578 research outputs found

    Minimal Extension of the Standard Model Scalar Sector

    Get PDF
    The minimal extension of the scalar sector of the standard model contains an additional real scalar field with no gauge quantum numbers. Such a field does not couple to the quarks and leptons directly but rather through its mixing with the standard model Higgs field. We examine the phenomenology of this model focusing on the region of parameter space where the new scalar particle is significantly lighter than the usual Higgs scalar and has small mixing with it. In this region of parameter space most of the properties of the additional scalar particle are independent of the details of the scalar potential. Furthermore the properties of the scalar that is mostly the standard model Higgs can be drastically modified since its dominant branching ratio may be to a pair of the new lighter scalars.Comment: 4 pages, 2 figure

    Disrupted Maturation of the Microbiota and Metabolome among Extremely Preterm Infants with Postnatal Growth Failure

    Get PDF
    Growth failure during infancy is a major global problem that has adverse effects on long-term health and neurodevelopment. Preterm infants are disproportionately affected by growth failure and its effects. Herein we found that extremely preterm infants with postnatal growth failure have disrupted maturation of the intestinal microbiota, characterized by persistently low diversity, dominance of pathogenic bacteria within the Enterobacteriaceae family, and a paucity of strictly anaerobic taxa including Veillonella relative to infants with appropriate postnatal growth. Metabolomic profiling of infants with growth failure demonstrated elevated serum acylcarnitines, fatty acids, and other byproducts of lipolysis and fatty acid oxidation. Machine learning algorithms for normal maturation of the microbiota and metabolome among infants with appropriate growth revealed a pattern of delayed maturation of the microbiota and metabolome among infants with growth failure. Collectively, we identified novel microbial and metabolic features of growth failure in preterm infants and potentially modifiable targets for intervention

    Scintigraphic assessment of sympathetic innervation after transmural versus nontransmural myocardial infarction

    Get PDF
    To evaluate the feasibility of detecting denervated myocardium in the infarcted canine heart, the distribution of sympathetic nerve endings using 1–123 metaiodobenzylguanidine (MIBG) was compared with the distribution of perfusion using thallium-201, with the aid of color-coded computer functional map in 16 dogs. Twelve dogs underwent myocardial infarction by injection of vinyl latex into the left anterior descending coronary artery (transmural myocardial infarction, n = 6), or ligation of the left anterior descending coronary artery (nontransmural myocardial infarction, n = 6). Four dogs served as sham-operated controls. Image patterns were compared with tissue norepinephrine content and with histofluorescence microscopic findings in biopsy specimens.Hearts with transmural infarction showed zones of absent MIBG and thallium, indicating scar. Adjacent and distal regions showed reduced MIBG but normal thallium uptake, indicating viable but denervated myocardium. Denervation distal to infarction was confirmed by reduced norepinephrine content and absence of nerve fluorescence. Nontransmural myocardial infarction showed zones of wall thinning with decreased thallium uptake and a greater reduction or absence of MIBG localized to the region of the infarct, with minimal extension of denervation beyond the infarct. Norepinephrine content was significantly reduced in the infarct zone, and nerve fluorescence was absent.These findings suggest that 1) MIBG imaging can detect viable and perfused but denervated myocardium after infarction; and 2) as opposed to the distal denervation produced by transmural infarction, nontransmural infarction may lead to regional ischemic damage of sympathetic nerves, but may spare subepicardial nerve trunks that course through the region of infarction to provide a source of innervation to distal areas of myocardium

    Insights into Self-Poisoning during Catalytic Hydrogenation on Platinum Surfaces Using ATR-IR Spectroelectrochemistry

    Get PDF
    Attenuated total reflection infrared (ATR-IR) spectroscopy has been combined with electrochemical methods to investigate molecular decomposition and self-poisoning processes on platinum surfaces under the conditions of catalytic hydrogenation. In aqueous 0.1 M H<sub>2</sub>SO<sub>4</sub> the α-keto ester ethyl pyruvate (EP) is found to decompose on polycrystalline platinum electrodes to yield surface-adsorbed CO, but the observed behavior is highly dependent on the electrode potential, a parameter intimately linked to the surface-adsorbed hydrogen coverage. In the potential range −0.2 to −0.4 V (vs mercury/mercurous sulfate electrode) where the hydrogen coverage is negligible, CO is readily produced at the platinum surface along with other molecular fragments but the decomposition process becomes inhibited at high EP solution concentrations. At −0.5 V only very low coverages of CO are observed due to competing hydrogen adsorption at Pt(100) step sites which most favor EP decomposition. At more negative potentials, during the onset of catalytic EP hydrogenation, CO is generated rapidly but other intermediates or products are not observed in the ATR-IR spectra. Together these observations suggest two different mechanisms of EP decomposition, the first occurring directly upon EP adsorption and the second occurring after a single hydrogen atom transfer under hydrogen rich conditions. This ability to control substrate decomposition by tuning the surface hydrogen coverage may be used as a potential route to mitigating catalyst poisoning and deactivation during hydrogenation reactions

