1,799 research outputs found

    Shuttle active thermal control system development testing. Volume 6: Water ejector plume tests

    Get PDF
    Results are given of vacuum testing of nozzles designed to eject water vapor away from the space shuttle to prevent contamination of the spacecraft surfaces and payload. The water vapor is generated by an active cooling system which evaporates excess fuel cell water to supplement a modular radiator system (MRS). The complete heat rejection system including the MRS, flash evaporator or sublimator and nozzle were first tested to demonstrate the system operational characteristics. The plume tests were performed in two phases and the objectives of this test series were: (1) to determine the effectiveness of a supersonic nozzle and a plugged nozzle in minimizing impingement upon the spacecraft of water vapor exhausted by an active device (flash evaporator or sublimator); and (2) to obtain basic data on the flow fields of exhaust plumes generated by these active devices, both with and without nozzles installed

    Mammalian oocytes are targets for prostaglandin E2 (PGE2) action

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The ovulatory gonadotropin surge increases synthesis of prostaglandin E2 (PGE2) by the periovulatory follicle. PGE2 actions on granulosa cells are essential for successful ovulation. The aim of the present study is to determine if PGE2 also acts directly at the oocyte to regulate periovulatory events.</p> <p>Methods</p> <p>Oocytes were obtained from monkeys and mice after ovarian follicular stimulation and assessed for PGE2 receptor mRNA and proteins. Oocytes were cultured with vehicle or PGE2 and assessed for cAMP generation, resumption of meiosis, and in vitro fertilization.</p> <p>Results</p> <p>Germinal vesicle intact (GV) oocytes from both monkeys and mice expressed mRNA for the PGE2 receptors EP2, EP3, and EP4. EP2 and EP4 proteins were detected by confocal microscopy in oocytes of both species. Monkey and mouse oocytes responded to PGE2 as well as agonists selective for EP2 and EP4 receptors with elevated cAMP, consistent with previous identification of EP2 and EP4 as Gαs/adenylyl cyclase coupled receptors. Incubation of mouse GV stage oocytes with PGE2 delayed oocyte nuclear maturation in vitro, but PGE2 treatment did not alter the percentage of mouse oocytes that fertilized successfully. PGE2 treatment also decreased the percentage of monkey oocytes that resumed meiosis in vitro. In contrast with mouse oocytes, the percentage of monkey oocytes which fertilized in vitro was lower after treatment with PGE2. Monkey oocytes with intact cumulus showed delayed nuclear maturation, but fertilization rate was not affected by PGE2 treatment.</p> <p>Conclusions</p> <p>Monkey and mouse oocytes express functional PGE2 receptors. PGE2 acts directly at mammalian oocytes to delay nuclear maturation. Surrounding cumulus cells modulate the effect of PGE2 to alter subsequent fertilization.</p

    Psychometric Characteristics of the Connor-Davidson Resilience Scale (CD-RISC) in Postpartum Mothers with Histories of Childhood Maltreatment

    Get PDF
    Background: There is increased awareness that resilience serves as a protective factor against adverse psychophysiological sequelae in the context of stress. However, there are few instruments to assess this construct in adult populations. The Connor-Davidson resilience scale (CD-RISC) has been developed to assess adaptation following stress exposure. While this instrument has previously demonstrated impressive reliability and construct validity, prior research has not supported the consistency of the originally described factor structure. There is also limited evidence regarding the measurement of resilience in the context of cumulative stress exposure. Objectives: This research explores the psychometric properties of the CD-RISC in mothers with childhood histories of maltreatment Materials and Methods: Postpartum women who endorsed a history of childhood abuse or neglect (N = 141) completed the CD-RISC, the childhood trauma questionnaire and other surveys measuring positive and negative health and functioning. We calculated descriptive statistics with percentage counts and means as appropriate. Internal reliability was evaluated by Cronbach’s alpha and the calculation of item-to-total score correlations. Parallel analysis (PA) was utilized to derive the number of retained factors. Results: A recent parenting transition concomitant with a history of maltreatment was associated with lower CD-RISC scores. Internal reliability and concurrent validity analyses were satisfactory and consistent with predicted hypotheses. Exploratory factor analysis (EFA) supported a four-factor model of resilience with this population. Conclusions: This research offers further evidence of the reliability and validity of the CD-RISC. Further, the results of the EFA with parallel analysis offer an empirically-driven derivation of factors for this population

