987 research outputs found

    Recycling of Wastes Deriving from the Production of Epoxy-Carbon Fiber Composites in the Production of Polymer Composites

    Get PDF
    The formulation of composites reinforced with shredded epoxy-carbon fibers wastes is investigated. Poly (buthylene terephthalate) PBT was selected as the matrix for the composites. In order to increase the interaction between the epoxy resin still coating the carbon fibers and the PBT matrix, polycarbonate (PC) was added either to the matrix formulation or as a waste coating. The flexural strength, impact strength, and dynamic-mechanical analysis of the new composites was investigated, as well as their microstructure by scanning electron microscopy. Experimental results show that the recycled fibers can be dispersed in both pure PBT and in its blend, enhancing the mechanical properties of the composites. An increase in the investigated properties is found specifically in the elastic modulus below 50 degrees C and in the impact strength. The extent of the increase depends on the obtained microstructure

    Effects of short‐loop material recycling on mechanical properties of parts by Arburg Plastic Freeforming

    Get PDF
    Arburg Plastic Freeforming allows for transforming granulated thermoplastics with variable shapes and sizes. This opens marvellous opportunities for in-place recycling of process waste and auxiliary structures. The present study investigates for the first time the effects of recycled material on the mechanical properties of manufactured parts. To this end, the mechanical, thermomechanical and rheological properties of parts produced with different contents of recycled material are investigated. Findings demonstrate that a balanced mixture of primary and secondary material determines a drop in mechanical performances due to a less accurate deposition. A higher percentage of recycled material determines a sharp decrease in viscosity, leading to a more homogeneous layer and tensile properties similar to those of the virgin polymer. The drop in viscosity also affects the accuracy of deposition, determining a worse definition of sharp edges

    Environmental drawbacks of lightweight design algorithms in material extrusion additive manufacturing: a case study

    Get PDF
    Lightweight design is often assumed to be the leading strategy to improve the sustainability of parts produced by additive manufacturing. The present study confutes such an assumption by a cradle-to-gate life cycle assessment of different lightweight strategies applied to a specific case study in the medical field. In particular, a patient-specific finger splint made of polyamide is redesigned by means of generative design, topology optimization and lattice structures. The analysis investigates two markedly different deposition processes, namely Arburg plastic freeforming and fused filament fabrication. The former is carried out on an industrial-grade machine, while a desktop printer is used for the latter. This allows for observing the impact of the redesign in two quite distinct scenarios. Findings demonstrate that, since environmental impacts are mainly driven by building time, the adoption of automated design algorithms can be detrimental to the sustainability of the process. On the other hand, relevant benefits on environmental impacts were achieved by reducing the infill percentage of parts. The results of this work highlight the most relevant aspects which must be considered to limit environmental impacts when designing parts for deposition-based additive manufacturing. This information can be used by designers to drive weight reduction towards sustainability

    Experimental flight testing of night vision imaging systems in military fighter aircraft

