13 research outputs found

    Minimum Clinically Important Differences in Oswestry Disability Index Domains and Their Impact on Adult Spinal Deformity Surgery

    Get PDF
    Study Design Retrospective study. Purpose To calculate the minimum clinically important difference (MCID) for total and individual domains of the Oswestry Disability Index (ODI) and assess score distribution and changes over time in surgically treated adult spinal deformity (ASD) patients. Overview of Literature Despite the common use of ODI for assessing ASD, there are no robust studies defining MCID values for this index. Methods This study included 240 consecutive ASD patients with a minimum of 2 years of follow-up. We calculated MCID values for total and individual ODI domains using all or part of the Scoliosis Research Society-22R questionnaire as anchors. Using current MCID values, we measured the acquisition rates in patients who acquired MCID at follow-up in both total and individual ODI domains. Differences in pathology, age, and locations of the upper and lower instrumented vertebrae were analyzed. Results MCID of the total ODI score was 11%, with an area under the curve of 0.737. Each domain ranged from 0 to 2, with 1 being the most common value. In the pain and standing domains, >60% of the patients acquired MCID, although acquisition rates of the personal care, lifting, sleep, and sexual activity domains were relatively low (20%–35%). Patients with MCID had more radiographic improvement in lumbar lordosis, sagittal vertical axis, and T1 pelvic angle than those without MCID (p<0.05). Conclusions To our knowledge, this is the first study to describe MCID of ODI (11%) after ASD surgery. In the pain and standing domains, most patients acquired MCID although the rates of acquisition of MCID in the personal care, lifting, sleep, and sexual activity domains were low. Spine surgeons should counsel their patients regarding the benefits and setbacks of ASD surgery

    13Th International Conference On Conservative Management Of Spinal Deformities And First Joint Meeting Of The International Research Society On Spinal Deformities And The Society On Scoliosis Orthopaedic And Rehabilitation Treatment – Sosort-Irssd 2016 Meeting

    No full text
    PubMe

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics
    corecore