259 research outputs found

    Thrombolyse der Arteria cerebri media

    Get PDF
    Zusammenfassung: In den ersten 3h nach Eintritt eines akuten ischämischen Hirninfarkts ist die intravenöse Thrombolyse (IVT) die evidenzbasierte Therapie (IVT 3-4,5h: "off-label use" mit Einverständnis des Patienten). Die intraarterielle Thrombolyse (IAT) führt in der A.cerebri media (ACM) allerdings häufiger zur Rekanalisation als die IVT. Daher ist die IAT in dafür ausgerüsteten Kliniken ergänzend oder alternativ zur IVT bis zu 6h nach Symptombeginn zu erwäge

    Experimentally realizable quantum comparison of coherent states and its applications

    Get PDF
    When comparing quantum states to each other, it is possible to obtain an unambiguous answer, indicating that the states are definitely different, already after a single measurement. In this paper we investigate comparison of coherent states, which is the simplest example of quantum state comparison for continuous variables. The method we present has a high success probability, and is experimentally feasible to realize as the only required components are beam splitters and photon detectors. An easily realizable method for quantum state comparison could be important for real applications. As examples of such applications we present a "lock and key" scheme and a simple scheme for quantum public key distribution.Comment: 14 pages, 5 figures, version one submitted to PRA. Version two is the final accepted versio

    Novel Cascaded Ultra Bright Pulsed Source of Polarization Entangled Photons

    Full text link
    A new ultra bright pulsed source of polarization entangled photons has been realized using type-II phase matching in spontaneous parametric down conversion process in two cascaded crystals. The optical axes of the crystals are aligned in such a way that the extraordinarily (ordinarily) polarized cone from one crystal overlaps with the ordinarily (extraordinarily) polarized cone from the second crystal. This spatial overlapping removes the association between the polarization and the output angle of the photons that exist in a single type-II down conversion process. Hence, entanglement of photons originating from any point on the output cones is possible if a suitable optical delay line is used. This delay line is particularly simple and easy to implement.Comment: 8 pages 8 figure

    Experimental Realization of Teleporting an Unknown Pure Quantum State via Dual Classical and Einstein-Podolski-Rosen Channels

    Get PDF
    We report on a quantum optical experimental implementation of teleportation of unknown pure quantum states. This realizes all the nonlocal aspects of the original scheme proposed by Bennett et al. and is equivalent to it up to a local operation. We exhibit results for the teleportation of a linearly polarized state and of an elliptically polarized state. We show that the experimental results cannot be explained in terms of a classical channel alone.Comment: 11 pages LaTeX, 3 figures, 1 page figures captions. The figures and figures captions are not encapsulated; please print them separatel

    Quantum state transfer and entanglement distribution among distant nodes in a quantum network

    Get PDF
    We propose a scheme to utilize photons for ideal quantum transmission between atoms located at spatially-separated nodes of a quantum network. The transmission protocol employs special laser pulses which excite an atom inside an optical cavity at the sending node so that its state is mapped into a time-symmetric photon wavepacket that will enter a cavity at the receiving node and be absorbed by an atom there with unit probability. Implementation of our scheme would enable reliable transfer or sharing of entanglement among spatially distant atoms.Comment: 4 pages, 3 postscript figure

    Trunk sway in mildly disabled multiple sclerosis patients with and without balance impairment