    Breathomics—exhaled volatile organic compound analysis to detect hepatic encephalopathy : a pilot study

    Get PDF
    he current diagnostic challenge with diagnosing hepatic encephalopathy (HE) is identifying those with minimal HE as opposed to the more clinically apparent covert/overt HE. Rifaximin, is an effective therapy but earlier identification and treatment of HE could prevent liver disease progression and hospitalization. Our pilot study aimed to analyse breath samples of patients with different HE grades, and controls, using a portable electronic (e) nose. 42 patients were enrolled; 22 with HE and 20 controls. Bedside breath samples were captured and analysed using an uvFAIMS machine (portable e-nose). West Haven criteria applied and MELD scores calculated. We classify HE patients from controls with a sensitivity and specificity of 0.88 (0.73-0.95) and 0.68 (0.51-0.81) respectively, AUROC 0.84 (0.75-0.93). Minimal HE was distinguishable from covert/overt HE with sensitivity of 0.79 and specificity of 0.5, AUROC 0.71 (0.57-0.84). This pilot study has highlighted the potential of breathomics to identify VOCs signatures in HE patients for diagnostic purposes. Importantly this was performed utilizing a non-invasive, portable bedside device and holds potential for future early HE diagnosis

    Coherent optical wavelength conversion via cavity-optomechanics

    Get PDF
    We theoretically propose and experimentally demonstrate coherent wavelength conversion of optical photons using photon-phonon translation in a cavity-optomechanical system. For an engineered silicon optomechanical crystal nanocavity supporting a 4 GHz localized phonon mode, optical signals in a 1.5 MHz bandwidth are coherently converted over a 11.2 THz frequency span between one cavity mode at wavelength 1460 nm and a second cavity mode at 1545 nm with a 93% internal (2% external) peak efficiency. The thermal and quantum limiting noise involved in the conversion process is also analyzed, and in terms of an equivalent photon number signal level are found to correspond to an internal noise level of only 6 and 4x10-3 quanta, respectively.Comment: 11 pages, 7 figures, appendi

    Vacuum Stability, Perturbativity, and Scalar Singlet Dark Matter

    Get PDF
    We analyze the one-loop vacuum stability and perturbativity bounds on a singlet extension of the Standard Model (SM) scalar sector containing a scalar dark matter candidate. We show that the presence of the singlet-doublet quartic interaction relaxes the vacuum stability lower bound on the SM Higgs mass as a function of the cutoff and lowers the corresponding upper bound based on perturbativity considerations. We also find that vacuum stability requirements may place a lower bound on the singlet dark matter mass for given singlet quartic self coupling, leading to restrictions on the parameter space consistent with the observed relic density. We argue that discovery of a light singlet scalar dark matter particle could provide indirect information on the singlet quartic self-coupling.Comment: 25 pages, 10 figures; v2 - fixed minor typos; v3 - added to text discussions of other references, changed coloring of figures for easier black and white viewin

    Using H-alpha Morphology and Surface Brightness Fluctuations to Age-Date Star Clusters in M83

    Get PDF
    We use new WFC3 observations of the nearby grand design spiral galaxy M83 to develop two independent methods for estimating the ages of young star clusters. The first method uses the physical extent and morphology of Halpha emission to estimate the ages of clusters younger than tau ~10 Myr. It is based on the simple premise that the gas in very young (tau < few Myr) clusters is largely coincident with the cluster stars, is in a small, ring-like structure surrounding the stars in slightly older clusters (e.g., tau ~5 Myr), and is in a larger ring-like bubble for still older clusters (i.e., ~5-10 Myr). The second method is based on an observed relation between pixel-to-pixel flux variations within clusters and their ages. This method relies on the fact that the brightest individual stars in a cluster are most prominent at ages around 10 Myr, and fall below the detection limit (i.e., M_V < -3.5) for ages older than about 100 Myr. These two methods are the basis for a new morphological classification system which can be used to estimate the ages of star clusters based on their appearance. We compare previous age estimates of clusters in M83 determined from fitting UBVI Halpha measurements using predictions from stellar evolutionary models with our new morphological categories and find good agreement at the ~95% level. The scatter within categories is ~0.1 dex in log tau for young clusters (10 Myr) clusters. A by-product of this study is the identification of 22 "single-star" HII regions in M83, with central stars having ages ~4 Myr.Comment: 33 pages, 10 figures, 3 tables; published in March Ap

