608 research outputs found

    Obsessive-Compulsive Behavior Disappearing after Left Capsular Genu Infarction

    Get PDF
    This case report describes a 74-year-old woman with obsessive-compulsive behaviors that disappeared following a left capsular genu infarction. The patient's capsular genu infarction likely resulted in thalamocortical disconnection in the cortico-basal ganglia-thalamocortical loop, which may have caused the disappearance of her obsessive-compulsive symptoms. The fact that anterior capsulotomy has been demonstrated to be effective for treating refractory obsessive-compulsive disorder further supports this hypothesis

    Comparison of International Normalized Ratio Measurement between CoaguChek XS Plus and STA-R Coagulation Analyzers

    Get PDF
    Background. Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting. We investigated whether the prothrombin time international normalized ratio (INR) results by CoaguChek XS Plus (Roche Diagnostics GmbH, Mannheim, Germany) can be used reliably without being conļæ½rmed with the INR results by STA-R system (Diagnostica Stago S.A.S, AsniĆØres sur Seine, France). Methods. A total of 118 INR measurements by CoaguChek XS Plus and STA-R were compared using Passing/Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurements was further assessed in relation to dosing decision. Results. e correlation of INR measurements between CoaguChek XS Plus and STA-R was excellent (correlation coefficient = 0.964). e mean difference tended to increase as INR results increased and was 0.25 INR in the therapeutic range (2.0-3.0 INR). e overall agreement was fair to good (kappa = 0.679), and 21/118 (17.8%) INR measurements showed a difference in dosing decision. Conclusion. e positive bias of CoaguChek XS Plus may be obvious even in the therapeutic INR range, and dosing decision based on the CoaguChek XS Plus INR results would be different from that based on the STA-R results. e INR measurements by POCT coagulometers still need to be conļæ½rmed with the laboratory INR measurements

    Terminal fucosylation of haptoglobin in cancer-derived exosomes during cholangiocarcinoma progression

    Get PDF
    BackgroundCholangiocarcinoma (CCA) is a silent tumor with a high mortality rate due to the difficulty of early diagnosis and prediction of recurrence even after timely surgery. Serologic cancer biomarkers have been used in clinical practice, but their low specificity and sensitivity have been problematic. In this study, we aimed to identify CCA-specific glycan epitopes that can be used for diagnosis and to elucidate the mechanisms by which glycosylation is altered with tumor progression.MethodsThe serum of patients with various cancers was fractioned into membrane-bound and soluble components using serial ultracentrifugation. Lectin blotting was conducted to evaluate glycosylation. Proteins having altered glycosylation were identified using proteomic analysis and further confirmed using immunoblotting analysis. We performed HPLC, gene analysis, real-time cargo tracking, and immunohistochemistry to determine the origin of CCA glycosylation and its underlying mechanisms. Extracellular vesicles (EV) were isolated from the sera of 62 patients with CCA at different clinical stages and inflammatory conditions and used for glycan analysis to assess their clinical significance.ResultsThe results reveal that glycosylation patterns between soluble and membrane-bound fractions differ significantly even when obtained from the same donor. Notably, glycans with Ī±1-3/4 fucose and Ī²1-6GlcNAc branched structures increase specifically in membrane-bound fractions of CCA. Mechanically, it is primarily due to Ī²-haptoglobin (Ī²-Hp) originating from CCA expressing fucosyltransferase-3/4 (FUT 3/4) and N-acetylglucosaminyltransferase-V (MGAT5). Newly synthesized Ī²-Hp is loaded into EVs in early endosomes via a KFERQ-like motif and then secreted from CCA cells to induce tumor progression. In contrast, Ī²-Hp expressed by hepatocytes is secreted in a soluble form that does not affect CCA progression. Moreover, evaluation of EV glycosylation in CCA patients shows that fucosylation level of EV-Hp gradually increases with tumor progression and decreases markedly when the tumors are eliminated by surgery.ConclusionThis study suggests that terminal fucosylation of Hp in cancer-derived exosomes can be a novel glycan marker for diagnosis and prognosis of CCA. These findings highlight the potential of glycan analysis in different fractions of serum for biomarker discover for other diseases. Further research is needed to understand the role of fucosylated EVs on CCA progression

    Brain structural correlates of subjective sleepiness and insomnia symptoms in shift workers

    Get PDF
    BackgroundStudies on the brain structures of shift workers are limited; thus, this cross-sectional study aimed to compare the brain structures and the brain structural correlates of subjective sleepiness and insomnia symptoms between shift workers and non-shift workers.MethodsShift workers (nā€‰=ā€‰63) and non-shift workers (nā€‰=ā€‰58) completed questionnaires assessing subjective sleepiness and insomnia symptoms. Cortical thickness, cortical surface area, and subcortical volumes were measured by magnetic resonance imaging. The brain morphometric measures were compared between the groups, and interaction analyses using the brain morphometric measures as the dependent variable were performed to test the interactions between the study group and measures of sleep disturbance (i.e., subjective sleepiness and insomnia symptoms).ResultsNo differences in cortical thickness, cortical surface area, or subcortical volumes were detected between shift workers and non-shift workers. A single cluster in the left motor cortex showed a significant interaction between the study group and subjective sleepiness in the cortical surface area. The correlation between the left motor cortex surface area and the subjective sleepiness level was negative in shift workers and positive in non-shift workers. Significant interaction between the study group and insomnia symptoms was present for the left/right putamen volumes. The correlation between the left/right putamen volumes and insomnia symptom levels was positive in shift workers and negative in non-shift workers.ConclusionLeft motor cortex surface area and bilateral putamen volumes were unique structural correlates of subjective sleepiness and insomnia symptoms in shift workers, respectively