    Aquatic Eddy Correlation: Quantifying the Artificial Flux Caused by Stirring-Sensitive O2 Sensors

    Get PDF
    In the last decade, the aquatic eddy correlation (EC) technique has proven to be a powerful approach for non-invasive measurements of oxygen fluxes across the sediment water interface. Fundamental to the EC approach is the correlation of turbulent velocity and oxygen concentration fluctuations measured with high frequencies in the same sampling volume. Oxygen concentrations are commonly measured with fast responding electrochemical microsensors. However, due to their own oxygen consumption, electrochemical microsensors are sensitive to changes of the diffusive boundary layer surrounding the probe and thus to changes in the ambient flow velocity. The so-called stirring sensitivity of microsensors constitutes an inherent correlation of flow velocity and oxygen sensing and thus an artificial flux which can confound the benthic flux determination. To assess the artificial flux we measured the correlation between the turbulent flow velocity and the signal of oxygen microsensors in a sealed annular flume without any oxygen sinks and sources. Experiments revealed significant correlations, even for sensors designed to have low stirring sensitivities of ~0.7%. The artificial fluxes depended on ambient flow conditions and, counter intuitively, increased at higher velocities because of the nonlinear contribution of turbulent velocity fluctuations. The measured artificial fluxes ranged from 2-70 mmol m(-2) d(-1) for weak and very strong turbulent flow, respectively. Further, the stirring sensitivity depended on the sensor orientation towards the flow. For a sensor orientation typically used in field studies, the artificial flux could be predicted using a simplified mathematical model. Optical microsensors (optodes) that should not exhibit a stirring sensitivity were tested in parallel and did not show any significant correlation between O2 signals and turbulent flow. In conclusion, EC data obtained with electrochemical sensors can be affected by artificial flux and we recommend using optical microsensors in future EC-studies

    Quantitative changes in intracellular calcium and extracellular-regulated kinase activation measured in parallel in CHO cells stably expressing serotonin (5-HT) 5-HT2A or 5-HT2C receptors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The serotonin (5-HT) 2A and 2C receptors (5-HT<sub>2A</sub>R and 5-HT<sub>2C</sub>R) are involved in a wide range of physiological and behavioral processes in the mammalian central and peripheral nervous systems. These receptors share a high degree of homology, have overlapping pharmacological profiles, and utilize many of the same and richly diverse second messenger signaling systems. We have developed quantitative assays for cells stably expressing these two receptors involving minimal cell sample manipulations that dramatically improve parallel assessments of two signaling responses: intracellular calcium (<it>Ca<sub>i</sub></it><sup>++</sup>) changes and activation (phosphorylation) of downstream kinases. Such profiles are needed to begin to understand the simultaneous contributions from the multiplicity of signaling cascades likely to be initiated by serotonergic ligands.</p> <p>Results</p> <p>We optimized the <it>Ca<sub>i</sub></it><sup>++ </sup>assay for stable cell lines expressing either 5-HT<sub>2A</sub>R or 5-HT<sub>2C</sub>R (including dye use and measurement parameters; cell density and serum requirements). We adapted a quantitative 96-well plate immunoassay for pERK in the same cell lines. Similar cell density optima and time courses were observed for 5-HT<sub>2A</sub>R- and 5-HT<sub>2C</sub>R-expressing cells in generating both types of signaling. Both cell lines also require serum-free preincubation for maximal agonist responses in the pERK assay. However, 5-HT<sub>2A</sub>R-expressing cells showed significant release of <it>Ca<sub>i</sub></it><sup>++ </sup>in response to 5-HT stimulation even when preincubated in serum-replete medium, while the response was completely eliminated by serum in 5-HT<sub>2C</sub>R-expressing cells. Response to another serotonergic ligand (DOI) was eliminated by serum-replete preincubation in both cells lines.</p> <p>Conclusions</p> <p>These data expand our knowledge of differences in ligand-stimulated signaling cascades between 5-HT<sub>2A</sub>R and 5-HT<sub>2C</sub>R. Our parallel assays can be applied to other cell and receptor systems for monitoring and dissecting concurrent signaling responses.</p

