1,303 research outputs found
CCS from industrial sources
The literature concerning the application of CCS to industry is reviewed. Costs are presented for different sectors including ``high purity'' (processes which inherently produce a high concentration of CO2), cement, iron and steel, refinery and biomass. The application of CCS to industry is a field which has had much less attention than its application to the electricity production sector. Costs range from less than 2011 100/tCO 2 . In the words of a synthesis report from the United Nations Industrial Development Organisation (UNIDO) ``This area has so far not been the focus of discussions and therefore much attention needs to be paid to the application of CCS to industrial sources if the full potential of CCS is to be unlocked''
Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon Breakdown Apparatus (XeBrA) is a 5-liter cryogenic chamber built to characterize the DC high voltage breakdown behavior of liquid xenon and liquid argon. Electrodes with areas up to 33 cm2 were tested while varying the cathode-anode separation from 1 to 6 mm with a voltage difference up to 75 kV. A power-law relationship between breakdown field and electrode area was observed. The breakdown behavior of liquid argon and liquid xenon within the same experimental apparatus was comparable
Calibration of liquid argon and neon detectors with
We report results from tests of Kr, as a calibration
source in liquid argon and liquid neon. Kr atoms are
produced in the decay of Rb, and a clear Kr
scintillation peak at 41.5 keV appears in both liquids when filling our
detector through a piece of zeolite coated with Rb. Based on this
scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a
resolution of 6% (/E) and 3.0 photoelectrons/keV in liquid neon with a
resolution of 19% (/E). The observed peak intensity subsequently decays
with the Kr half-life after stopping the fill, and we
find evidence that the spatial location of Kr atoms in
the chamber can be resolved. Kr will be a useful
calibration source for liquid argon and neon dark matter and solar neutrino
detectors.Comment: 7 pages, 12 figure
A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers
We report the testing of a charcoal-based Kr-83m source for use in
calibrating a low background two-phase liquid xenon detector. Kr-83m atoms
produced through the decay of Rb-83 are introduced into a xenon detector by
flowing xenon gas past the Rb-83 source. 9.4 keV and 32.1 keV transitions from
decaying 83Krm nuclei are detected through liquid xenon scintillation and
ionization. The characteristics of the Kr-83m source are analyzed and shown to
be appropriate for a low background liquid xenon detector. Introduction of
Kr-83m allows for quick, periodic calibration of low background noble liquid
detectors at low energy.Comment: Updated to version submitted to JINS
Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
We report the preparation of neutron-activated xenon for the calibration of
liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable
states, produced by fast neutron activation, were detected and their activities
measured in a LXe scintillation detector. Following a five-day activation of
natural xenon gas with a Cf-252 (4 x 10^5 n/s) source, the activities of two
gamma ray lines at 164 keV and 236 keV, from Xe-131m and Xe-129m metastable
states, were measured at about 95 and 130 Bq/kg, respectively. We also observed
three additional lines at 35 keV, 100 keV and 275 keV, which decay away within
a few days. No long-lifetime activity was observed after the neutron
activation.Comment: to be published in NIM A, corrected typos in Table 1 and Fig.6 of the
previous versio
Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber
We present a measurement of the extraction efficiency of quasi-free electrons
from the liquid into the gas phase in a two-phase xenon time-projection
chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm
in the liquid xenon, corresponding to 4.5 to 13.1 kV/cm in the gaseous xenon.
Extraction efficiency continues to increase at the highest extraction fields,
implying that additional charge signal may be attained in two-phase xenon
detectors through careful high-voltage engineering of the gate-anode region
Calibration of a Liquid Xenon Detector with Kr-83m
We report the preparation of a Kr-83m source and its subsequent use in
calibrating a liquid xenon detector. Kr-83m atoms were produced through the
decay of Rb-83 atoms trapped in zeolite molecular sieve and were then
introduced into liquid xenon. Decaying Kr-83m nuclei were detected through
liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and
32.1 keV from the decay of Kr-83m were both observed. This calibration source
will allow the characterization of the scintillation and ionization response of
noble liquid detectors at low energies, highly valuable for the search for WIMP
dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both
to understand purification in noble liquid-based particle detectors, as well as
for studies of classical and quantum turbulence in superfluid helium.Comment: Minor edits to match published versio
Operation of a high purity germanium crystal in liquid argon as a Compton suppressed radiation spectrometer
A high purity germanium crystal was operated in liquid argon as a Compton
suppressed radiation spectrometer. Spectroscopic quality resolution of less
than 1% of the full-width half maximum of full energy deposition peaks was
demonstrated. The construction of the small apparatus used to obtain these
results is reported. The design concept is to use the liquid argon bath to both
cool the germanium crystal to operating temperatures and act as a scintillating
veto. The scintillation light from the liquid argon can veto cosmic-rays,
external primordial radiation, and gamma radiation that does not fully deposit
within the germanium crystal. This technique was investigated for its potential
impact on ultra-low background gamma-ray spectroscopy. This work is based on a
concept initially developed for future germanium-based neutrinoless double-beta
decay experiments.Comment: Paper presented at the SORMA XI Conference, Ann Arbor, MI, May 200
- …