270 research outputs found

    Molybdenum sound velocity and shear modulus softening under shock compression

    Get PDF
    We measured the longitudinal sound velocity in Mo shock compressed up to 4.4 Mbars on the Hugoniot. Its sound speed increases linearly with pressure up to 2.6 Mbars; the slope then decreases up to the melting pressure of ∼3.8 Mbars. This suggests a decrease of shear modulus before the melt. A linear extrapolation of our data to 1 bar agrees with the ambient sound speed. The results suggest that Mo remains in the bcc phase on the Hugoniot up to the melting pressure. There is no statistically significant evidence for a previously reported bcc→hcp phase transition on the Hugoniot

    Reply to “Comment on ‘Molybdenum sound velocity and shear modulus softening under shock compression’ ”

    Get PDF
    We respond to the Comment by Errandonea et al. [Phys. Rev. B 92, 026101 (2015)] on their reinterpretation of our published data [Nguyen et al., Phys. Rev. B 89, 174109 (2014)]. In the original paper, we argued that there is no solid-solid phase transition along the Hugoniot at 2.1 Mbars. There is, however, a softening of the shear modulus starting at 2.6 Mbars. Errandonea et al. [Phys. Rev. B 92, 026101 (2015)] reinterpreted our data and concluded that there is a structural change near 2.3 Mbars on the Hugoniot. We will explore the differences and agreements in the two interpretations of our data

    Tantalum sound velocity under shock compression

    Get PDF
    We used several variations of the shock compression method to measure the longitudinal sound velocity of shocked tantalum over the pressure range 37–363 GPa with a typical uncertainty of 1.0%%. These data are consistent with Ta remaining in the bcc phase along the principal Hugoniot from ambient pressure to ≈300 GPa, at which pressure melting occurs. These data also do not support the putative melting phenomena reported below 100 GPa in some static compression experiments

    Tantalum sound velocity under shock compression

    Get PDF
    We used several variations of the shock compression method to measure the longitudinal sound velocity of shocked tantalum over the pressure range 37–363 GPa with a typical uncertainty of 1.0%%. These data are consistent with Ta remaining in the bcc phase along the principal Hugoniot from ambient pressure to ≈300 GPa, at which pressure melting occurs. These data also do not support the putative melting phenomena reported below 100 GPa in some static compression experiments

    How clusters create shared value in rural areas: An examination of six case studies

    Get PDF
    The main aim of this paper is to demonstrate that clusters can support the sustainable development of rural areas through the creation of shared value. This is done via the close examination of six different cases of rural clusters in Greece, Italy, Germany, Poland, Denmark, and Sweden. Qualitative as well as quantitative data were taken from the clusters, which demonstrated that their main business approaches naturally coincided with the creation of economic, social, and environmental benefits for the local communities in which they operated. The case clusters were created in a top-down manner, aimed at boosting regional R&D activities and making the local economy more competitive and more sustainable. However, private initiative took over and al-lowed these clusters to flourish because meeting the regions’ economic, social, and environmental needs successfully coincided with the target of the clusters’ own development and profitability. The results show that clusters, with their potential for shared value creation, can constitute a powerful engine for the revitalisation and development of rural areas, addressing the significant challenges which they are currently facing

    Application of Al-Cu-W-Ta graded density impactors in dynamic ramp compression experiments

    Get PDF
    Graded density impactors (GDIs) are used to dynamically compress materials to extreme conditions. Two modifications to a previously developed Mg-Cu-W GDI are made in this work before using it in a dynamic compression experiment: Mg is replaced with Al and a Ta disk is glued to the back. The Mg phase is replaced by Al because FCC Al remains solid to higher pressure along its Hugoniot compared to Mg. The addition of the Ta disk creates a constant particle velocity regime and facilitates a definition of peak pressure states. Microstructure analysis, profilometry, and ultrasonic C-scans of the Al-Cu-W GDI all confirm excellent uniformity. We evaluated signal variation in the radial direction of a dynamically compressed Al-LiF bilayer target to evaluate the contribution of spatial nonuniformity to errors. Velocity traces from five photon Doppler velocimetry (PDV) probes located at different radial distances from the center of the target varied at most by 1.1% with a root mean square of 0.3% during the compression ramp, demonstrating low PDV measurement error over a relatively large experimental area. The experimental PDV data also agrees well with 1D simulations that use inputs from predictive characterization models developed for the material properties resulting from tape casting, laminating, and powder consolidation processes. Low measurement error during quasi-isentropic compression, leading to better precision, ensures a robust platform to reach extreme compression and low-temperature recovery states and facilitates discovery via synthesis, quenching, and preservation of new high-pressure phases

    Application of Al-Cu-W-Ta graded density impactors in dynamic ramp compression experiments

