45 research outputs found

    Saphenous vein harvest with the Mayo extraluminal dissector: Is endothelial function preserved?

    Get PDF

    Preparo da veia safena na cirurgia de revascularização miocárdica: uma nova técnica -no touch- que mantém a parede da veia íntegra e proporciona uma alta perviabilidade imediata

    Get PDF
    BACKGROUND: The technique of harvesting the saphenous vein (SV) for coronary artery bypass grafting (CABG) influences the fate of vein grafts. A new no touch (NT) technique of SV preparation was developed where the vein is harvested with a pedicle of surrounding tissue, which protects the vein from spasms therefore obviating the need for distension. METHOD: A prospective randomized study in 156 patients who underwent CABG was performed comparing three SV harvesting techniques. The techniques were conventional (c) (adventitial stripping of the vein, manual distention and storing in saline solution); Intermediate (I) (after adventitial stripping, the vein was left in situ, covered with a papaverine-soaked compress, and stored in heparinized blood); and no touch (SV dissected with its surrounding tissue was left in situ, covered with a saline-soaked compress and stored in heparinized blood). A morphological study of the endothelium was preformed using scanning electronic microscopy and an angiographic assessment of the vein graft patency was performed at 18 months mean follow-up time. Also an immunohistochemistry assessment was performed to identify the enzyme, nitric oxide synthase (NOS) in the vein wall. RESULTS: The preservation of the endothelial cell integrity was greater with the no touch technique than with the other procedures. At angiographic follow up, the patency for NT was 95.4%, 88.9% for grafts in group C and 86.2% for grafts in group I. The immunohistochemistry assessment revealed NOS in all three layers of the vein wall that was prepared by the no touch technique. However, a great reduction of this enzyme in veins treated by the conventional technique was observed. CONCLUSION: The endothelial integrity and NOS activity were better preserved when using the no touch technique for vein graft harvesting. The vasorelaxation and thrombo-resistant activities of nitric oxide (NO) may be responsible for the reduced of vasospasms and improved patency rate. Furthermore, the mechanical properties provided by the cushion of surrounding tissue in graft harvested by NT technique may contribute to the observed high patency rate.OBJETIVO: O objetivo deste trabalho é apresentar uma nova técnica no touch de preparo da veia safena e sua importância clínica. Esta nova técnica consiste na retirada da veia safena do seu leito, juntamente com um pedículo de tecido adiposo, protegendo a veia contra espasmos e, conseqüentemente, da necessidade de distendê-la durante a operação. MÉTODO: O estudo foi realizado em dois tempos: 1) Inicialmente, foi realizado um estudo prospectivo e randomizado, envolvendo 156 pacientes que foram submetidos à operação de revascularização miocárdica. Neste estudo nós comparamos a técnica no touch (NT) com duas outras: a convencional (C) e a intermediária (I). Foi feita uma avaliação detalhada da morfologia endotelial, utilizando a microscopia eletrônica, enquanto que a perviabilidade das pontes foi determinada com um exame angiográfico executado num período médio de 18 meses após a operação. 2) Finalmente, a enzima óxido nítrico síntase (NOS) foi identificada com ajuda do estudo imunohistoquímico e também pela localização auto-radiográfica de (3H)-L- Nitro-Arginina (NOARG). RESULTADOS: A avaliação morfológica mostrou integridade endotelial de 97% nas veias que foram tratadas pela técnica NT; enquanto quase metade da superfície endotelial das veias tratadas pelas outras duas técnicas exibiu ausência de células endoteliais. O exame angiográfico revelou perviabilidade de 95,4% para as pontes do grupo NT, 88,9% para as pontes do grupo (C) e 86,2% para as pontes do grupo (I). O estudo imunohistoquímico revelou a presença de NOS nas três camadas que compõem a parede da veia quando, as mesmas, foram tratadas pela técnica NT. Por outro lado, foi observada uma elevada redução desta enzima nas veias que foram tratadas pela técnica (C). A análise auto-radiográfica confirmou os resultados imunohistoquímicos. CONCLUSÃO: A integridade endotelial e a atividade da enzima óxido nítrico síntase foram melhor mantidas com o uso da técnica NT no preparo da veia safena. A atividade vasodilatadora e bloqueadora da agregação plaquetária causada pelo óxido nítrico (NO) pode ser a responsável pela proteção da veia contra o espasmo, como também pela alta perviabilidade imediata da mesma. Além disso, as propriedades mecânicas providas pelo tecido gorduroso em volta da veia, contribuíram para o melhor resultado desta nova técnica.University Hospital of Örebro Cardiothoracic Surgery DivisionUniversity Hospital Royal Free College Medical School Molecular Pathology and Biochemical DivisionHospital do Servidor Público EstadualUNIFESP Paulista Medical School Cardiothoracic Surgery DivisionHospital Oswaldo Cruz Cardiothoracic Surgery DivisionUNIFESP, Paulista Medical School Cardiothoracic Surgery DivisionSciEL

    Formation of Long-Lived Color Centers for Broadband Visible Light Emission in Low-Dimensional Layered Perovskites.

