154 research outputs found

    Reply

    Get PDF

    Comparative Effectiveness of Drug-Eluting Versus Bare-Metal Stents in Elderly Patients Undergoing Revascularization of Chronic Total Coronary Occlusions Results From the National Cardiovascular Data Registry, 2005–2008

    Get PDF
    ObjectivesThis study sought to investigate the long-term effectiveness of drug-eluting stents (DES) versus bare-metal stents (BMS).BackgroundImproved recanalization techniques have increased interest in percutaneous coronary intervention (PCI) for chronic total coronary occlusion (CTO). The long-term effectiveness of DES and BMS is not known.MethodsWe used data from 10,261 stable patients age ≥65 years at 889 U.S. hospitals who underwent CTO PCI from January 1, 2005, to December 31, 2008, in the NCDR (National Cardiovascular Data Registry) CathPCI Registry with linked Medicare inpatient claims for follow-up. Patient and procedural characteristics, and 30-month death, myocardial infarction, revascularization, and hospitalization for bleeding were evaluated by stent type. Outcomes following stenting were adjusted and compared using propensity score matching.ResultsDES were used for CTO PCI in 8,218 (80%) and BMS in 2,043 (20%). DES patients were younger (74.0 vs. 75.5 years, p < 0.001), had longer lesions (18.8 vs. 16.5 mm, p < 0.001), received more stents (≥2 stents in 45.7% vs. 37.9%, p < 0.001), and underwent multivessel PCI (18.9% vs. 15.1%, p < 0.001). DES implantation was associated with a lower hazard of mortality (hazard ratio [HR]: = 0.72, 95% confidence interval [CI]: 0.60 to 0.86, p < 0.001), a similar hazard for myocardial infarction (HR: 0.85, 95% CI: 0.61 to 1.19, p = 0.35), and subsequent revascularization (HR: 0.94, 95% CI: 0.79 to 1.12, p = 0.48), including PCI (HR: 0.98, 95% CI: 0.83 to 1.19, p = 0.87) and coronary artery bypass grafting (HR: 0.71, 95% CI: 0.46 to 1.10, p = 0.12). Hospitalization for bleeding was also similar for DES versus BMS (HR: 0.92; 95% CI: 0.61 to 1.39, p = 0.70).ConclusionsCompared with BMS, DES use in stable patients undergoing CTO PCI was associated with lower mortality, as well as similar myocardial infarction and repeat revascularization rates without an increase in subsequent bleeding requiring hospitalization

    Inference on inspiral signals using LISA MLDC data

    Full text link
    In this paper we describe a Bayesian inference framework for analysis of data obtained by LISA. We set up a model for binary inspiral signals as defined for the Mock LISA Data Challenge 1.2 (MLDC), and implemented a Markov chain Monte Carlo (MCMC) algorithm to facilitate exploration and integration of the posterior distribution over the 9-dimensional parameter space. Here we present intermediate results showing how, using this method, information about the 9 parameters can be extracted from the data.Comment: Accepted for publication in Classical and Quantum Gravity, GWDAW-11 special issu

    Use of mechanical circulatory support devices among patients with acute myocardial infarction complicated by cardiogenic shock

    Get PDF
    Importance: Mechanical circulatory support (MCS) devices, including intravascular microaxial left ventricular assist devices (LVADs) and intra-aortic balloon pumps (IABPs), are used in patients who undergo percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) complicated by cardiogenic shock despite limited evidence of their clinical benefit. Objective: To examine trends in the use of MCS devices among patients who underwent PCI for AMI with cardiogenic shock, hospital-level use variation, and factors associated with use. Design, Setting, and Participants: This cross-sectional study used the CathPCI and Chest Pain-MI Registries of the American College of Cardiology National Cardiovascular Data Registry. Patients who underwent PCI for AMI complicated by cardiogenic shock between October 1, 2015, and December 31, 2017, were identified from both registries. Data were analyzed from October 2018 to August 2020. Exposures: Therapies to provide hemodynamic support were categorized as intravascular microaxial LVAD, IABP, TandemHeart, extracorporeal membrane oxygenation, LVAD, other devices, combined IABP and intravascular microaxial LVAD, combined IABP and other device (defined as TandemHeart, extracorporeal membrane oxygenation, LVAD, or another MCS device), or medical therapy only. Main Outcomes and Measures: Use of MCS devices overall and specific MCS devices, including intravascular microaxial LVAD, at both patient and hospital levels and variables associated with use. Results: Among the 28 304 patients included in the study, the mean (SD) age was 65.4 (12.6) years and 18 968 were men (67.0%). The overall MCS device use was constant from the fourth quarter of 2015 to the fourth quarter of 2017, although use of intravascular microaxial LVADs significantly increased (from 4.1% to 9.8%; P \u3c .001), whereas use of IABPs significantly decreased (from 34.8% to 30.0%; P \u3c .001). A significant hospital-level variation in MCS device use was found. The median (interquartile range [IQR]) proportion of patients who received MCS devices was 42% (30%-54%), and the median proportion of patients who received intravascular microaxial LVADs was 1% (0%-10%). In multivariable analyses, cardiac arrest at first medical contact or during hospitalization (odds ratio [OR], 1.82; 95% CI, 1.58-2.09) and severe left main and/or proximal left anterior descending coronary artery stenosis (OR, 1.36; 95% CI, 1.20-1.54) were patient characteristics that were associated with higher odds of receiving intravascular microaxial LVADs only compared with IABPs only. Conclusions and Relevance: This study found that, among patients who underwent PCI for AMI complicated by cardiogenic shock, overall use of MCS devices was constant, and a 2.5-fold increase in intravascular microaxial LVAD use was found along with a corresponding decrease in IABP use and a significant hospital-level variation in MCS device use. These trends were observed despite limited clinical trial evidence of improved outcomes associated with device use