    Get PDF
    Multiple sclerosis (MS) causes a broad range of neurological symptoms. Most common is poor balance control. However, knowledge of deficient balance control in mildly affected MS patients who are complaining of balance impairment but have normal clinical balance tests (CBT) is limited. This knowledge might provide insights into the normal and pathophysiological mechanisms underlying stance and gait. We analysed differences in trunk sway between mildly disabled MS patients with and without subjective balance impairment (SBI), all with normal CBT. The sway was measured for a battery of stance and gait balance tests (static and dynamic posturography) and compared to that of age- and sex-matched healthy subjects. Eight of 21 patients (38%) with an Expanded Disability Status Scale of 1.0-3.0 complained of SBI during daily activities. For standing on both legs with eyes closed on a normal and on a foam surface, patients in the no SBI group showed significant differences in the range of trunk roll (lateral) sway angle and velocity, compared to normal persons. Patients in the SBI group had significantly greater lateral sway than the no SBI group, and sway was also greater than normal in the pitch (anterior-posterior) direction. Sway for one-legged stance on foam was also greater in the SBI group compared to the no SBI and normal groups. We found a specific laterally directed impairment of balance in all patients, consistent with a deficit in proprioceptive processing, which was greater in the SBI group than in the no SBI group. This finding most likely explains the subjective symptoms of imbalance in patients with MS with normal CBT

    Vascular risk factors in the Swiss population

    Get PDF
    Background and Purpose : Identification of the population at risk of stroke remains the best approach to assess the burden of cardiovascular morbidity and mortality. Methods : The prevalence of hypertension (HT), hypercholesterolemia (HCh), diabetes mellitus (DM), overweight (OW), obesity (OB), tobacco use (SM), and their combinations was examined in 4458 Swiss persons (1741 men and 2717 women, mean age 57.8 ± 15 years), who volunteered for the present survey. Results : OW was the most prevalent risk factor (50 %), followed by HT (47%), HCh (33%), SM (13 %) and DM (1.6 %). The proportion of persons without risk factors (RF) was 19.9%, with 1 RF 41.5%, 2 RF 33.8%, 3 RF 4%, and 4 RF 0.9%. OW was more prevalent in men than in women (53% vs. 41%, P=0.02). More men than women aged 41-50 years and 51-60 years had HT (49 % vs. 36%, P=0.01, and 52 % vs. 42%, P=0.02). The prevalence of HCh and DM did not show any sex-related differences. HT, OW and HCh were not only the most common single risk factors, but were also most likely to aggregate with each other. Conclusions : The majority of Swiss people have one or two vascular risk factors. OW and HT are by far most common and are likely to aggregate with each other. A small modification of these two factors would reduce the incidence of stroke and myocardial infarction significantl

    Generalised Hong-Ou-Mandel Experiments with Bosons and Fermions

    Full text link
    The Hong-Ou-Mandel (HOM) dip plays an important role in recent linear optics experiments. It is crucial for quantum computing with photons and can be used to characterise the quality of single photon sources and linear optics setups. In this paper, we consider generalised HOM experiments with NN bosons or fermions passing simultaneously through a symmetric Bell multiport beam splitter. It is shown that for even numbers of bosons, the HOM dip occurs naturally in the coincidence detection in the output ports. In contrast, fermions always leave the setup separately exhibiting perfect coincidence detection. Our results can be used to verify or employ the quantum statistics of particles experimentally.Comment: 11 pages, 2 figures, more references adde

    Observation of correlated-photon statistics using a single detector

    Full text link
    We report experimental observations of correlated-photon statistics in the single-photon detection rate. The usual quantum interference in a two-photon polarization interferometer always accompanies a dip in the single detector counting rate, regardless of whether a dip or peak is seen in the coincidence rate. This effect is explained by taking into account all possible photon number states that reach the detector, rather than considering just the state post-selected by the coincidence measurement. We also report an interferometeric scheme in which the interference peak or dip in coincidence corresponds directly to a peak or dip in the single-photon detection rate.Comment: 4 pages, two-column (minor errors corrected.

    Pulsed energy-time entangled twin-photon source for quantum communication

    Full text link
    A pulsed source of energy-time entangled photon pairs pumped by a standard laser diode is proposed and demonstrated. The basic states can be distinguished by their time of arrival. This greatly simplifies the realization of 2-photon quantum cryptography, Bell state analyzers, quantum teleportation, dense coding, entanglement swapping, GHZ-states sources, etc. Moreover the entanglement is well protected during photon propagation in telecom optical fibers, opening the door to few-photon applications of quantum communication over long distances.Comment: 8 pages, 4 figure
    corecore