    Get PDF
    We investigate the origin of the broadband visible emission in layered hybrid lead-halide perovskites and its connection with structural and photophysical properties. We study ⟨001⟩ oriented thin films of hexylammonium (HA) lead iodide, (C6H16N)2PbI4, and dodecylammonium (DA) lead iodide, (C12H28N)2PbI4, by combining first-principles simulations with time-resolved photoluminescence, steady-state absorption and X-ray diffraction measurements on cooling from 300 to 4 K. Ultrafast transient absorption and photoluminescence measurements are used to track the formation and recombination of emissive states. In addition to the excitonic photoluminescence near the absorption edge, we find a red-shifted, broadband (full-width at half-maximum of about 0.4 eV), emission band below 200 K, similar to emission from ⟨110⟩ oriented bromide 2D perovskites at room temperature. The lifetime of this sub-band-gap emission exceeds that of the excitonic transition by orders of magnitude. We use X-ray diffraction measurements to study the changes in crystal lattice with temperature. We report changes in the octahedral tilt and lattice spacing in both materials, together with a phase change around 200 K in DA2PbI4. DFT simulations of the HA2PbI4 crystal structure indicate that the low-energy emission is due to interstitial iodide and related Frenkel defects. Our results demonstrate that white-light emission is not limited to ⟨110⟩ oriented bromide 2D perovskites but a general property of this class of system, and highlight the importance of defect control for the formation of low-energy emissive sites, which can provide a pathway to design tailored white-light emitters

    Endothelin-1 as a neuropeptide: neurotransmitter or neurovascular effects?

    Get PDF
    Endothelin-1 (ET-1) is an endothelium-derived peptide that also possesses potent mitogenic activity. There is also a suggestion the ET-1 is a neuropeptide, based mainly on its histological identification in both the central and peripheral nervous system in a number of species, including man. A neuropeptide role for ET-1 is supported by studies showing a variety of effects caused following its administration into different regions of the brain and by application to peripheral nerves. In addition there are studies proposing that ET-1 is implicated in a number of neural circuits where its transmitter affects range from a role in pain and temperature control to its action on the hypothalamo-neurosecretory system. While the effect of ET-1 on nerve tissue is beyond doubt, its action on nerve blood flow is often ignored. Here, we review data generated in a number of species and using a variety of experimental models. Studies range from those showing the distribution of ET-1 and its receptors in nerve tissue to those describing numerous neurally-mediated effects of ET-1

    Sulforaphane Causes Epigenetic Repression of hTERT Expression in Human Breast Cancer Cell Lines

    Get PDF
    Sulforaphane (SFN), an isothiocyanate found in cruciferous vegetables, is a common dietary component that has histone deacetylase inhibition activity and exciting potential in cancer prevention. The mechanisms by which SFN imparts its chemopreventive properties are of considerable interest and little is known of its preventive potential for breast cancer. expression facilitated the induction of cellular apoptosis in human breast cancer cells.Collectively, our results provide novel insights into SFN-mediated epigenetic down-regulation of telomerase in breast cancer prevention and may open new avenues for approaches to SFN-mediated cancer prevention

    Towards Endoscopic No-Touch Saphenous Vein Graft Harvesting in Coronary Bypass Surgery

    No full text
    The saphenous vein is the most used conduit for coronary artery bypass surgery. However, the patency rate of this graft is inferior to the internal thoracic artery patency rate, which is the gold standard. Using the conventional technique, the saphenous vein is harvested via a large open incision and excised in such a way that causes both vascular damage and wound healing complications. Consequently, vein graft patency and surgical site infection may be compromised. Graft patency is markedly improved when the saphenous vein is harvested atraumatically with minimal damage and with surrounding cushion of perivascular fat intact. However, despite the improved graft performance, wound healing complications and infection remain a problem. Although wound healing complication is reduced when using endoscopic vein harvesting, there may be a negative impact on graft performance. This is due to vascular damage associated with application of forces to the vein that are usually avoided in open vein harvesting, including traction, adventitial stripping, and venous compression. There is evidence to suggest that improved patency of endoscopically harvested saphenous veins is associated with the surgeon's experience of the technique. Recently, endoscopic methods of harvesting have been described where the saphenous vein is removed intact and with minimal vascular damage caused. In addition, wound healing complications, infection, and scarring are reduced. While the effect of these techniques on vein graft patency have yet to be reported, the ability to obtain a superior graft with reduced wound complications will be of great benefit to patients undergoing coronary revascularization procedures
    corecore