    Get PDF
    Graded density impactors (GDIs) are used to dynamically compress materials to extreme conditions. Two modifications to a previously developed Mg-Cu-W GDI are made in this work before using it in a dynamic compression experiment: Mg is replaced with Al and a Ta disk is glued to the back. The Mg phase is replaced by Al because FCC Al remains solid to higher pressure along its Hugoniot compared to Mg. The addition of the Ta disk creates a constant particle velocity regime and facilitates a definition of peak pressure states. Microstructure analysis, profilometry, and ultrasonic C-scans of the Al-Cu-W GDI all confirm excellent uniformity. We evaluated signal variation in the radial direction of a dynamically compressed Al-LiF bilayer target to evaluate the contribution of spatial nonuniformity to errors. Velocity traces from five photon Doppler velocimetry (PDV) probes located at different radial distances from the center of the target varied at most by 1.1% with a root mean square of 0.3% during the compression ramp, demonstrating low PDV measurement error over a relatively large experimental area. The experimental PDV data also agrees well with 1D simulations that use inputs from predictive characterization models developed for the material properties resulting from tape casting, laminating, and powder consolidation processes. Low measurement error during quasi-isentropic compression, leading to better precision, ensures a robust platform to reach extreme compression and low-temperature recovery states and facilitates discovery via synthesis, quenching, and preservation of new high-pressure phases

    γ-Secretase modulators show selectivity for γ-secretase–mediated amyloid precursor protein intramembrane processing

    Get PDF
    The aggregation of β-amyloid peptide 42 results in the formation of toxic oligomers and plaques, which plays a pivotal role in Alzheimer's disease pathogenesis. Aβ42 is one of several Aβ peptides, all of Aβ30 to Aβ43 that are produced as a result of γ-secretase–mediated regulated intramembrane proteolysis of the amyloid precursor protein. γ-Secretase modulators (GSMs) represent a promising class of Aβ42-lowering anti-amyloidogenic compounds for the treatment of AD. Gamma-secretase modulators change the relative proportion of secreted Aβ peptides, while sparing the γ-secretase–mediated processing event resulting in the release of the cytoplasmic APP intracellular domain. In this study, we have characterized how GSMs affect the γ-secretase cleavage of three γ-secretase substrates, E-cadherin, ephrin type A receptor 4 (EphA4) and ephrin type B receptor 2 (EphB2), which all are implicated in important contexts of cell signalling. By using a reporter gene assay, we demonstrate that the γ-secretase–dependent generation of EphA4 and EphB2 intracellular domains is unaffected by GSMs. We also show that γ-secretase processing of EphA4 and EphB2 results in the release of several Aβ-like peptides, but that only the production of Aβ-like proteins from EphA4 is modulated by GSMs, but with an order of magnitude lower potency as compared to Aβ modulation. Collectively, these results suggest that GSMs are selective for γ-secretase–mediated Aβ production

    Development of fluorescent probes for bioimaging applications

    Get PDF
    Fluorescent probes, which allow visualization of cations such as Ca2+, Zn2+ etc., small biomolecules such as nitric oxide (NO) or enzyme activities in living cells by means of fluorescence microscopy, have become indispensable tools for clarifying functions in biological systems. This review deals with the general principles for the design of bioimaging fluorescent probes by modulating the fluorescence properties of fluorophores, employing mechanisms such as acceptor-excited Photoinduced electron Transfer (a-PeT), donor-excited Photoinduced electron Transfer (d-PeT), and spirocyclization, which have been established by our group. The a-PeT and d-PeT mechanisms are widely applicable for the design of bioimaging probes based on many fluorophores and the spirocyclization process is also expected to be useful as a fluorescence off/on switching mechanism. Fluorescence modulation mechanisms are essential for the rational design of novel fluorescence probes for target molecules. Based on these mechanisms, we have developed more than fifty bioimaging probes, of which fourteen are commercially available. The review also describes some applications of the probes developed by our group to in vitro and in vivo systems

    Isothermal folding of G-quadruplexes

    Get PDF
    Thermodynamic studies of G-quadruplex stability are an essential complement to structures obtained by NMR or x-ray crystallography. An understanding of the energetics of quadruplex folding provides a necessary foundation for the physical interpretation of quadruplex formation and reactivity. While thermal denaturation methods are most commonly used to evaluate quadruplex stability, it is also possible to study folding using isothermal titration methods. G-quadruplex folding is tightly coupled to specific cation binding. We describe here protocols for monitoring the cation-driven quadruplex folding transition using circular dichroism or absorbance, and for determination of the distribution of free and bound cation using a fluorescence indicator. Together these approaches provide insight into quadruplex folding at constant temperature, and characterize the linkage between cation binding and folding
    corecore