    An assessment of the precision and confidence of aquatic eddy correlation measurements

    Get PDF
    The quantification of benthic fluxes with the aquatic eddy correlation (EC) technique is based on simultaneous measurement of the current velocity and a targeted bottom water parameter (e. g., O-2, temperature). High-frequency measurements (64Hz) are performed at a single point above the seafloor using an acoustic Doppler velocimeter (ADV) and a fast-responding sensor. The advantages of aquatic EC technique are that 1) it is noninvasive, 2) it integrates fluxes over a large area, and 3) it accounts for in situ hydrodynamics. The aquatic EC has gained acceptance as a powerful technique; however, an accurate assessment of the errors introduced by the spatial alignment of velocity and water constituent measurements and by their different response times is still needed. Here, this paper discusses uncertainties and biases in the data treatment based on oxygen EC flux measurements in a large-scale flume facility with well-constrained hydrodynamics. These observations are used to review data processing procedures and to recommend improved deployment methods, thus improving the precision, reliability, and confidence of EC measurements. Specifically, this study demonstrates that 1) the alignment of the time series based on maximum cross correlation improved the precision of EC flux estimations; 2) an oxygen sensor with a response time of <0.4 s facilitates accurate EC fluxes estimates in turbulence regimes corresponding to horizontal velocities <11 cm s(-1); and 3) the smallest possible distance (<1 cm) between the oxygen sensor and the ADV's sampling volume is important for accurate EC flux estimates, especially when the flow direction is perpendicular to the sensor's orientation

    QuShape: Rapid, accurate, and best-practices quantification of nucleic acid probing information, resolved by capillary electrophoresis

    Get PDF
    Chemical probing of RNA and DNA structure is a widely used and highly informative approach for examining nucleic acid structure and for evaluating interactions with protein and small-molecule ligands. Use of capillary electrophoresis to analyze chemical probing experiments yields hundreds of nucleotides of information per experiment and can be performed on automated instruments. Extraction of the information from capillary electrophoresis electropherograms is a computationally intensive multistep analytical process, and no current software provides rapid, automated, and accurate data analysis. To overcome this bottleneck, we developed a platform-independent, user-friendly software package, QuShape, that yields quantitatively accurate nucleotide reactivity information with minimal user supervision. QuShape incorporates newly developed algorithms for signal decay correction, alignment of time-varying signals within and across capillaries and relative to the RNA nucleotide sequence, and signal scaling across channels or experiments. An analysis-by-reference option enables multiple, related experiments to be fully analyzed in minutes. We illustrate the usefulness and robustness of QuShape by analysis of RNA SHAPE (selective 2′-hydroxyl acylation analyzed by primer extension) experiments

    Comparing bladder neck contracture rate between robotic intracorporeal and extracorporeal neobladder construction

    Get PDF
    Robot-assisted radical cystectomy (RARC) has become more accessible to surgeons worldwide, and descriptions of intracorporeal urinary diversion techniques, such as orthotopic neobladder construction, have increased. In this study, we aim to compare the rate of bladder neck contracture (BNC) formation between RARC and two different urinary diversion techniques. We retrospectively reviewed our institutional database for patients with bladder cancer who underwent RARC with intracorporeal neobladder (ICNB) construction (n = 11) or extracorporeal neobladder (ECNB) construction (n = 11) between 2012 and 2020. BNC was defined by the need for an additional surgical procedure (e.g., dilatation, urethrotomy). Patients who underwent RARC with ICNB (n = 11) were compared to patients who underwent RARC with ECNB (n = 11) across patient characteristics and postoperative BNC formation rates. Kaplan-Meier curves were generated for freedom from BNC based on the neobladder approach and compared with the log-rank test. For patients who received an ECNB, 73% (8/11) developed a BNC; in comparison, none of the patients in the ICNB group experienced a BNC. Kaplan-Meier survival analysis demonstrates the ECNB group\u27s median probability of freedom from BNC as 1.3 years, while the ICNB group was free of BNC over the study period (p \u3c 0.001). RARC with ICNB creation demonstrated a significantly reduced BNC rate in contrast to RARC with ECNB construction. Longer-term follow-up is needed to assess the durability of this difference in BNC rates
    corecore