15 research outputs found

    Binary polymer systems for biomedical applications

    Get PDF
    Binary polymer systems provide significant advantages in the preparation of materials used in biomedical applications. To highlight the importance and need of binary polymer systems in biomedical applications; utilisations of nano-carrier and fibre are discussed in detail in terms of their use as biomaterial, and their potential for further development with focus on dual and sequential drug delivery applications. On the other hand, in fibre technology, creation of binary polymer systems have been investigated using spinning processes such as electrospinning and even more recently innovated pressurised gyration. How these methods can be used to promote the mass production of binary polymer systems with various morphologies and characteristics are elucidated. The effects of different polymer materials, including solvents, mechanical properties, and the rate of degradation of polymers, are discussed. Current polymer blending systems and manufacturing processes are analysed, and technologies for biomaterials are carefully considered with up to date details

    Pressure-Spun Fibrous Surgical Sutures for Localized Antibacterial Delivery: Development, Characterization, and In Vitro Evaluation

    Get PDF
    Surgical sutures designed to prevent infection are critical in addressing antibiotic-resistant pathogens that cause surgical site infections. Instead of antibiotics, alternative materials such as biocides have been assessed for coating commercially used sutures due to emerging antibiotic resistance concerns worldwide. This study has a new approach to the development of fibrous surgical sutures with the ability to deliver localized antibacterial agents. A new manufacturing process based on pressure spinning was used for the first time in the production of fibrous surgical sutures by physically blending antibacterial triclosan (Tri) agent with poly(lactic-co-glycolic acid) (PLGA) and poly(ethylene oxide) (PEO) polymers. Fibrous surgical sutures with virgin PLGA, virgin PEO, different ratios of PLGA-PEO, and different ratios of Tri-loaded PLGA-PEO fibrous sutures were produced to mimic the FDA- and NICE-approved PLGA-based sutures available in the market and compared for their characteristics. They were also tested simultaneously with commercially available sutures to compare their in vitro biodegradation, antibacterial, drug release, and cytotoxicity properties. After in vitro antibacterial testing for 24 h, sutures having 285 ± 12 μg/mg Tri loading were selected as a model for further testing as they exhibited antibacterial activity against all tested bacteria strains. The selected model of antibacterial fibrous sutures exhibited an initial burst of Tri release within 24 h, followed by a sustained release for the remaining time until the sutures completely degraded within 21 days. The cell viability assay showed that these surgical sutures had no cytotoxic effect on mammalian cells

    Generating Lifetime-Enhanced Microbubbles by Decorating Shells with Silicon Quantum Nano-Dots Using a 3-Series T-Junction Microfluidic Device

    Get PDF
    Long-term stability of microbubbles is crucial to their effectiveness. Using a new microfluidic device connecting three T-junction channels of 100 μm in series, stable monodisperse SiQD-loaded bovine serum albumin (BSA) protein microbubbles down to 22.8 ± 1.4 μm in diameter were generated. Fluorescence microscopy confirmed the integration of SiQD on the microbubble surface, which retained the same morphology as those without SiQD. The microbubble diameter and stability in air were manipulated through appropriate selection of T-junction numbers, capillary diameter, liquid flow rate, and BSA and SiQD concentrations. A predictive computational model was developed from the experimental data, and the number of T-junctions was incorporated into this model as one of the variables. It was illustrated that the diameter of the monodisperse microbubbles generated can be tailored by combining up to three T-junctions in series, while the operating parameters were kept constant. Computational modeling of microbubble diameter and stability agreed with experimental data. The lifetime of microbubbles increased with increasing T-junction number and higher concentrations of BSA and SiQD. The present research sheds light on a potential new route employing SiQD and triple T-junctions to form stable, monodisperse, multi-layered, and well-characterized protein and quantum dot-loaded protein microbubbles with enhanced stability for the first time

    Assessment of electromechanically stimulated bone marrow stem cells seeded acellular cardiac patch in a rat myocardial infarct model

    Get PDF
    In this study, we evaluated cardiomyogenic differentiation of electromechanically stimulated rat bone marrow-derived stem cells (rt-BMSCs) on an acellular bovine pericardium (aBP) and we looked at the functioning of this engineered patch in a rat myocardial infarct (MI) model. aBP was prepared using a detergent-based decellularization procedure followed by rt-BMSCs seeding, and electrical, mechanical, or electromechanical stimulations (3 millisecond pulses of 5 V cm-1at 1 Hz, 5% stretching) to enhance cardiomyogenic differentiation. Furthermore, the electromechanically stimulated patch was applied to the MI region over 3 weeks. After this period, the retrieved patch and infarct region were evaluated for the presence of calcification, inflammatory reaction (CD68), patch to host tissue cell migration, and structural sarcomere protein expressions. In conjunction with any sign of calcification, a higher number of BrdU-labelled cells, and a low level of CD68 positive cells were observed in the infarct region under electromechanically stimulated conditions compared with static conditions. More importantly, MHC, SAC, Troponin T, and N-cad positive cells were observed in both infarct region, and retrieved engineered patch after 3 weeks. In a clear alignment with other results, our developed acellular patch promoted the expression of cardiomyogenic differentiation factors under electromechanical stimulation. Our engineered patch showed a successful integration with the host tissue followed by the cell migration to the infarct region

