220 research outputs found

    Pure iterative reconstruction improves image quality in computed tomography of the abdomen and pelvis acquired at substantially reduced radiation doses in patients with active Crohn disease

    Get PDF
    Objective: We assessed diagnostic accuracy and image quality of modified protocol (MP) computed tomography (CT) of the abdomen and pelvis reconstructed using pure iterative reconstruction (IR) in patients with Crohn disease (CD). Methods: Thirty-four consecutive patients with CD were referred with suspected extramural complications. Two contemporaneous CT datasets were acquired in all patients: standard protocol (SP) and MP. The MP and SP protocols were designed to impart radiation exposures of 10% to 20% and 80% to 90% of routine abdominopelvic CT, respectively. The MP images were reconstructed with model-based IR (MBIR) and adaptive statistical IR (ASIR). Results: The MP-CT and SP-CT dose length product were 88 (58) mGy.cm (1.27 [0.87] mSv) and 303 [204] mGy.cm (4.8 [2.99] mSv), respectively (P < 0.001). Median diagnostic acceptability, spatial resolution, and contrast resolution were significantly higher and subjective noise scores were significantly lower on SP-ASIR 40 compared with all MP datasets. There was perfect clinical agreement between MP-MBIR and SP-ASIR 40 images for detection of extramural complications. Conclusions: Modified protocol CT using pure IR is feasible for assessment of active CD

    Nystagmus Assessments Documented by Emergency Physicians in Acute Dizziness Presentations: A Target for Decision Support?

    Full text link
    Objectives:  Dizziness is a common presenting complaint to the emergency department (ED), and emergency physicians (EPs) consider these presentations a priority for decision support. Assessing for nystagmus and defining its features are important steps for any acute dizziness decision algorithm. The authors sought to describe nystagmus documentation in routine ED care to determine if nystagmus assessments might be an important target in decision support efforts. Methods:  Medical records from ED visits for dizziness were captured as part of a surveillance study embedded within an ongoing population‐based cohort study. Visits with documentation of a nystagmus assessment were reviewed and coded for presence or absence of nystagmus, ability to draw a meaningful inference from the description, and coherence with the final EP diagnosis when a peripheral vestibular diagnosis was made. Results:  Of 1,091 visits for dizziness, 887 (81.3%) documented a nystagmus assessment. Nystagmus was present in 185 of 887 (20.9%) visits. When nystagmus was present, no further characteristics were recorded in 48 of the 185 visits (26%). The documentation of nystagmus (including all descriptors recorded) enabled a meaningful inference about the localization or cause in only 10 of the 185 (5.4%) visits. The nystagmus description conflicted with the EP diagnosis in 113 (80.7%) of the 140 visits that received a peripheral vestibular diagnosis. Conclusions:  Nystagmus assessments are frequently documented in acute dizziness presentations, but details do not generally enable a meaningful inference. Recorded descriptions usually conflict with the diagnosis when a peripheral vestibular diagnosis is rendered. Nystagmus assessments might be an important target in developing decision support for dizziness presentations.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/86927/1/j.1553-2712.2011.01093.x.pd

    IgG antibody production and persistence to 6 months following SARS-CoV-2 vaccination: a Northern Ireland observational study

    Get PDF
    BACKGROUND: This study evaluates spike protein IgG antibody response following Oxford-AstraZeneca COVID-19 vaccination using the AbC-19™ lateral flow device. METHODS: Plasma samples were collected from n=111 individuals from Northern Ireland. The majority were >50 years old and/or clinically vulnerable. Samples were taken at five timepoints from pre-vaccination until 6-months post-first dose. RESULTS: 20.3% of participants had detectable IgG responses pre-vaccination, indicating prior COVID-19. Antibodies were detected in 86.9% of participants three weeks after the first vaccine dose, falling to 74.7% immediately prior to the second dose, and rising to 99% three weeks post-second vaccine. At 6-months post-first dose, this decreased to 90.5%. At all timepoints, previously infected participants had significantly higher antibody levels than those not previously infected. CONCLUSION: This study demonstrates that strong anti-spike protein antibody responses are evoked in almost all individuals that receive two doses of Oxford-AstraZeneca vaccine, and largely persist beyond six months after first vaccination

    Discovery and Timing of Millisecond Pulsars with the Arecibo 327 MHz Drift-Scan Survey

