6,621 research outputs found

    Polarized Diffuse Emission at 2.3 GHz in a High Galactic Latitude Area

    Full text link
    Polarized diffuse emission observations at 2.3 GHz in a high Galactic latitude area are presented. The 2\degr X 2\degr field, centred in (\alpha=5^h,\delta=-49\degr), is located in the region observed by the BOOMERanG experiment. Our observations has been carried out with the Parkes Radio telescope and represent the highest frequency detection done to date in low emission areas. Because of a weaker Faraday rotation action, the high frequency allows an estimate of the Galactic synchrotron contamination of the Cosmic Microwave Background Polarization (CMBP) that is more reliable than that done at 1.4 GHz. We find that the angular power spectra of the E- and B-modes have slopes of \beta_E = -1.46 +/- 0.14 and \beta_B = -1.87 +/- 0.22, indicating a flattening with respect to 1.4 GHz. Extrapolated up to 32 GHz, the E-mode spectrum is about 3 orders of magnitude lower than that of the CMBP, allowing a clean detection even at this frequency. The best improvement concerns the B-mode, for which our single-dish observations provide the first estimate of the contamination on angular scales close to the CMBP peak (about 2 degrees). We find that the CMBP B-mode should be stronger than synchrotron contamination at 90 GHz for models with T/S > 0.01. This low level could move down to 60-70 GHz the optimal window for CMBP measures.Comment: 5 pages, 6 figures, accepted for publication in MNRAS Letter

    Soluble CD40 ligand can replace the normal T cell-derived CD40 ligand signal to B cells in T cell-dependent activation

    Get PDF
    We have constructed a soluble chimeric fusion protein between the mouse CD8 alpha chain and the mouse CD40 T cell ligand. This protein binds to both human and mouse B cells. By itself it induced a modest degree of B cell proliferation, but together with anti-immunoglobulin (anti-Ig) antibody it greatly stimulated B cell proliferation, as determined by both [3H]thymidine uptake and increase in cell numbers. These data are evidence that the CD40 ligand on T cells provides a signal that drives B cell proliferation. This signal is synergistic with that delivered by anti-Ig antibody

    The colon as a target for vaccination: quantification of lymphoid tissue in mouse colon prior to vaccination

    Get PDF
    Currently, most vaccines are given by injection. However, due to the inherent problems associated with injections, other routes of drug delivery are being researched, among them, the oral route. So far, research into oral vaccination has not differentiated between vaccine uptake by the different parts of the gastro-intestinal tract, such as the small and large intestine. It is likely that following oral vaccine administration, the vaccine is mostly taken up by the lymphoid tissue of the small intestine

    SONTRAC: an imaging spectrometer for solar neutrons

    Get PDF
    An instrument capable of unambiguously determining the energy and direction of incident neutrons has important applications in solar physics-as well as environmental monitoring and medical/radiological sciences. The SONTRAC (SOlar Neutron TRACking) instrument is designed to operate in the neutron energy range of 20-250 MeV. The measurement principle is based on non-relativistic double scatter of neutrons off ambient protons (n-p scattering) within a block of densely packed scintillating fibers. Using this double-scatter mode it is possible to uniquely determine neutron energy and direction on an event-by-event basis. A fully operational science model of such an instrument has been built using 300 μm (250 μm active) scintillating fibers. The science model consists of a 5×5×5 cm cube of orthogonal plastic scintillating fiber layers. Two orthogonal imaging chains, employing image intensifiers and CCD cameras, allow full 3-dimensional reconstruction of scattered proton particle tracks. We report the results of the science model instrument calibration using 35-65 MeV protons. The proton calibration is the first step toward understanding the instrument response to n-p scatter events. Preliminary results give proton energy resolution of 2% (6%) at 67.5 (35) MeV, and angular resolution of 2° (4.5°) at 67.5 (35) MeV. These measurements are being used to validate detailed instrument simulations that will be used to optimize the instrument design and develop quantitative estimates of science return. Based on the proton calibration, neutron energy and angular resolution for a 10×10×10 cm version of SONTRAC is expected to be ~5% an

    The Effect of Spatial Gradients in Stellar Mass-to-Light Ratio on Black Hole Mass Measurements

