18 research outputs found

    Ocular hypotensive effect of the novel EP3/FP agonist ONO-9054 versus Xalatan: results of a 28-day, double-masked, randomised study

    Get PDF
    Background/aims ONO-9054 is being developed for the reduction of intraocular pressure (IOP) in patients with ocular hypertension (OHT) and open-angle glaucoma (OAG). This study compared the novel dual EP3/FP agonist ONO-9054 with the FP agonist Xalatan. Methods Adults (n=123) with bilateral mild/moderate OAG or OHT, with unmedicated IOP of ≥24 mm Hg at 8:00 hours, ≥21 mm Hg at 10:00 hours and ≤36 mm Hg, were randomised 1:1 to receive ONO-9054 (0.003%, 30 μg/mL) or Xalatan (0.005%, 50 μg/mL) once daily for 28 days. Results Day 29 mean diurnal IOP was −7.2 mm Hg for ONO-9054 vs −6.6 mm Hg for Xalatan. At 08:00 hours, the IOPs were comparable, and at all later time points the decrease in IOP was greater for ONO-9054. On day 29, the odds of a mean IOP reduction of ≤−25%, ≤−30% and ≤−35% for ONO-9054 were 2.39, 2.37 and 4.85 times more, respectively, than the odds for Xalatan (p<0.05, post hoc analyses). The percentage of subjects achieving target IOPs on day 29 (≤17, ≤16 and ≤15 mm Hg) was greater for ONO-9054 than for Xalatan; the odds of achieving an IOP ≤15 mm Hg for ONO-9054 were 2.4 times more than the odds for Xalatan (p<0.01, post hoc analysis). Conclusions Subjects randomised to receive ONO-9054 were more likely to achieve a greater per cent reduction in IOP and were more likely to achieve target IOPs than those receiving Xalatan. The effects of ONO-9054 in reducing IOP appear to persist longer than those of Xalatan

    New devices in glaucoma

    Get PDF
    Glaucoma remains a leading cause of blindness globally. Minimally invasive treatment techniques are rapidly expanding the availability of therapeutic options for glaucoma. These include devices aimed at enhancing outflow through the subconjunctival space, Schlemm\u27s canal, and suprachoroidal space, sustained-release drug delivery devices, and extraocular devices aiming to reduce glaucomatous progression through other novel means. In this review, we provide an overview of several novel devices either newly available or in development for the medical and surgical management of glaucoma. Further studies are required to determine the long-term efficacy of these devices and how they will integrate into the current landscape of glaucoma management

    Phase 3, Randomized, 20-Month Study of the Efficacy and Safety of Bimatoprost Implant in Patients with Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 2)

    Get PDF
    Objective- To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods- This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG or OHT and an open iridocorneal angle inferiorly in the study eye. Study eyes were administered 10 or 15 µg bimatoprost implant on day 1, week 16, and week 32, or twice-daily topical timolol maleate 0.5%. Primary endpoints were IOP and IOP change from baseline through week 12. Safety measures included treatment-emergent adverse events (TEAEs) and corneal endothelial cell density (CECD). Results- Both 10 and 15 µg bimatoprost implant met the primary endpoint of noninferiority to timolol in IOP lowering through 12 weeks. Mean IOP reductions from baseline ranged from 6.2–7.4, 6.5–7.8, and 6.1–6.7 mmHg through week 12 in the 10 µg implant, 15 µg implant, and timolol groups, respectively. IOP lowering was similar after the second and third implant administrations. Probabilities of requiring no IOP-lowering treatment for 1 year after the third administration were 77.5% (10 µg implant) and 79.0% (15 µg implant). The most common TEAE was conjunctival hyperemia, typically temporally associated with the administration procedure. Corneal TEAEs of interest (primarily corneal endothelial cell loss, corneal edema, and corneal touch) were more frequent with the 15 than the 10 µg implant and generally were reported after repeated administrations. Loss in mean CECD from baseline to month 20 was ~ 5% in 10 µg implant-treated eyes and ~ 1% in topical timolol-treated eyes. Visual field progression (change in the mean deviation from baseline) was reduced in the 10 µg implant group compared with the timolol group. Conclusions- The results corroborated the previous phase 3 study of the bimatoprost implant. The bimatoprost implant met the primary endpoint and effectively lowered IOP. The majority of patients required no additional treatment for 12 months after the third administration. The benefit-risk assessment favored the 10 over the 15 µg implant. Studies evaluating other administration regimens with reduced risk of corneal events are ongoing. The bimatoprost implant has the potential to improve adherence and reduce treatment burden in glaucoma

    Cost and yield considerations when expanding recruitment for genetic studies: the primary open-angle African American glaucoma genetics study

