3,772 research outputs found

    Variable mixer propulsion cycle

    Get PDF
    A design technique, method and apparatus are delineated for controlling the bypass gas stream pressure and varying the bypass ratio of a mixed flow gas turbine engine in order to achieve improved performance. The disclosed embodiments each include a mixing device for combining the core and bypass gas streams. The variable area mixing device permits the static pressures of the core and bypass streams to be balanced prior to mixing at widely varying bypass stream pressure levels. The mixed flow gas turbine engine therefore operates efficiently over a wide range of bypass ratios and the dynamic pressure of the bypass stream is maintained at a level which will keep the engine inlet airflow matched to an optimum design level throughout a wide range of engine thrust settings

    Projecting prevalence by stage of care for prostate cancer and estimating future health service needs: protocol for a modelling study

    Get PDF
    Introduction Current strategies for the management of prostate cancer are inadequate in Australia. We will, in this study, estimate current service needs and project the future needs for prostate cancer patients in Australia. Methods and analysis First, we will project the future prevalence of prostate cancer for 2010-2018 using data for 1972-2008 from the New South Wales (NSW) Central Cancer Registry. These projections, based on modelled incidence and survival estimates, will be estimated using PIAMOD (Prevalence, Incidence, Analysis MODel) software. Then the total prevalence will be decomposed into five stages of care: initial care, continued monitoring, recurrence, last year of life and long-term survivor. Finally, data from the NSW Prostate Cancer Care and Outcomes Study, including data on patterns of treatment and associated quality of life, will be used to estimate the type and amount of services that will be needed by prostate cancer patients in each stage of care. In addition, Central Cancer Registry episode data will be used to estimate transition rates from localised or locally advanced prostate cancer to metastatic disease. Medicare and Pharmaceutical Benefits data, linked with Prostate Cancer Care and Outcomes Study data, will be used to complement the Cancer Registry episode data. The methods developed will be applied Australia-wide to obtain national estimates of the future prevalence of prostate cancer for different stages of clinical care. Ethics and dissemination This study was approved by the NSW Population and Health Services Research Ethics Committee. Results of the study will be disseminated widely to different interest groups and organisations through a report, conference presentations and peer-reviewed articles.This work is supported by the Prostate Cancer Foundation of Australia (grant number: PCFA – YI 0410). Both David Smith and Xue Qin Yu are supported by an Australian NHMRC Training Fellowship (Ref 1016598, 550002). Mark Clements is supported by an Australian NHMRC Career Development Award (Ref 471491)

    Silicon web process development

    Get PDF
    Thirty-five (35) furnace runs were carried out during this quarter, of which 25 produced a total of 120 web crystals. The two main thermal models for the dendritic growth process were completed and are being used to assist the design of the thermal geometry of the web growth apparatus. The first model, a finite element representation of the susceptor and crucible, was refined to give greater precision and resolution in the critical central region of the melt. The second thermal model, which describes the dissipation of the latent heat to generate thickness-velocity data, was completed. Dendritic web samples were fabricated into solar cells using a standard configuration and a standard process for a N(+) -P-P(+) configuration. The detailed engineering design was completed for a new dendritic web growth facility of greater width capability than previous facilities

    Low cost silicon solar array project large area silicon sheet task: Silicon web process development

    Get PDF
    Growth configurations were developed which produced crystals having low residual stress levels. The properties of a 106 mm diameter round crucible were evaluated and it was found that this design had greatly enhanced temperature fluctuations arising from convection in the melt. Thermal modeling efforts were directed to developing finite element models of the 106 mm round crucible and an elongated susceptor/crucible configuration. Also, the thermal model for the heat loss modes from the dendritic web was examined for guidance in reducing the thermal stress in the web. An economic analysis was prepared to evaluate the silicon web process in relation to price goals

    Large-area sheet task advanced dendritic web growth development

    Get PDF
    The computer code for calculating web temperature distribution was expanded to provide a graphics output in addition to numerical and punch card output. The new code was used to examine various modifications of the J419 configuration and, on the basis of the results, a new growth geometry was designed. Additionally, several mathematically defined temperature profiles were evaluated for the effects of the free boundary (growth front) on the thermal stress generation. Experimental growth runs were made with modified J419 configurations to complement the modeling work. A modified J435 configuration was evaluated

    Large area sheet task: Advanced dendritic web growth development

    Get PDF
    The growth of silicon dendritic web for photovoltaic applications was investigated. The application of a thermal model for calculating buckling stresses as a function of temperature profile in the web is discussed. Lid and shield concepts were evaluated to provide the data base for enhancing growth velocity. An experimental web growth machine which embodies in one unit the mechanical and electronic features developed in previous work was developed. In addition, evaluation of a melt level control system was begun, along with preliminary tests of an elongated crucible design. The economic analysis was also updated to incorporate some minor cost changes. The initial applications of the thermal model to a specific configuration gave results consistent with experimental observation in terms of the initiation of buckling vs. width for a given crystal thickness

    Tuning Magnetic Avalanches in Mn12-ac

    Full text link
    Using micron-sized Hall sensor arrays to obtain time-resolved measurements of the local magnetization, we report a systematic study in the molecular magnet Mn12_{12}-acetate of magnetic avalanches controllably triggered in different fixed external magnetic fields and for different values of the initial magnetization. The speeds of propagation of the spin-reversal fronts are in good overall agreement with the theory of magnetic deflagration of Garanin and Chudnovsky \cite{Garanin}.Comment: 8 pages, 7 figures; discussion expanded and revise

    A study of blood contamination of Siqveland matrix bands

    Get PDF
    AIMS To use a sensitive forensic test to measure blood contamination of used Siqveland matrix bands following routine cleaning and sterilisation procedures in general dental practice. MATERIALS AND METHODS: Sixteen general dental practices in the West of Scotland participated. Details of instrument cleaning procedures were recorded for each practice. A total of 133 Siqveland matrix bands were recovered following cleaning and sterilisation and were examined for residual blood contamination by the Kastle-Meyer test, a well-recognised forensic technique. RESULTS: Ultrasonic baths were used for the cleaning of 62 (47%) bands and retainers and the remainder (53%) were hand scrubbed prior to autoclaving. Overall, 21% of the matrix bands and 19% of the retainers gave a positive Kastle-Meyer test, indicative of residual blood contamination, following cleaning and sterilisation. In relation to cleaning method, 34% of hand-scrubbed bands and 32% of hand-scrubbed retainers were positive for residual blood by the Kastle-Meyer test compared with 6% and 3% respectively of ultrasonically cleaned bands and retainers (P less than 0.001). CONCLUSIONS: If Siqveland matrix bands are re-processed in the assembled state, then adequate pre-sterilisation cleaning cannot be achieved reliably. Ultrasonic baths are significantly more effective than hand cleaning for these items of equipment
    • …
    corecore