    Get PDF
    We have tested the effect of spatial gradients in stellar mass-to-light ratio (Y) on measurements of black hole masses (MBH) derived from stellar orbit superposition models. Such models construct a static gravitational potential for a galaxy and its central black hole, but typically assume spatially uniform Y. We have modeled three giant elliptical galaxies with gradients alpha = d(log Y)/d(log r) from -0.2 to +0.1. Color and line strength gradients suggest mildly negative alpha in these galaxies. Introducing a negative (positive) gradient in Y increases (decreases) the enclosed stellar mass near the center of the galaxy and leads to systematically smaller (larger) MBH measurements. For models with alpha = -0.2, the best-fit values of MBH are 28%, 27%, and 17% lower than the constant-Y case, in NGC 3842, NGC 6086, and NGC 7768, respectively. For alpha = +0.1, MBH are 14%, 22%, and 17% higher than the constant-Y case for the three respective galaxies. For NGC 3842 and NGC 6086, this bias is comparable to the statistical errors from individual modeling trials. At larger radii, negative (positive) gradients in Y cause the total stellar mass to decrease (increase) and the dark matter fraction within one effective radius to increase (decrease).Comment: 6 pages, 4 figures, 1 table. To appear in ApJ

    Development and performance of the Fast Neutron Imaging Telescope for SNM detection

    Get PDF
    FNIT (the Fast Neutron Imaging Telescope), a detector with both imaging and energy measurement capabilities, sensitive to neutrons in the range 0.8-20 MeV, was initially conceived to study solar neutrons as a candidate design for the Inner Heliosphere Sentinel (IHS) spacecraft of NASA\u27s Solar Sentinels program and successively reconfigured to locate fission neutron sources. By accurately identifying the position of the source with imaging techniques and reconstructing the Watt spectrum of fission neutrons, FNIT can detect samples of special nuclear material (SNM), including heavily shielded and masked ones. The detection principle is based on multiple elastic neutron-proton scatterings in organic scintillators. By reconstructing n-p event locations and sequence and measuring the recoil proton energies, the direction and energy spectrum of the primary neutron flux can be determined and neutron sources identified. We describe the design of the FNIT prototype and present its energy reconstruction and imaging performance, assessed by exposing FNIT to a neutron beam and to a Pu fission neutron source

    ‘‘There’s so much more to it than what I initially thought’’: Stepping into researchers’ shoes with a class activity in a first year psychology survey course

    Get PDF
    In psychology, it is widely agreed that research methods, although central to the discipline, are particularly challenging to learn and teach, particularly at introductory level. This pilot study explored the potential of embedding a student-conducted research activity in a one-semester undergraduate Introduction to Psychology survey course, with the aims of (a) engaging students with the topic of research methods; (b) developing students’ comprehension and application of research methods concepts; and (c) building students’ ability to link research with theory. The research activity explored shoe ownership, examining gender differences and relationships with age, and linking to theories of gender difference and of consumer identity. The process of carrying out the research and reflecting on it created a contextualized, active learning environment in which students themselves raised many issues that research methods lectures seek to cover. Students also wrote richer assignments than standard first year mid-term essay

    Rotational Brownian motion on the sphere surface and rotational relaxation

    Full text link
    The spatial components of the autocorrelation function of noninteracting dipoles are analytically obtained in terms of rotational Brownian motion on the surface of a unit sphere using multi-level jumping formalism based on Debye's rotational relaxation model, and the rotational relaxation functions are evaluated.Comment: RevTex, 4 pages, submitted to Chin. Phys. Let

    Stability analysis of polarized domains

    Full text link
    Polarized ferrofluids, lipid monolayers and magnetic bubbles form domains with deformable boundaries. Stability analysis of these domains depends on a family of nontrivial integrals. We present a closed form evaluation of these integrals as a combination of Legendre functions. This result allows exact and explicit formulae for stability thresholds and growth rates of individual modes. We also evaluate asymptotic behavior in several interesting limits.Comment: 12 pages, 3 figures, Late

    Advanced characterization and simulation of SONNE: a fast neutron spectrometer for Solar Probe Plus

    Get PDF
    SONNE, the SOlar NeutroN Experiment proposed for Solar Probe Plus, is designed to measure solar neutrons from 1-20 MeV and solar gammas from 0.5-10 MeV. SONNE is a double scatter instrument that employs imaging to maximize its signal-to-noise ratio by rejecting neutral particles from non-solar directions. Under the assumption of quiescent or episodic small-flare activity, one can constrain the energy content and power dissipation by fast ions in the low corona. Although the spectrum of protons and ions produced by nanoflaring activity is unknown, we estimate the signal in neutrons and γ−rays that would be present within thirty solar radii, constrained by earlier measurements at 1 AU. Laboratory results and simulations will be presented illustrating the instrument sensitivity and resolving power
    corecore