    Preparation of poly(glycerol sebacate) fibers for tissue engineering applications

    Get PDF
    Poly(glycerol sebacate) (PGS) was discovered in the previous decade and is a promising bioelastomer with tuneable mechanical, biodegradable and biocompatible properties. Despite of these superiorities, PGS possesses solubility and processability disadvantages. To overcome these drawbacks of PGS, blends could be formed with a polymer which is soluble in a common solvent with PGS prepolymer, having a melting temperature above the crosslinking temperature and which can be removed from the structure after crosslinking. In this study, PGS fibers were fabricated for the first time using pressurized gyration as scaffolds. Fibers were obtained through blending the synthesized PGS prepolymer with poly(vinyl alcohol) (PVA) to overcome solubility/melting drawbacks of crosslinked PGS polymer. Obtained fiber diameters have a narrow size distribution which did not change after thermal crosslinking. After the washing procedure, ∼25% decrease in the average fiber diameter was observed due to the PVA removal. Resulting PGS fibers were characterized in terms of chemical structure, morphology, and cell viability. Fibroblast cell adhesion and spreading on three-dimensional fiber networks were determined by microscopy. PGS fibers supported cell adhesion and proliferation. After 7 days of cell-PGS fiber interactions, cell proliferation and spreading increased without any toxicity

    Polyethyleneimine brushes effectively inhibit encrustation on polyurethane ureteral stents both in dynamic bioreactor and in vivo

    No full text
    ERTAS, NUSRET/0000-0002-9770-3292WOS: 000390967200135PubMed: 27987673Polyurethane (PU) ureteral stents have been widely used as biomedical devices to aid the flow of the urine. Due to the biofilm formation and encrustation complications it has been hindered their long term clinical usage. To overcome these complications, in this study, cationic polyethyleneimine (PEI) brushes grafted on PU stents and their performances were tested both in a dynamic biofilm reactor system (in vitro) and in a rat model (in vivo). Thus, we hypothesized that PEI brushes inhibit bacterial adhesion owing to the dynamic motion of brushes in liquid environment. In addition, cationic structure of PEI disrupts the membrane and so kills the bacteria on time of contact. Cationic PEI brushes decreased the biofilm formation up to 2 orders of magnitude and approximately 50% of encrustation amount in respect to unmodified PU, in vitro. In addition, according to Atomic Absorption Spectroscopy (AAS) results, approximately 90% of encrustation was inhibited on in vivo animal models. Decrease in encrustation was clearly observed on the stents obtained from rat model, by Scanning Electron Microscopy (SEM). Also, histological evaluations showed that; PEI brush grafting decreased host tissue inflammation in close relation to decrease in biofilm formation and encrustation. As a results; dual effect of anti adhesive and contact-killing antibacterial strategy showed high efficiency on PEI brushes grafted PU stents both in vitro and in vivo. (C) 2016 Elsevier B.V. All rights reserved.Scientific and Technological Research Council Turkey of (TUBITAK) [112M293]This study is financially supported by The Scientific and Technological Research Council Turkey of (TUBITAK) (Grant no: 112M293)

    Facile One-Pot Method for All Aqueous Green Formation of Biocompatible Silk Fibroin-Poly(Ethylene Oxide) Fibers for Use in Tissue Engineering

    No full text
    Silk fibroin (SF) fibers are highly regarded in tissue engineering because of their outstanding biocompatibility and tunable properties. A challenge remains in overcoming the trade-off between functioning and biocompatible fibers and the use of cytotoxic, environmentally harmful organic solvents in their processing and formation. The aim of this research was to produce biocompatible SF fibers without the use of cytotoxic solvents, via pressurized gyration (PG). Aqueous SF was blended with poly(ethylene oxide) (PEO) in ratios of 80:20 (labeled SF-PEO 80:20) and 90:10 (labeled SF-PEO 90:10) and spun into fibers using PG, assisted by a range of applied pressures and heat. Pure PEO (labeled PEO-Aq) and SF solubilized in hexafluoro-isopropanol (HFIP) (labeled SF-HFIP) and aqueous SF (labeled SF-Aq) were also prepared for comparison. The resulting fibers were characterized using SEM, TGA, and FTIR. Their in vitro cell behavior was analyzed using a Live/Dead assay and cell proliferation studies with the SaOS-2 human bone osteosarcoma cell line (ATCC, HTB-85) and human fetal osteoblast cells (hFob) (ATCC, CRL-11372) in 2D culture conditions. Fibers in the micrometer range were successfully produced using SF-PEO blends, SF-HFIP, and PEO-Aq. The fiber thickness ranged from 0.71 ± 0.17 μm for fibers produced using SF-PEO 90:10 with no applied pressure to 2.10 ± 0.78 μm for fibers produced using SF-PEO 80:10 with 0.3 MPa applied pressure. FTIR confirmed the presence of SF via amide I and amide II bands in the blend fibers because of a change in structural conformation. No difference was observed in thermogravimetric properties among varying pressures and no significant difference in fiber diameters for pressures. SaOS-2 cells and hFOb cell studies demonstrated higher cell densities and greater live cells on SF-PEO blends when compared to SF-HFIP. This research demonstrates a scalable and green method of producing SF-based constructs for use in bone-tissue engineering applications

