158 research outputs found
Comparative ergonomic workflow and user experience analysis of MRI versus fluoroscopy-guided vascular interventions:an iliac angioplasty exemplar case study
Purpose A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Methods Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stagesâ durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Results Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. Conclusions This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education
Durability and inflammogenic impact of carbon nanotubes compared with asbestos fibres
<p>Abstract</p> <p>Background</p> <p>It has been suggested that carbon nanotubes might conform to the fibre pathogenicity paradigm that explains the toxicities of asbestos and other fibres on a continuum based on length, aspect ratio and biopersistence. Some types of carbon nanotubes satisfy the first two aspects of the fibre paradigm but only recently has their biopersistence begun to be investigated. Biopersistence is complex and requires <it>in vivo </it>testing and analysis. However durability, the chemical mimicking of the process of fibre dissolution using <it>in vitro </it>treatment, is closely related to biopersistence and more readily determined. Here, we describe an experimental process to determine the durability of four types of carbon nanotubes in simulated biological fluid (Gambles solution), and their subsequent pathogenicity <it>in vivo </it>using a mouse model sensitive to inflammogenic effects of fibres. The <it>in vitro </it>and <it>in vivo </it>results were compared with well-characterised glass wool and asbestos fibre controls.</p> <p>Results</p> <p>After incubation for up to 24 weeks in Gambles solution, our control fibres were recovered at percentages consistent with their known <it>in vitro </it>durabilities and/or <it>in vivo </it>persistence, and three out of the four types of carbon nanotubes tested (single-walled (CNT<sub>SW</sub>) and multi-walled (CNT<sub>TANG2</sub>, CNT<sub>SPIN</sub>)) showed no, or minimal, loss of mass or change in fibre length or morphology when examined by electron microscopy. However, the fourth type [multi-walled (CNT<sub>LONG1</sub>)] lost 30% of its original mass within the first three weeks of incubation, after which there was no further loss. Electron microscopy of CNT<sub>LONG1 </sub>samples incubated for 10 weeks confirmed that the proportion of long fibres had decreased compared to samples briefly exposed to the Gambles solution. This loss of mass and fibre shortening was accompanied by a loss of pathogenicity when injected into the peritoneal cavities of C57Bl/6 mice compared to fibres incubated briefly. CNT<sub>SW </sub>did not elicit an inflammogenic effect in the peritoneal cavity assay used here.</p> <p>Conclusions</p> <p>These results support the view that carbon nanotubes are generally durable but may be subject to bio-modification in a sample-specific manner. They also suggest that pristine carbon nanotubes, either individually or in rope-like aggregates of sufficient length and aspect ratio, can induce asbestos-like responses in mice, but that the effect may be mitigated for certain types that are less durable in biological systems. Results indicate that durable carbon nanotubes that are either short or form tightly bundled aggregates with no isolated long fibres are less inflammogenic in fibre-specific assays.</p
Recommended from our members
<i>Toxoplasma gondii</i> peptide ligands open the gate of the HLA class I binding groove
HLA class I presentation of pathogen-derived peptide ligands is essential for CD8+ T-cell recognition of Toxoplasma gondii infected cells. Currently, little data exist pertaining to peptides that are presented after T. gondii infection. Herein we purify HLA-A*02:01 complexes from T. gondii infected cells and characterize the peptide ligands using LCMS. We identify 195 T. gondii encoded ligands originating from both secreted and cytoplasmic proteins. Surprisingly, T. gondii ligands are significantly longer than uninfected host ligands, and these longer pathogen-derived peptides maintain a canonical N-terminal binding core yet exhibit a C-terminal extension of 1-30 amino acids. Structural analysis demonstrates that binding of extended peptides opens the HLA class I F' pocket, allowing the C-terminal extension to protrude through one end of the binding groove. In summary, we demonstrate that unrealized structural flexibility makes MHC class I receptive to parasite-derived ligands that exhibit unique C-terminal peptide extensions
Interventions to help coral reefs under global change â a complex decision challenge
Climate change is impacting coral reefs now. Recent pan-tropical bleaching events driven by unprecedented global heat waves have shifted the playing field for coral reef
management and policy. While best-practice conventional management remains essential, it may no longer be enough to sustain coral reefs under continued climate
change. Nor will climate change mitigation be sufficient on its own. Committed warming and projected reef decline means solutions must involve a portfolio of mitigation, best practice conventional management and coordinated restoration and adaptation measures involving new and perhaps radical interventions. We propose that proactive research and development to expand the reef management toolbox fast but safely, combined with expedient trialling of promising interventions is now urgently needed, whatever emissions trajectory the world follows. We discuss the challenges and
opportunities of embracing new interventions in a race against time, including their risks and uncertainties. Ultimately, solutions to the climate challenge for coral reefs will require consideration of what society wants, what can be achieved technically and economically, and what opportunities we have for action in a rapidly closing window.