    Full text link
    We present the discovery and timing solutions of four millisecond pulsars (MSPs) discovered in the Arecibo 327 MHz Drift-Scan Pulsar Survey. Three of these pulsars are in binary systems, consisting of a redback (PSR J2055+1545), a black widow (PSR J1630+3550), and a neutron star-white dwarf binary (PSR J2116+1345). The fourth MSP, PSR J2212+2450, is isolated. We present the multi-year timing solutions as well as polarization properties across a range of radio frequencies for each pulsar. We perform a multi-wavelength search for emission from these systems and find an optical counterpart for PSR J2055+1545 in Gaia DR3, as well as a gamma-ray counterpart for PSR J2116+1345 with the Fermi-LAT telescope. Despite the close co-location of PSR J2055+1545 with a Fermi source, we are unable to detect gamma-ray pulsations, likely due to the large orbital variability of the system. This work presents the first two binaries found by this survey with orbital periods shorter than a day; we expect to find more in the 40% of the survey data which have yet to be searched.Comment: 20 pages, 11 figures, 4 tables. Submitted to Ap

    Quantitative assessment of the conjunctival microcirculation using a smartphone and slit-lamp biomicroscope

    Get PDF
    Purpose: The conjunctival microcirculation is a readily-accessible vascular bed for quantitative haemodynamic assessment and has been studied previously using a digital charge-coupled device (CCD). Smartphone video imaging of the conjunctiva, and haemodynamic parameter quantification, represents a novel approach. We report the feasibility of smartphone video acquisition and subsequent haemodynamic measure quantification via semi-automated means. Methods: Using an Apple iPhone 6 s and a Topcon SL-D4 slit-lamp biomicroscope, we obtained videos of the conjunctival microcirculation in 4 fields of view per patient, for 17 low cardiovascular risk patients. After image registration and processing, we quantified the diameter, mean axial velocity, mean blood volume flow, and wall shear rate for each vessel studied. Vessels were grouped into quartiles based on their diameter i.e. group 1 (&lt;11 μm), 2 (11–16 μm), 3 (16–22 μm) and 4 (&gt;22 μm). Results: From the 17 healthy controls (mean QRISK3 6.6%), we obtained quantifiable haemodynamics from 626 vessel segments. The mean diameter of microvessels, across all sites, was 21.1μm (range 5.8–58 μm). Mean axial velocity was 0.50mm/s (range 0.11–1mm/s) and there was a modestly positive correlation (r 0.322) seen with increasing diameter, best appreciated when comparing group 4 to the remaining groups (p &lt; .0001). Blood volume flow (mean 145.61pl/s, range 7.05–1178.81pl/s) was strongly correlated with increasing diameter (r 0.943, p &lt; .0001) and wall shear rate (mean 157.31 s − 1, range 37.37–841.66 s − 1) negatively correlated with increasing diameter (r − 0.703, p &lt; .0001). Conclusions: We, for the first time, report the successful assessment and quantification of the conjunctival microcirculatory haemodynamics using a smartphone-based system. </p

    FLIP: A Targetable Mediator of Resistance to Radiation in Non-Small Cell Lung Cancer

    Get PDF
    Resistance to radiotherapy due to insufficient cancer cell death is a significant cause of treatment failure in non-small cell lung cancer (NSCLC). The endogenous caspase-8 inhibitor, FLIP, is a critical regulator of cell death that is frequently overexpressed in NSCLC and is an established inhibitor of apoptotic cell death induced via the extrinsic death receptor pathway. Apoptosis induced by ionizing radiation (IR) has been considered to be mediated predominantly via the intrinsic apoptotic pathway; however, we found that IR-induced apoptosis was significantly attenuated in NSCLC cells when caspase-8 was depleted using RNA interference (RNAi), suggesting involvement of the extrinsic apoptosis pathway. Moreover, overexpression of wild-type FLIP, but not a mutant form that cannot bind the critical death receptor adaptor protein FADD, also attenuated IR-induced apoptosis, confirming the importance of the extrinsic apoptotic pathway as a determinant of response to IR in NSCLC. Importantly, when FLIP protein levels were down-regulated by RNAi, IRinduced cell death was significantly enhanced. The clinically relevant histone deacetylase (HDAC) inhibitors vorinostat and entinostat were subsequently found to sensitize a subset of NSCLC cell lines to IR in a manner that was dependent on their ability to suppress FLIP expression and promote activation of caspase-8. Entinostat also enhanced the anti-tumor activity of IR in vivo. Therefore, FLIP down-regulation induced by HDAC inhibitors is a potential clinical strategy to radio-sensitize NSCLC and thereby improve response to radiotherapy. Overall, this study provides the first evidence that pharmacological inhibition of FLIP may improve response of NCSLC to IR
    corecore