1,485 research outputs found

    Fast flow microfluidics and single-molecule fluorescence for the rapid characterization of α-synuclein oligomers.

    Get PDF
    α-Synuclein oligomers can be toxic to cells and may be responsible for cell death in Parkinson's disease. Their typically low abundance and highly heterogeneous nature, however, make such species challenging to study using traditional biochemical techniques. By combining fast-flow microfluidics with single-molecule fluorescence, we are able to rapidly follow the process by which oligomers of αS are formed and to characterize the species themselves. We have used the technique to show that populations of oligomers with different FRET efficiencies have varying stabilities when diluted into low ionic strength solutions. Interestingly, we have found that oligomers formed early in the aggregation pathway have electrostatic repulsions that are shielded in the high ionic strength buffer and therefore dissociate when diluted into lower ionic strength solutions. This property can be used to isolate different structural groups of αS oligomers and can help to rationalize some aspects of αS amyloid fibril formation.M.H.H. thanks the Royal Society of Chemistry (Analytical Chemistry Trust Fund) for his studentship. L.T. has been the recipient of a grant PAT Post Doc Outgoing 2009 – 7th Framework Program Marie Curie COFUND actions. A.J.D. is funded by the Schiff Foundation.This is the author accepted manuscript. The final version is available from ACS via http://dx.doi.org/10.1021/acs.analchem.5b0181

    An aortic aneurysm model for the evaluation of endovascular exclusion prostheses

    Get PDF
    Abstract Purpose: The purpose of this study was to develop an aortic aneurysm (AA) model with a predictable tendency for rupture for the evaluation of the efficacy of endovascular prostheses in preventing rupture and their long-term outcome after implantation. Methods: An infrarenal AA measuring two to three times the diameter of the proximal aorta was created in 18 dogs with a full-thickness patch of jejunum. Seven dogs were allowed to survive without aneurysm exclusion. In 11 dogs the aneurysm was immediately excluded with a stented 8 mm Dacron graft mounted in a 14F delivery system introduced through the femoral artery with aortographic guidance. The pressure differential between the aorta and the excluded aneurysm was measured, and angiography, necropsy, and histologic examination were performed at 3- and 6-month survival. Results: All animals survived aneurysm implantation. Without aneurysm exclusion, six dogs died of rupture within 1 to 6 days of surgery. In three dogs the exclusion failed because of graft-to-aorta size mismatch or misplacement demonstrated on angiography and by a low pressure differential between the aorta and the aneurysm (p < 0.023) in dogs with successfully excluded aneurysms (n = 6) compared with that in dogs without exclusion or with failed aneurysm exclusion (n = 7). Conclusion: This aneurysm model demonstrates that without effective aneurysm exclusion all animals die of rupture and that successfully placed endovascular prostheses can prevent AA rupture with long-term graft patency and stability. Endovascular aortic Dacron grafts in dogs undergo complete incorporation at 3 months from implantation. This aneurysm model is useful for the evaluation of endovascular devices designed for the treatment of AAs. (J VASC SURG 1995;22:306-15.

    Decellularised skeletal muscles allow functional muscle regeneration by promoting host cell migration

    Get PDF
    Pathological conditions affecting skeletal muscle function may lead to irreversible volumetric muscle loss (VML). Therapeutic approaches involving acellular matrices represent an emerging and promising strategy to promote regeneration of skeletal muscle following injury. Here we investigated the ability of three different decellularised skeletal muscle scaffolds to support muscle regeneration in a xenogeneic immune-competent model of VML, in which the EDL muscle was surgically resected. All implanted acellular matrices, used to replace the resected muscles, were able to generate functional artificial muscles by promoting host myogenic cell migration and differentiation, as well as nervous fibres, vascular networks, and satellite cell (SC) homing. However, acellular tissue mainly composed of extracellular matrix (ECM) allowed better myofibre three-dimensional (3D) organization and the restoration of SC pool, when compared to scaffolds which also preserved muscular cytoskeletal structures. Finally, we showed that fibroblasts are indispensable to promote efficient migration and myogenesis by muscle stem cells across the scaffolds in vitro. This data strongly support the use of xenogeneic acellular muscles as device to treat VML conditions in absence of donor cell implementation, as well as in vitro model for studying cell interplay during myogenesis

    US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report

    Get PDF
    This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.Comment: 102 pages + reference

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file
    corecore