of subjects with CKD stage 4 were treated with metformin and sulfonylureas. CONCLUSION: In this report we found that nearly one third of patients with type DM 2 had CKD and in a significant percentage of them OADs were prescribed even if they were in K/DIGO CKD stage 3 and 4

    Subcutaneous insulin infusion (CSII) in italy: The third national survey

    No full text
    Continuous subcutaneous insulin infusion (CSII) is increasingly being used worldwide, mostly thanks to technical improvements. This study examined the current status of CSII in Italy. Physicians in charge of 272 diabetes centers caring for patients using CSII were sent a questionnaire investigating clinical features, pump technology and management of these patients; a large proportion (217 centers, 79.8%) joined the study. By end-April 2013, data had been collected on 10152 patients treated with CSII; 98.2% had type 1 diabetes, 82.4% were adults, 57% female. Only just over half the centers (59%) managed more than 20 CSII patients each. The distribution of patients varied widely both among and within different regions. The main indication for CSII was the de- sire to improve glycemic control. Dropouts (8.65%) were mainly due to difficulties with pump wearability or non-optimal glycemic control. Among CSII patients 61% used a traditional pump, 39% a sensor augmented pump. Only 68% used the CSII advanced functions and glucose sensors were used twelve days per month on average. Round-the-clock assistance was guaranteed in 81% of centers; a full diabetes team followed patients in only 40% of adult-care centers and 50% of pediatric units. CSII is increasingly used in Italy, by adults and pediatric patients. However, further work is needed to unify treatment strategies throughout the country and to encourage optimal pump use and applications

    La terapia insulinica sottocutanea continua (CSII) in Italia. Terza indagine nazionale

    No full text
    Continuous subcutaneous insulin infusion (CSII) is increasingly being used worldwide, mostly thanks to technical improvements. This study examined the current status of CSII in Italy. Physicians in charge of 272 diabetes centers caring for patients using CSII were sent a questionnaire investigating clinical features, pump technology and management of these patients; a large proportion (217 centers, 79.8%) joined the study. By end-April 2013, data had been collected on 10152 patients treated with CSII; 98.2% had type 1 diabetes, 82.4% were adults, 57% female. Only just over half the centers (59%) managed more than 20 CSII patients each. The distribution of patients varied widely both among and within different regions. The main indication for CSII was the de- sire to improve glycemic control. Dropouts (8.65%) were mainly due to difficulties with pump wearability or non-optimal glycemic control. Among CSII patients 61% used a traditional pump, 39% a sensor augmented pump. Only 68% used the CSII advanced functions and glucose sensors were used twelve days per month on average. Round-the-clock assistance was guaranteed in 81% of centers; a full diabetes team followed patients in only 40% of adult-care centers and 50% of pediatric units. CSII is increasingly used in Italy, by adults and pediatric patients. However, further work is needed to unify treatment strategies throughout the country and to encourage optimal pump use and applications

    Continuous subcutaneous insulin infusion in Italy: third national survey.

    No full text
    BACKGROUND: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. MATERIALS AND METHODS: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. RESULTS: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+nurse+dietician+psychologist) was available in 23% of adult-care diabetes centers and in 53% of pediatric diabetes units. CONCLUSIONS: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use

    La terapia insulinica sottocutanea continua (CSII) in Italia. Terza indagine nazionale

    No full text
    Continuous subcutaneous insulin infusion (CSII) is increasingly being used worldwide, mostly thanks to technical improvements. This study examined the current status of CSII in Italy. Physicians in charge of 272 diabetes centers caring for patients using CSII were sent a questionnaire investigating clinical features, pump technology and management of these patients; a large proportion (217 centers, 79.8%) joined the study. By end-April 2013, data had been collected on 10152 patients treated with CSII; 98.2% had type 1 diabetes, 82.4% were adults, 57% female. Only just over half the centers (59%) managed more than 20 CSII patients each. The distribution of patients varied widely both among and within different regions. The main indication for CSII was the de- sire to improve glycemic control. Dropouts (8.65%) were mainly due to difficulties with pump wearability or non-optimal glycemic control. Among CSII patients 61% used a traditional pump, 39% a sensor augmented pump. Only 68% used the CSII advanced functions and glucose sensors were used twelve days per month on average. Round-the-clock assistance was guaranteed in 81% of centers; a full diabetes team followed patients in only 40% of adult-care centers and 50% of pediatric units. CSII is increasingly used in Italy, by adults and pediatric patients. However, further work is needed to unify treatment strategies throughout the country and to encourage optimal pump use and applications

    Continuous subcutaneous insulin infusion in Italy: Third National Survey

    No full text
    Background: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. Materials and Methods: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. Results: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+nurse+dietician+psychologist) was available in 23% of adult-care diabetes centers and in 53% of pediatric diabetes units. Conclusions: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use
    corecore