1,079 research outputs found

    ZLZ_L associated pair production of charged Higgs bosons in the littlest Higgs model at e+ee^{+}e^{-} colliders

    Get PDF
    The production of single and doubly charged Higgs bosons associated with standard model gauge boson ZLZ_L in e+ee^{+}e^{-} colliders are examined. The sensitivity of these processes on the littlest Higgs model parameters in the range of compatibility with electroweak precision observables are analyzed. The possibility of detecting lepton flavor violation processes are also discussed.Comment: 20 pages, 5 figures, version published in Physical Review

    Japan and Europe Network for Neutrino and Intensity Frontier Experimental Research (JENNIFER)

    Get PDF
    European particle physics groups interested in searching signals of new physics both with neutrinos, at T2K experiment, and at the intensity frontier, with the Belle-II experiment at the SUPERKEKB machine, want to share between them and with KEK laboratory their knowledge in data analysis and detector technologies. Such knowledge sharing will enhance skills and competences of all participants, will allow Europe to play a primary role in the search for deviations from the actually known fundamental physics in the flavour sector and, last but not least, will produce an unprecedented collaboration with japanese scientists on the ground of dissemination and outreach.MSCA-RISE - Marie Skłodowska-Curie Research and Innovation Staff Exchange (RISE) (H2020-MSCA-RISE-2014

    Child-Pugh classification dependent alterations in serum leptin levels among cirrhotic patients: a case controlled study

    Get PDF
    BACKGROUND: As anorexia and hypermetabolism are common in cirrhosis, leptin levels may be increased in this disease. In this study, we investigated the relation between the severity of disease and serum leptin levels in post-hepatitis cirrhosis and the role of body composition, gender and viral aetiology of cirrhosis in this association. METHODS: Thirty-five cases with post-hepatitis cirrhosis and 15 healthy controls were enrolled in this study. Body composition including body mass index, body fat percentage and body fat mass were determined. Serum leptin levels were assayed. RESULTS: Leptin levels were significantly higher among cirrhotic patients independent of sex compared to controls (p = 0.001). Female patients in both groups have had higher leptin levels than males (in cirrhotics p = 0.029, in controls p = 0.02). Cirrhotic patients in each of A, B and C subgroups according to the Child- Pugh classification revealed significantly different levels compared to controls (p = 0.046, p = 0.004, p = 0.0001, respectively). Male cirrhotics in Child-Pugh Class B and C subgroups had significantly higher leptin levels compared to male controls (p = 0.006, p = 0.008). On the other hand, female patients only in Child Pugh class C subgroup have had higher levels of serum leptin compared to controls (p = 0.022). Child-Pugh classification has been found to be the sole discriminator in determination of leptin levels in cirrhotics by linear regression (beta: 0.435 p = 0.015). CONCLUSION: Serum leptin levels increase in advanced liver disease independently of gender, body composition in posthepatitic cirrhosis. The increase is more abundant among patients that belong to C subgroup according to the Child- Pugh classification

    Constraints on scalar-pseudoscalar and tensorial nonstandard interactions and tensorial unparticle couplings from neutrino-electron scattering

    Get PDF
    Neutrino-electron scattering is a purely leptonic fundamental interaction and therefore provides an important channel to test the Standard Model, especially at the low energy-momentum transfer regime. We derived constraints on neutrino nonstardard interaction couplings depending on model-independent approaches which are described by a four-Fermi pointlike interaction and the unparticle physics model with tensorial components. Data on (nu) over bar (e) - e and nu(e) - e scattering from the TEXONO and LSND experiments, respectively, are used. The upper limits and the allowed regions of scalar, pseudoscalar, and tensorial nonstandard interaction couplings of neutrinos are derived at 90% confidence level in both one-parameter and two-parameter analysis. New upper limits for tensorial unparticle physics coupling constants and mass parameters are also placed

    Design and performance of a hybrid fast and thermal neutron detector

    Get PDF
    We report the characterization, calibration and performance of a custom-built hybrid detector consisting of BC501A liquid scintillator and BC702 scintillator for the detection of fast and thermal neutrons, respectively. Pulse Shape Discrimination techniques are developed to distinguish events due to gamma-rays, fast and thermal neutrons. Software analysis packages are developed to derive raw neutron energy spectra from measured proton recoil spectra. The validity is demonstrated through the reconstruction of the (AmBe)-Am-241(alpha,n) neutron spectrum. (C) 2017 Elsevier B. V. All rights reserved

    Characteristics of food allergy in children: National multicenter study

    Get PDF
    Conference: Congress of the European-Academy-of-Allergy-and-Clinical-Immunology (EAACI) Location: Lisbon, PORTUGAL Date: JUN 01-05, 2019Background : Food allergies impose a significant burden on the life of the child and the family. In this study, to determine the demographic characteristics of food allergies, we investigated the characteristics of patients with food allergies in different regions of Pediatric Allergy- Immunology departments in Turkey. Method : Turkey ' s National Study of Allergy and Clinical Immunology Society has conducted a Study Group on Food Allergies. 25 centers participated in this multicenter, cross- sectional and descriptive study.European Academy of Allergy and Clinical Immunolog

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%
    corecore