1,464 research outputs found
Velocity of sound in a Bose-Einstein condensate in the presence of an optical lattice and transverse confinement
We study the effect of the transverse degrees of freedom on the velocity of
sound in a Bose-Einstein condensate immersed in a one-dimensional optical
lattice and radially confined by a harmonic trap. We compare the results of
full three-dimensional calculations with those of an effective 1D model based
on the equation of state of the condensate. The perfect agreement between the
two approaches is demonstrated for several optical lattice depths and
throughout the full crossover from the 1D mean-field to the Thomas Fermi regime
in the radial direction.Comment: final versio
Diamonds as timing detectors for MIP: The HADES proton-beam monitor and start detectors
This paper gives an overview of a recent development of measuring time of
flight of minimum-ionizing particles (MIP) with mono-crystalline diamond
detectors. The application in the HADES spectrometer as well as test results
obtained with proton beams are discussed.Comment: submitted to Nuclear Instruments and Methods
First-Principles Study on Electron Conduction in Sodium Nanowire
We present detailed first-principles calculations of the electron-conduction
properties of a three-sodium-atom nanowire suspended between semi-infinite
crystalline Na(001) electrodes during its elongation. Our investigations reveal
that the conductance is ~1 G0 before the nanowire breaks and only one channel
with the characteristic of the orbital of the center atom in the nanowire
contributes to the electron conduction. Moreover, the channel fully opens
around the Fermi level, and the behavior of the channel-current density is
insensitive to the structural deformation of the nanowire. These results verify
that the conductance trace as a function of the electrode spacing exhibits a
flat plateau at ~1 G0 during elongation.Comment: 8 pages, 5 figure
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
PURPOSE: Loss of photoreceptors in atrophic age-related macular degeneration results in severe visual impairment, although some peripheral vision is retained. To restore central vision without compromising the residual peripheral field, we developed a wireless photovoltaic retinal implant (PRIMA; Pixium Vision, Paris, France) in which pixels convert images projected from video glasses using near-infrared light into electric current to stimulate the nearby inner retinal neurons. DESIGN: We carried out a first-in-human clinical trial to test the safety and efficacy of the prosthesis in patients with geographic atrophy (ClinicalTrials.gov identifier, NCT03333954). PARTICIPANTS: Five patients with geographic atrophy zone of at least 3 optic disc diameters, no foveal light perception, and best-corrected visual acuity of 20/400 to 20/1000 in the worse-seeing study eye. METHODS: The 2-mm wide, 30-μm thick chip, containing 378 pixels (each 100 μm in diameter), was implanted subretinally in the area of atrophy (absolute scotoma). MAIN OUTCOME MEASURES: Anatomic outcomes were assessed with fundus photography and OCT for up to 12 months of follow-up. Prosthetic vision was assessed by mapping light perception, bar orientation, letter recognition, and Landolt C acuity. RESULTS: In all patients, the prosthesis was implanted successfully under the macula, although in 2 patients, it was implanted in unintended locations: within the choroid and off center by 2 mm. All 5 patients could perceive white-yellow prosthetic visual patterns with adjustable brightness in the previous scotomata. The 3 with optimal placement of the implant demonstrated prosthetic acuity of 20/460 to 20/550, and the patient with the off-center implant demonstrated 20/800 acuity. Residual natural acuity did not decrease after implantation in any patient. CONCLUSIONS: Implantation of the PRIMA did not decrease the residual natural acuity, and it restored visual sensitivity in the former scotoma in each of the 5 patients. In 3 patients with the proper placement of the chip, prosthetic visual acuity was only 10% to 30% less than the level expected from the pixel pitch (20/420). Therefore, the use of optical or electronic magnification in the glasses as well as smaller pixels in future implants may improve visual acuity even further
Guaranteeing Canadian lamb meat quality using near-infrared spectroscopy on intact rack
Lamb racks from commercial carcasses were scanned using near-infrared spectroscopy. The prediction accuracies (R 2) for meat quality traits were assessed. Prediction accuracy ranged between 0.40 and 0.94. When predicted values were used to classify meat based on quality, 88.7%–95.2% of samples were correctly classified as quality guaranteed
Challenges around COVID-19 at a tertiary-level healthcare facility in South Africa and strategies implemented for improvement
SARS-CoV-2 has resulted in a global pandemic within months following its initial detection. South Africa (SA), like many other countries, was not prepared for the impact this novel infection would have on the healthcare system. In this paper, the authors discuss the challenges experienced while facing COVID-19 at a tertiary-level institution in Gauteng province, SA, and the dynamic strategies implemented to deal with the epidemic
- …