    Get PDF
    This paper describes the research and experimental flight test activities conducted by the Italian Air Force Official Test Centre (RSV), in collaboration with Alenia Aermacchi and Cranfield University, in order to confer night vision imaging systems (NVIS) capability to the Italian TORNADO Interdiction and Strike and Electronic Combat and Reconnaissance aircraft. The activities included design, development, test, and evaluation activities, including night vision goggle (NVG) integration, cockpit instruments, and external lighting modifications, as well as various ground test sessions and a total of 18 flight test sorties. RSV and Litton Precision Products were responsible for coordinating and conducting the installation of the internal and external lights. Particularly, an iterative process was established allowing in-site rapid correction of the major deficiencies encountered during the ground and flight test sessions. Both single-ship (day/night) and formation (night) flights were performed, with testing activities shared among the test crews involved, allowing for a redundant examination of the various test items by all participants. An innovative test matrix was developed and implemented by RSV for assessing the operational suitability and effectiveness of the various modifications implemented. Also important was the definition of test criteria for Pilot and Weapon Systems Officer workload assessment during the accomplishment of various operational tasks during NVG missions. Furthermore, the specific technical and operational elements required for evaluating the modified helmets were identified, allowing an exhaustive comparative evaluation of the two proposed solutions (i.e., HGU-55P and HGU-55G modified helmets). The initial compatibility problems encountered were progressively mitigated by incorporating modifications in both front and rear cockpits at various stages of the test campaign. This process allowed considerable enhancement of the TORNADO NVIS configuration, giving good medium- to high-level NVG operational capability to the aircraft. Further developments also include the internal/external lighting for the Italian TORNADO “Mid-Life Update” and other programs such as AMX aircraft internal/external light modification/testing and the activities addressing low-altitude NVG operations with fast jets (e.g., TORNADO, AMX, MB-339CD), with a major issue being the safe ejection of aircrew with NVG and NVG modified helmets. Two options have been identified for solving this problem, namely, the modification of the current Gentex HGU-55 helmets and the design of a new helmet incorporating a reliable NVG connection/disconnection device (i.e., a mechanical system fully integrated in the helmet frame) with embedded automatic disconnection capability in case of ejection. Other relevant issues to be accounted for in these new developments are the helmet dimensions and weight, the NVG usable field of view as a function of eye-relief distance, and the helmet's center of gravity (moment arms) with and without NVG (effect on aircrew fatigue during training and real operational missions

    Numerical and experimental investigation of a 3D-printed PCU patient-specific cranial implant

    Get PDF
    Arburg plastic freeforming (APF) technology allows for fabricating patient-specific implants (PSIs) in a hospital environment using medical-grade thermoplastic polymers. Among these materials, poly(carbonate-urethane) (PCU) is of great relevance since it is characterised by excellent biocompatibility. This study explores the opportunity to realise a patient-specific cranial plate via APF. First, a Finite Element model (FEM) of the implant under compressive loads is developed and validated using a quasi-isotropic material. Then, this model is used for Finite Element Analysis (FEA) considering Technical Datasheet (TDS) material properties and those measured on 3D-printed specimens, by Three-Point Bending (TPB) tests. Finally, a PCU PSI is fabricated through APF and tested under static loads to validate the consistency of the numerical results. Considering TDS properties, the FEA results indicate that PCU can be used for the manufacturing of this device. Nonetheless, the TPB tests show that the material suffers from a loss of mechanical properties. Using these properties, the displacements calculated via FEA exceed the admissible values for the application. A further decrease in stiffness is observed in the manufactured plate. Overall, findings suggest that PCU can be a viable material to be printed by APF technology for fabricating craniofacial PSIs, with the advantage of minor stress concentration in critical points of the implant if compared with polyetheretheretherketone (PEEK). However, further studies are necessary to effectively represent the effects of 3D printing in the FEMs used for structural validation and design optimisatio

    Does Systematic Preliminar Colour Doppler Study Reduce Kidney Biopsy Complication Incidence?

    Get PDF
    While ultrasonography is widely performed prior to biopsy, colour Doppler examination is often used only to discover post-biopsy complications. Aim of this paper was to evaluate the usefulness of colour Doppler examination in planning the optimal site of puncture for renal biopsy. Present analysis includes 561 consecutive percutaneous renal biopsies performed from the same operator. Until August 2000 332 biopsies were performed after a preliminary ultrasonography (Group A). From September 2000, 229 patients underwent even a preliminary colour Doppler study (Group B). Postbioptic bleeding were categorized as minor (gross hematuria or subcapsular perinephric hematoma < 4 cmq of greater diameter) or major (hematoma >4 cmq of greater diameter; requiring blood transfusion or invasive procedures; leading to acute renal failure, urine tract obstruction, septicaemia, or death). Major complications were seen in 2.1% in Group A while in Group B only one case was reported (0.43%). Minor clinically significant complications occur in 7.8% in Group A and in 3.4% of cases of Group B. Colour Doppler reduced drastically the incidence of complications observed before the introduction of routine colour Doppler examination prior to biopsy. In our opinion, these data support the use of preliminary colour Doppler study when a biopsy is planned

    Role of the Adrenergic System in a Mouse Model of Oxygen-induced Retinopathy: Antiangiogenic Effects of Beta-adrenoreceptor Blockade