    No full text
    Abstract Background African Americans have been historically under-represented in genetic studies. More research is needed on effective recruitment strategies for this population, especially on approaches that supplement traditional clinic enrollment. This study evaluates the cost and efficacy of four supplemental recruitment methods employed by the Primary Open-Angle African American Glaucoma Genetics (POAAGG) study. Methods After enrolling 2304 patients from University of Pennsylvania ophthalmology clinics, the POAAGG study implemented four new recruitment methods to supplement clinic enrollment. These methods included: 1) outreach in the local community, 2) in-house screening of community members (“in-reach”), 3) expansion to two external sites, and 4) sampling of the Penn Medicine Biobank. The cost per subject was calculated for each method and enrollment among cases, controls, and suspects was reported. Results The biobank offered the lowest cost (5/subject)andhighestenrollmentyield(n = 2073)ofthefourmethods,butprovidedveryfewglaucomacases(n = 31).Externalsitesprovided885/subject) and highest enrollment yield (n = 2073) of the four methods, but provided very few glaucoma cases (n = 31). External sites provided 88% of cases recruited from the four methods (n = 388; 85/subject), but case enrollment at these sites declined over the next 9 months as the pool of eligible subjects was depleted. Outreach and in-reach screenings of community members were very high cost for low return on enrollment (569/subjectfor102subjectsand569/subject for 102 subjects and 606/subject for 45 subjects, respectively). Conclusions The biobank offered the most cost-effective method for control enrollment, while expansion to external sites was necessary to recruit richly phenotyped cases. These recruitment methods helped the POAAGG study to exceed enrollment of the discovery cohort (n = 5500) 6 months in advance of the predicated deadline and could be adopted by other large genetic studies seeking to supplement clinic enrollment

    Risk factors for structural and functional progression of primary open-angle glaucoma in an African ancestry cohort

    No full text
    Background/aims To investigate the rates of structural and functional progression of primary open-angle glaucoma in an African ancestry cohort and identify risk factors for progression.Methods This retrospective study included 1424 eyes from glaucoma cases in the Primary Open-Angle African American Glaucoma Genetics cohort, with ≥2 visits for retinal nerve fibre layer (RNFL) thickness and mean deviation (MD) measurements over ≥6-month follow-up. The rates of structural progression (change in RNFL thickness/year) and functional progression (change in MD/year) were calculated from linear mixed effects models, accounting for intereye correlation and longitudinal correlation. Eyes were categorised as slow, moderate or fast progressors. Risk factors for progression rates were assessed using univariable and multivariable regression models.Results The median (interquartile) rates of progression were −1.60 (−2.05 to –1.15) µm/year for RNFL thickness and −0.40 (−0.44 to –0.34) decibels/year for MD. Eyes were categorised as slow (structural: 19%, functional: 88%), moderate (structural: 54%, functional: 11%) and fast (structural: 27%, functional: 1%) progressors. In multivariable analysis, faster RNFL progression was independently associated with thicker baseline RNFL (p&lt;0.0001), lower baseline MD (p=0.003) and beta peripapillary atrophy (p=0.03). Faster MD progression was independently associated with higher baseline MD (p&lt;0.0001), larger cup-to-disc ratios (p=0.02) and lower body mass index (p=0.0004).Conclusion The median rates of structural and functional progression in this African ancestry cohort were faster than the rates reported from previously published studies in other ethnic groups. Higher baseline RNFL thickness and MD values were associated with faster progression rates. Results highlight the importance of monitoring structural and functional glaucoma progression to provide timely treatment in early disease

    Mitochondrial Sequence Variation in African-American Primary Open-Angle Glaucoma Patients

    Get PDF
    <div><p>Primary open-angle glaucoma (POAG) is a major cause of blindness and results from irreversible retinal ganglion cell damage and optic nerve degeneration. In the United States, POAG is most prevalent in African-Americans. Mitochondrial genetics and dysfunction have been implicated in POAG, and potentially pathogenic sequence variations, in particular novel transversional base substitutions, are reportedly common in mitochondrial genomes (mtDNA) from POAG patient blood. The purpose of this study was to ascertain the spectrum of sequence variation in mtDNA from African-American POAG patients and determine whether novel nonsynonymous, transversional or other potentially pathogenic sequence variations are observed more commonly in POAG cases than controls. mtDNA from African-American POAG cases (n = 22) and age-matched controls (n = 22) was analyzed by deep sequencing of a single 16,487 base pair PCR amplicon by Ion Torrent, and candidate novel variants were validated by Sanger sequencing. Sequence variants were classified and interpreted using the MITOMAP compendium of polymorphisms. 99.8% of the observed variations had been previously reported. The ratio of novel variants to POAG cases was 7-fold lower than a prior estimate. Novel mtDNA variants were present in 3 of 22 cases, novel nonsynonymous changes in 1 of 22 cases and novel transversions in 0 of 22 cases; these proportions are significantly lower (p<.0005, p<.0004, p<.0001) than estimated previously for POAG, and did not differ significantly from controls. Although it is possible that mitochondrial genetics play a role in African-Americans’ high susceptibility to POAG, it is unlikely that any mitochondrial respiratory dysfunction is due to an abnormally high incidence of novel mutations that can be detected in mtDNA from peripheral blood.</p> </div

    Heteroplasmic variants.

    No full text
    <p>Two examples of heteroplasmic variants that were detected on the basis of mixed Ion Torrent reads (top) and confirmed by CE, Sanger sequencing (bottom). One was from a POAG case (panel A) and one was from a control (panel B).</p
    corecore