    Epigenetic and transcriptome profiling identifies a population of visceral adipose-derived progenitor cells with potential to differentiate into an endocrine pancreatic lineage

    Get PDF
    Type 1 diabetes (T1D) is characterized by the loss of insulin-producing ÎČ-cells in the pancreas. T1D can be treated using cadaveric islet transplantation, but this therapy is severely limited by a lack of pancreas donors. To develop an alternative cell source for transplantation therapy, we carried out the epigenetic characterization in nine different adult mouse tissues and identified visceral adipose-derived progenitors as a candidate cell population. Chromatin conformation, assessed using chromatin immunoprecipitation (ChIP) sequencing and validated by ChIP-polymerase chain reaction (PCR) at key endocrine pancreatic gene promoters, revealed similarities between visceral fat and endocrine pancreas. Multiple techniques involving quantitative PCR, in-situ PCR, confocal microscopy, and flow cytometry confirmed the presence of measurable (2–1000-fold over detectable limits) pancreatic gene transcripts and mesenchymal progenitor cell markers (CD73, CD90 and CD105; >98%) in visceral adipose tissue-derived mesenchymal cells (AMCs). The differentiation potential of AMCs was explored in transgenic reporter mice expressing green fluorescent protein (GFP) under the regulation of the Pdx1 (pancreatic and duodenal homeobox-1) gene promoter. GFP expression was measured as an index of Pdx1 promoter activity to optimize culture conditions for endocrine pancreatic differentiation. Differentiated AMCs demonstrated their capacity to induce pancreatic endocrine genes as evidenced by increased GFP expression and validated using TaqMan real-time PCR (at least 2–200-fold relative to undifferentiated AMCs). Human AMCs differentiated using optimized protocols continued to produce insulin following transplantation in NOD/SCID mice. Our studies provide a systematic analysis of potential islet progenitor populations using genome-wide profiling studies and characterize visceral adipose-derived cells for replacement therapy in diabetes

    Exploring wearable sensors as an alternative to marker-based motion capture in the pitching delivery

    Get PDF
    Background Improvements in data processing, increased understanding of the biomechanical background behind kinetics and kinematics, and technological advancements in inertial measurement unit (IMU) sensors have enabled high precision in the measurement of joint angles and acceleration on human subjects. This has resulted in new devices that reportedly measure joint angles, arm speed, and stresses to the pitching arms of baseball players. This study seeks to validate one such sensor, the MotusBASEBALL unit, with a marker-based motion capture laboratory. Hypothesis We hypothesize that the joint angle measurements (“arm slot” and “shoulder rotation”) of the MotusBASEBALL device will hold a statistically significant level of reliability and accuracy, but that the “arm speed” and “stress” metrics will not be accurate due to limitations in IMU technology. Methods A total of 10 healthy subjects threw five to seven fastballs followed by five to seven breaking pitches (slider or curveball) in the motion capture lab. Subjects wore retroreflective markers and the MotusBASEBALL sensor simultaneously. Results It was found that the arm slot (R = 0.975, P < 0.001), shoulder rotation (R = 0.749, P < 0.001), and stress (R = 0.667, P = 0.001 when compared to elbow torque; R = 0.653, P = 0.002 when compared to shoulder torque) measurements were all significantly correlated with the results from the motion capture lab. Arm speed showed significant correlations to shoulder internal rotation speed (R = 0.668, P = 0.001) and shoulder velocity magnitude (R = 0.659, P = 0.002). For the entire sample, arm slot and shoulder rotation measurements were on a similar scale, or within 5–15% in absolute value, of magnitude to measurements from the motion capture test, averaging eight degrees less (12.9% relative differences) and nine degrees (5.4%) less, respectively. Arm speed had a much larger difference, averaging 3,745 deg/s (80.2%) lower than shoulder internal rotation velocity, and 3,891 deg/s (80.8%) less than the shoulder velocity magnitude. The stress metric was found to be 41 Newton meter (Nm; 38.7%) less when compared to elbow torque, and 42 Nm (39.3%) less when compared to shoulder torque. Despite the differences in magnitude, the correlations were extremely strong, indicating that the MotusBASEBALL sensor had high reliability for casual use. Conclusion This study attempts to validate the use of the MotusBASEBALL for future studies that look at the arm slot, shoulder rotation, arm speed, and stress measurements from the MotusBASEBALL sensor. Excepting elbow extension velocity, all metrics from the MotusBASEBALL unit showed significant correlations to their corresponding metrics from motion capture and while some magnitudes differ substantially and therefore fall short in validity, the link between the metrics is strong enough to indicate reliable casual use. Further research should be done to further investigate the validity and reliability of the arm speed metric
    • 

    corecore