    Get PDF
    METHODS. Propranolol was administered subcutaneously and picropodophyllin (PPP) intraperitoneally. Intravitreal injections of vascular endothelial growth factor (VEGF) were performed. Messengers of -ARs, VEGF, its receptors, IGF-1 and IGF-1R were measured with quantitative RT-PCR. VEGF content was determined with ELISA. -ARs, hypoxia-inducible factor (HIF)-1 , occludin, and albumin were measured with Western blot. Retinal localization of 3-ARs was determined by immunohistochemistry. Retinopathy was assessed by scoring fluorescein-perfused retinas, and plasma extravasation was visualized by Evans blue dye

    Muonic atom X-ray spectroscopy for non-destructive analysis of archeological samples

    Get PDF
    The implementation in the RIKEN-RAL negative muons facility of a new muon beamline monitoring and novel digital data acquisition system for gamma and X-ray spectroscopy are presented. This work also shows the high potential of the muonic atoms X-ray spectroscopy technique in non-destructive elemental characterization of archaeological samples

    Creatine kinase and progression rate in amyotrophic lateral sclerosis

    Get PDF
    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease with no recognized clinical prognostic factor. Creatinine kinase (CK) increase in these patients is already described with conflicting results on prognosis and survival. In 126 ALS patients who were fast or slow disease progressors, CK levels were assayed for 16 months every 4 months in an observational case-control cohort study with prospective data collection conducted in Italy. CK was also measured at baseline in 88 CIDP patients with secondary axonal damage and in two mouse strains (129SvHSD and C57-BL) carrying the same SOD1G93A transgene expression but showing a fast (129Sv-SOD1G93A) and slow (C57-SOD1G93A) ALS progression rate. Higher CK was found in ALS slow progressors compared to fast progressors in T1, T2, T3, and T4, with a correlation with Revised Amyotrophic Lateral Sclerosis Functional Rating Scale (ALSFRS-R) scores. Higher CK was found in spinal compared to bulbar-onset patients. Transgenic and non-transgenic C57BL mice showed higher CK levels compared to 129SvHSD strain. At baseline mean CK was higher in ALS compared to CIDP. CK can predict the disease progression, with slow progressors associated with higher levels and fast progressors to lower levels, in both ALS patients and mice. CK is higher in ALS patients compared to patients with CIDP with secondary axonal damage; the higher levels of CK in slow progressors patients, but also in C57BL transgenic and non-transgenic mice designs CK as a predisposing factor for disease rate progression

    Biochemical and neuropathological findings in a Creutzfeldt-Jakob Disease patient with the rare Val180Ile-129Val haplotype in the prion protein gene

    Get PDF
    Genetic Creutzfeldt-Jakob disease (gCJD) associated with the V180I mutation in the prion protein (PrP) gene (PRNP) in phase with residue 129M is the most frequent cause of gCJD in East Asia, whereas it is quite uncommon in Caucasians. We report on a gCJD patient with the rare V180I-129V haplotype, showing an unusually long duration of the disease and a characteristic pathological PrP (PrPSc) glycotype. Family members carrying the mutation were fully asymptomatic, as commonly observed with this mutation. Neuropathological examination showed a lesion pattern corresponding to that commonly reported in Japanese V180I cases with vacuolization and gliosis of the cerebral cortexes, olfactory areas, hippocampus and amygdala. PrP was deposited with a punctate, synaptic-like pattern in the cerebral cortex, amygdala and olfactory tract. Western blot analyses of proteinase-K-resistant PrP showed the characteristic two-banding pattern of V180I gCJD, composed of mono- and un-glycosylated isoforms. In line with reports on other V180I cases in the literature, Real-Time Quaking Induced Conversion (RT-QuIC) analyses did not demonstrate the presence of seeding activity in the cerebrospinal fluid and olfactory mucosa, suggesting that this haplotype also may result in a reduced seeding efficiency of the pathological PrP. Further studies are required to understand the origin, penetrance, disease phenotype and transmissibility of 180I-129V haplotype in Caucasians
    corecore