    Camouflaging in a Complex Environment—Octopuses Use Specific Features of Their Surroundings for Background Matching

    Get PDF
    Living under intense predation pressure, octopuses evolved an effective and impressive camouflaging ability that exploits features of their surroundings to enable them to “blend in.” To achieve such background matching, an animal may use general resemblance and reproduce characteristics of its entire surroundings, or it may imitate a specific object in its immediate environment. Using image analysis algorithms, we examined correlations between octopuses and their backgrounds. Field experiments show that when camouflaging, Octopus cyanea and O. vulgaris base their body patterns on selected features of nearby objects rather than attempting to match a large field of view. Such an approach enables the octopus to camouflage in partly occluded environments and to solve the problem of differences in appearance as a function of the viewing inclination of the observer

    The Effectiveness of Non-pyrethroid Insecticide-treated Durable Wall Lining to Control Malaria in Rural Tanzania: Study Protocol for a Two-armed Cluster Randomized Trial.

    Get PDF
    Despite considerable reductions in malaria achieved by scaling-up long-lasting insecticidal nets (LLINs) and indoor residual spraying (IRS), maintaining sustained community protection remains operationally challenging. Increasing insecticide resistance also threatens to jeopardize the future of both strategies. Non-pyrethroid insecticide-treated wall lining (ITWL) may represent an alternate or complementary control method and a potential tool to manage insecticide resistance. To date no study has demonstrated whether ITWL can reduce malaria transmission nor provide additional protection beyond the current best practice of universal coverage (UC) of LLINs and prompt case management. A two-arm cluster randomized controlled trial will be conducted in rural Tanzania to assess whether non-pyrethroid ITWL and UC of LLINs provide added protection against malaria infection in children, compared to UC of LLINs alone. Stratified randomization based on malaria prevalence will be used to select 22 village clusters per arm. All 44 clusters will receive LLINs and half will also have ITWL installed on interior house walls. Study children, aged 6 months to 11 years old, will be enrolled from each cluster and followed monthly to estimate cumulative incidence of malaria parasitaemia (primary endpoint), time to first malaria episode and prevalence of anaemia before and after intervention. Entomological inoculation rate will be estimated using indoor CDC light traps and outdoor tent traps followed by detection of Anopheles gambiae species, sporozoite infection, insecticide resistance and blood meal source. ITWL bioefficacy and durability will be monitored using WHO cone bioassays and household surveys, respectively. Social and cultural factors influencing community and household ITWL acceptability will be explored through focus-group discussions and in-depth interviews. Cost-effectiveness, compared between study arms, will be estimated per malaria case averted. This protocol describes the large-scale evaluation of a novel vector control product, designed to overcome some of the known limitations of existing methods. If ITWL is proven to be effective and durable under field conditions, it may warrant consideration for programmatic implementation, particularly in areas with long transmission seasons and where pyrethroid-resistant vectors predominate. Trial findings will provide crucial information for policy makers in Tanzania and other malaria-endemic countries to guide resource allocations for future control efforts

    Search for gravitational wave bursts in LIGO's third science run

    Get PDF
    We report on a search for gravitational wave bursts in data from the three LIGO interferometric detectors during their third science run. The search targets subsecond bursts in the frequency range 100-1100 Hz for which no waveform model is assumed, and has a sensitivity in terms of the root-sum-square (rss) strain amplitude of hrss ~ 10^{-20} / sqrt(Hz). No gravitational wave signals were detected in the 8 days of analyzed data.Comment: 12 pages, 6 figures. Amaldi-6 conference proceedings to be published in Classical and Quantum Gravit

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 102210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200
    corecore