    A Case of Sparganosis That Presented as a Recurrent Pericardial Effusion

    Get PDF
    Sparganosis is caused by a larval tapeworm of the genus Spirometra, which commonly invades subcutaneous tissue, but less frequently invades muscle, intestines, spinal cord, and the peritoneopleural cavity. The authors managed a female patient who presented with a recurrent pericardiopleural effusion and peripheral eosinophilia. The anti-sparganum-specific IgG serum level was significantly higher than normal control levels. In this patient, sparganosis was caused by the ingestion of raw frogs in an effort to control her thyroid disease. The recurrent pericardiopleural effusion and peripheral eosinophilia were controlled by 3 consecutive doses of praziquantel (75 mg/kg/day). The patient is doing well 4 years after presentation. Sparganosis should be considered a rare, but possible cause of recurrent pericardial effusion and peripheral eosinophilia. Immunoserologic testing using enzyme linked immunosorbent assays can be helpful in diagnosing human sparganosis, especially in cases without a subcutaneous lump or mass. Praziquantel is an alternative treatment for sparganosis in surgically-unresectable cases

    Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial

    Get PDF
    BACKGROUND: There have been few randomized control trials comparing the incidence of stent fracture and primary patency among different self-expanding nitinol stents to date. The SMARTā„¢ CONTROL stent (Cordis Corp, Miami Lakes, Florida, United States) has a peak-to-valley bridge and inline interconnection, whereas the COMPLETEā„¢-SE stent (Medtronic Vascular, Santa Rosa, California, United States) crowns have been configured to minimize crown-to-crown interaction, increasing the stent's flexibility without compromising radial strength. Further, the 2011 ESC (European society of cardiology) guidelines recommend that dual antiplatelet therapy with aspirin and a thienopyridine such as clopidogrel should be administered for at least one month after infrainguinal bare metal stent implantation. Cilostazol has been reported to reduce intimal hyperplasia and subsequent repeat revascularization. To date, there has been no randomized study comparing the safety and efficacy of two different antiplatelet regimens, clopidogrel and cilostazol, following successful femoropopliteal stenting. METHODS/DESIGN: The primary purpose of our study is to examine the incidence of stent fracture and primary patency between two different major representative self-expanding nitinol stents (SMARTā„¢ CONTROL versus COMPLETEā„¢-SE) in stenotic or occlusive femoropopliteal arterial lesion. The secondary purpose is to examine whether there is any difference in efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol for one month following stent implantation in femoropopliteal lesions. This is a prospective, randomized, multicenter trial to assess the efficacy of the COMPLETEā„¢-SE versus SMARTā„¢ CONTROL stent for provisional stenting after balloon angioplasty in femoropopliteal arterial lesions. The study design is a 2x2 randomization design and a total of 346 patients will be enrolled. The primary endpoint of this study is the rate of binary restenosis in the treated segment at 12 months after intervention as determined by catheter angiography or duplex ultrasound. DISCUSSION: This trial will provide powerful insight into whether the design of the COMPLETEā„¢-SE stent is more fracture-resistant or effective in preventing restenosis compared with the SMARTā„¢ CONTROL stent. Also, it will determine the efficacy and safety of aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions. TRIAL REGISTRATION: Registered on 2 April 2012 with the National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier# NCT01570803)

    Establishment of particulate matter-induced lung injury model in mouse

    Get PDF
    Background Particulate matter (PM) is one of the principal causes of human respiratory disabilities resulting from air pollution. Animal models have been applied to discover preventive and therapeutic drugs for lung diseases caused by PM. However, the induced severity of lung injury in animal models using PM varies from study to study due to disparities in the preparation of PM, and the route and number of PM administrations. In this study, we established an in vivo model to evaluate PM-induced lung injury in mice. Results PM dispersion was prepared using SRM2975. Reactive oxygen species were increased in MLE 12 cells exposed to this PM dispersion. In vivo studies were conducted in the PM single challenge model, PM multiple challenge model, and PM challenge with ovalbumin-induced asthma using the PM dispersion. No histopathological changes were observed in lung tissues after a single injection of PM, whereas mild to moderate lung inflammation was obtained in the lungs of mice exposed to PM three times. However, fibrotic changes were barely seen, even though transmission electron microscopy (TEM) studies revealed the presence of PM particles in the alveolar macrophages and alveolar capillaries. In the OVA-PM model, peribronchial inflammation and mucous hypersecretion were more severe in the OVA+PM group than the OVA group. Serum IgE levels tended to increase in OVA+PM group than in OVA group. Conclusions In this study, we established a PM-induced lung injury model to examine the lung damage induced by PM. Based on our results, repeated exposures of PM are necessary to induce lung inflammation by PM alone. PM challenge, in the presence of underlying diseases such as asthma, can also be an appropriate model for studying the health effect of PM.This research was supported by Univera Co., Ltd., as one of the CAP projects and Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2020R1A6A1A03043708)
    • ā€¦
    corecore