Finding solutions that work for coral reefs and people will require exceptional levels of coordination of science, management and policy, and open engagement with society. It
will also require compromise, because reefs will change under climate change despiteour best interventions. We argue that being clear about societyâs priorities, and
understanding both the opportunities and risks that come with an expanded toolset, can help us make the most of a challenging situation
The Far-Infrared Spectral Energy Distributions of X-ray-selected Active Galaxies
[Abridged] We present ISO far-infrared (IR) observations of 21 hard X-ray
selected AGN from the HEAO-1 A2 sample. We compare the far-IR to X-ray spectral
energy distributions (SEDs) of this sample with various radio and optically
selected AGN samples. The hard-X-ray selected sample shows a wider range of
optical/UV shapes extending to redder near-IR colors. The bluer objects are
Seyfert 1s, while the redder AGN are mostly intermediate or type 2 Seyferts.
This is consistent with a modified unification model in which the amount of
obscuring material increases with viewing angle and may be clumpy. Such a
scenario, already suggested by differing optical/near-IR spectroscopic and
X-ray AGN classifications, allows for different amounts of obscuration of the
continuum emission in different wavebands and of the broad emission line region
which results in a mixture of behaviors for AGN with similar optical emission
line classifications. The resulting limits on the column density of obscuring
material through which we are viewing the redder AGN are 100 times lower than
for the standard optically thick torus models. The resulting decrease in
optical depth of the obscuring material allows the AGN to heat more dust at
larger radial distances. We show that an AGN-heated, flared, dusty disk with
mass 10^9 solar and size of few hundred pc is able to generate optical-far-IR
SEDs which reproduce the wide range of SEDs present in our sample with no need
for an additional starburst component to generate the long-wavelength, cooler
part of the IR continuum.Comment: 40 pages, 14 figures, accepted for publication in Astrophysical
Journal, V. 590, June 10, 200
Effects of High-Volume Versus High-Load Resistance Training on Skeletal Muscle Growth and Molecular Adaptations
We evaluated the effects of higher-load (HL) versus (lower-load) higher-volume (HV) resistance training on skeletal muscle hypertrophy, strength, and muscle-level molecular adaptations. Trained men (nâ=â15, age: 23â±â3âyears; training experience: 7â±â3âyears) performed unilateral lower-body training for 6âweeks (3Ă weekly), where single legs were randomly assigned to HV and HL paradigms. Vastus lateralis (VL) biopsies were obtained prior to study initiation (PRE) as well as 3âdays (POST) and 10âdays following the last training bout (POSTPR). Body composition and strength tests were performed at each testing session, and biochemical assays were performed on muscle tissue after study completion. Two-way within-subject repeated measures ANOVAs were performed on most dependent variables, and tracer data were compared using dependent samples t-tests. A significant interaction existed for VL muscle cross-sectional area (assessed via magnetic resonance imaging; interaction pâ=â0.046), where HV increased this metric from PRE to POST (+3.2%, pâ=â0.018) whereas HL training did not (â0.1%, pâ=â0.475). Additionally, HL increased leg extensor strength more so than HV training (interaction pâ=â0.032; HVâ\u3câHL at POST and POSTPR, pâ\u3câ0.025 for each). Six-week integrated non-myofibrillar protein synthesis (iNon-MyoPS) rates were also higher in the HV versus HL condition, while no difference between conditions existed for iMyoPS rates. No interactions existed for other strength, VL morphology variables, or the relative abundances of major muscle proteins. Compared to HL training, 6âweeks of HV training in previously trained men optimizes VL hypertrophy in lieu of enhanced iNon-MyoPS rates, and this warrants future research
UBVRI Light Curves of 44 Type Ia Supernovae
We present UBVRI photometry of 44 type-Ia supernovae (SN Ia) observed from
1997 to 2001 as part of a continuing monitoring campaign at the Fred Lawrence
Whipple Observatory of the Harvard-Smithsonian Center for Astrophysics. The
data set comprises 2190 observations and is the largest homogeneously observed
and reduced sample of SN Ia to date, nearly doubling the number of
well-observed, nearby SN Ia with published multicolor CCD light curves. The
large sample of U-band photometry is a unique addition, with important
connections to SN Ia observed at high redshift. The decline rate of SN Ia
U-band light curves correlates well with the decline rate in other bands, as
does the U-B color at maximum light. However, the U-band peak magnitudes show
an increased dispersion relative to other bands even after accounting for
extinction and decline rate, amounting to an additional ~40% intrinsic scatter
compared to B-band.Comment: 84 authors, 71 pages, 51 tables, 10 figures. Accepted for publication
in the Astronomical Journal. Version with high-res figures and electronic
data at http://astron.berkeley.edu/~saurabh/cfa2snIa
- âŠ