13 research outputs found

    Thermodynamic performance testing of the orbiter flash evaporator system

    Get PDF
    System level testing of the space shuttle orbiter's development flash evaporator system (FES) was performed in a thermal vacuum chamber capable of simulating ambient ascent, orbital, and entry temperature and pressure profiles. The test article included the evaporator assembly, high load and topping exhaust duct and nozzle assemblies, and feedwater supply assembly. Steady state and transient heat load, water pressure/temperature and ambient pressure/temperature profiles were imposed by especially designed supporting test hardware. Testing in 1978 verified evaporator and duct heater thermal design, determined FES performance boundaries, and assessed topping evaporator plume characteristics. Testing in 1979 combined the FES with the other systems in the orbiter active thermal control subsystem (ATCS). The FES met or exceeded all nominal and contingency performance requirements during operation with the integrated ATCS. During both tests stability problems were encountered during steady state operations which resulted in subsequent design changes to the water spray nozzle and valve plate assemblies

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    Get PDF
    Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957

    Unmet diagnostic needs in contact oral mucosal allergies

    Get PDF
    The oral mucosa including the lips is constantly exposed to several noxious stimuli, irritants and allergens. However, oral contact pathologies are not frequently seen because of the relative resistance of the oral mucosa to irritant agents and allergens due to anatomical and physiological factors. The spectrum of signs and symptoms of oral contact allergies (OCA) is broad and a large number of condition can be the clinical expression of OCA such as allergic contact stomatitis, allergic contact cheilitis, geographic tongue, oral lichenoid reactions, burning mouth syndrome. The main etiological factors causing OCA are dental materials, food and oral hygiene products, as they contain flavouring agents and preservatives. The personal medical history of the patient is helpful to perform a diagnosis, as a positive history for recent dental procedures. Sometimes histology is mandatory. When it cannot identify a direct cause of a substance, in both acute and chronic OCA, patch tests can play a pivotal role in the diagnosis. However, patch tests might have several pitfalls. Indeed, the presence of metal ions as haptens and specifically the differences in their concentrations in oral mucosa and in standard preparation for patch testing and in the differences in pH of the medium might result in either false positive/negative reactions or non-specific irritative reactions. Another limitation of patch test results is the difficulty to assess the clinical relevance of haptens contained in dental materials and only the removal of dental materials or the avoidance of other contactant and consequent improvement of the disease may demonstrate the haptens' responsibility. In conclusion, the wide spectrum of clinical presentations, the broad range of materials and allergens which can cause it, the difficult interpretation of patch-test results, the clinical relevance assessment of haptens found positive at patch test are the main factors that make sometimes difficult the diagnosis and the management of OCA that requires an interdisciplinary approach to the patient

    Thrombin-receptor antagonist vorapaxar in acute coronary syndromes

    No full text
    BACKGROUND Vorapaxar is a new oral protease-activated–receptor 1 (PAR-1) antagonist that inhibits thrombin-induced platelet activation. METHODS In this multinational, double-blind, randomized trial, we compared vorapaxar with placebo in 12,944 patients who had acute coronary syndromes without ST-segment elevation. The primary end point was a composite of death from cardiovascular causes, myocardial infarction, stroke, recurrent ischemia with rehospitalization, or urgent coronary revascularization. RESULTS Follow-up in the trial was terminated early after a safety review. After a median follow-up of 502 days (interquartile range, 349 to 667), the primary end point occurred in 1031 of 6473 patients receiving vorapaxar versus 1102 of 6471 patients receiving placebo (Kaplan–Meier 2-year rate, 18.5% vs. 19.9%; hazard ratio, 0.92; 95% confidence interval [CI], 0.85 to 1.01; P = 0.07). A composite of death from cardiovascular causes, myocardial infarction, or stroke occurred in 822 patients in the vorapaxar group versus 910 in the placebo group (14.7% and 16.4%, respectively; hazard ratio, 0.89; 95% CI, 0.81 to 0.98; P = 0.02). Rates of moderate and severe bleeding were 7.2% in the vorapaxar group and 5.2% in the placebo group (hazard ratio, 1.35; 95% CI, 1.16 to 1.58; P<0.001). Intracranial hemorrhage rates were 1.1% and 0.2%, respectively (hazard ratio, 3.39; 95% CI, 1.78 to 6.45; P<0.001). Rates of nonhemorrhagic adverse events were similar in the two groups. CONCLUSIONS In patients with acute coronary syndromes, the addition of vorapaxar to standard therapy did not significantly reduce the primary composite end point but significantly increased the risk of major bleeding, including intracranial hemorrhage

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    No full text
    corecore