    Honeycomb-like PLGA‑<i>b</i>‑PEG Structure Creation with T‑Junction Microdroplets

    No full text
    Amphiphilic block copolymers are widely used in science owing to their versatile properties. In this study, amphiphilic block copolymer poly­(lactic-<i>co</i>-glycolic acid)-<i>block</i>-poly­(ethylene glycol) (PLGA-<i>b</i>-PEG) was used to create microdroplets in a T-junction microfluidic device with a well-defined geometry. To compare interfacial characteristics of microdroplets, dichloromethane (DCM) and chloroform were used to prepare PLGA-<i>b</i>-PEG solution as an oil phase. In the T-junction device, water and oil phases were manipulated at variable flow rates from 50 to 300 μL/min by increments of 50 μL/min. Fabricated microdroplets were directly collected on a glass slide. After a drying period, porous two-dimensional and three-dimensional structures were obtained as honeycomb-like structure. Pore sizes were increased according to increased water/oil flow rate for both DCM and chloroform solutions. Also, it was shown that increasing polymer concentration decreased the pore size of honeycomb-like structures at a constant water/oil flow rate (50:50 μL/min). Additionally, PLGA-<i>b</i>-PEG nanoparticles were also obtained on the struts of honeycomb-like structures according to the water solubility, volatility, and viscosity properties of oil phases, by the aid of Marangoni flow. The resulting structures have a great potential to be used in biomedical applications, especially in drug delivery-related studies, with nanoparticle forming ability and cellular responses in different surface morphologies

    Honeycomb-like PLGA‑<i>b</i>‑PEG Structure Creation with T‑Junction Microdroplets

    No full text
    Amphiphilic block copolymers are widely used in science owing to their versatile properties. In this study, amphiphilic block copolymer poly­(lactic-<i>co</i>-glycolic acid)-<i>block</i>-poly­(ethylene glycol) (PLGA-<i>b</i>-PEG) was used to create microdroplets in a T-junction microfluidic device with a well-defined geometry. To compare interfacial characteristics of microdroplets, dichloromethane (DCM) and chloroform were used to prepare PLGA-<i>b</i>-PEG solution as an oil phase. In the T-junction device, water and oil phases were manipulated at variable flow rates from 50 to 300 μL/min by increments of 50 μL/min. Fabricated microdroplets were directly collected on a glass slide. After a drying period, porous two-dimensional and three-dimensional structures were obtained as honeycomb-like structure. Pore sizes were increased according to increased water/oil flow rate for both DCM and chloroform solutions. Also, it was shown that increasing polymer concentration decreased the pore size of honeycomb-like structures at a constant water/oil flow rate (50:50 μL/min). Additionally, PLGA-<i>b</i>-PEG nanoparticles were also obtained on the struts of honeycomb-like structures according to the water solubility, volatility, and viscosity properties of oil phases, by the aid of Marangoni flow. The resulting structures have a great potential to be used in biomedical applications, especially in drug delivery-related studies, with nanoparticle forming ability and cellular responses in different surface morphologies

    Pressure-Spun Fibrous Surgical Sutures for Localized Antibacterial Delivery: Development, Characterization, and In Vitro Evaluation

    No full text
    Surgical sutures designed to prevent infection are critical in addressing antibiotic-resistant pathogens that cause surgical site infections. Instead of antibiotics, alternative materials such as biocides have been assessed for coating commercially used sutures due to emerging antibiotic resistance concerns worldwide. This study has a new approach to the development of fibrous surgical sutures with the ability to deliver localized antibacterial agents. A new manufacturing process based on pressure spinning was used for the first time in the production of fibrous surgical sutures by physically blending antibacterial triclosan (Tri) agent with poly(lactic-co-glycolic acid) (PLGA) and poly(ethylene oxide) (PEO) polymers. Fibrous surgical sutures with virgin PLGA, virgin PEO, different ratios of PLGA–PEO, and different ratios of Tri-loaded PLGA–PEO fibrous sutures were produced to mimic the FDA- and NICE-approved PLGA-based sutures available in the market and compared for their characteristics. They were also tested simultaneously with commercially available sutures to compare their in vitro biodegradation, antibacterial, drug release, and cytotoxicity properties. After in vitro antibacterial testing for 24 h, sutures having 285 ± 12 μg/mg Tri loading were selected as a model for further testing as they exhibited antibacterial activity against all tested bacteria strains. The selected model of antibacterial fibrous sutures exhibited an initial burst of Tri release within 24 h, followed by a sustained release for the remaining time until the sutures completely degraded within 21 days. The cell viability assay showed that these surgical sutures had no cytotoxic effect on mammalian cells
    corecore