718 research outputs found

    Response of the lattice across the filling-controlled Mott metal-insulator transition of a rare earth titanate

    Full text link
    The lattice response of a prototype Mott insulator, SmTiO3, to hole doping is investigated with atomic-scale spatial resolution. SmTiO3 films are doped with Sr on the Sm site with concentrations that span the insulating and metallic sides of the filling-controlled Mott metal-insulator transition (MIT). The GdFeO3-type distortions are investigated using an atomic resolution scanning transmission electron microscopy technique that can resolve small lattice distortions with picometer precision. We show that these distortions are gradually and uniformly reduced as the Sr concentration is increased without any phase separation. Significant distortions persist into the metallic state. The results present a new picture of the physics of this prototype filling-controlled MIT, which is discussed.Comment: Accepted, Phys. Rev. Let

    Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields

    Full text link
    Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs. These designs include a new variety with improved gradiometry that significantly reduces the effective area of both the first and second stage SQUID amplifiers.Comment: 4 pages, 7 figures. Submitted for publication in the IEEE Transactions on Applied Superconductivity, August 201

    Strongly quadrature-dependent noise in superconducting micro-resonators measured at the vacuum-noise limit

    Full text link
    We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement sensitivity. These measurements demonstrate that the excess dissipation-quadrature noise is negligible compared to vacuum fluctuations, at typical readout powers used in micro-resonator applications. Our results have important implications for resonant readout of various devices such as detectors, qubits and nano-mechanical oscillators.Comment: 13 pages, 4 figure

    Advanced code-division multiplexers for superconducting detector arrays

    Full text link
    Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a new in-focal-plane code-division multiplexer that provides multiplexing elements with the required scalability. This code-division multiplexer uses compact lithographic modulation elements that simultaneously multiplex both signal outputs and superconducting transition-edge sensor (TES) detector bias voltages. It eliminates the shunt resistor used to voltage bias TES detectors, greatly reduces power dissipation, allows different dc bias voltages for each TES, and makes all elements sufficiently compact to fit inside the detector pixel area. These in-focal-plane code-division multiplexers can be combined with multi-gigahertz readout based on superconducting microresonators to scale to even larger arrays.Comment: 8 pages, 3 figures, presented at the 14th International Workshop on Low Temperature Detectors, Heidelberg University, August 1-5, 2011, proceedings to be published in the Journal of Low Temperature Physic

    Crosstalk effects in microwave SQUID multiplexed TES bolometer readout

    Full text link
    Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.Comment: Submitted to the Journal of Low Temperature Physic

    Development of Space-Flight Compatible Room-Temperature Electronics for the Lynx X-Ray Microcalorimeter

    Get PDF
    We are studying the development of space-flight compatible room-temperature electronics for the Lynx x-ray microcalorimeter (LXM) of the Lynx mission. The baseline readout technique for the LXM is microwave SQUID multiplexing. The key modules at room temperature are the RF electronics module and the digital electronics and event processor (DEEP). The RF module functions as frequency converters and mainly consists of local oscillators and I/Q mixers. The DEEP performs demultiplexing and event processing, and mainly consists of field-programmable gate arrays, ADCs, and DACs. We designed the RF electronics and DEEP to be flight ready, and estimated the power, size, and mass of those modules. There are two boxes each for the RF electronics and DEEP for segmentation, and the sizes of the boxes are 13 in: 13 in: 9 in: for the RF electronics and 15.5 in: 11.5 in: 9.5 in: for the DEEP. The estimated masses are 25.1 kgbox for the RF electronics box and 24.1 kgbox for the DEEP box. The maximum operating power for the RF electronics is 141 W or 70.5 Wbox, and for the DEEP box is 615 W or 308 Wbox. The overall power for those modules is 756 W. We describe the detail of the designs as well as the approaches to the estimation of resources, sizes, masses, and powers

    ITI-007 demonstrates brain occupancy at serotonin 5-HT2A and dopamine D2 receptors and serotonin transporters using positron emission tomography in healthy volunteers

    No full text
    © 2015 Springer-Verlag Berlin Heidelberg.Rationale: Central modulation of serotonin and dopamine underlies efficacy for a variety of psychiatric therapeutics. ITI-007 is an investigational new drug in development for treatment of schizophrenia, mood disorders, and other neuropsychiatric disorders. Objectives: The purpose of this study was to determine brain occupancy of ITI-007 at serotonin 5-HT2A receptors, dopamine D2 receptors, and serotonin transporters using positron emission tomography (PET) in 16 healthy volunteers. Methods: Carbon-11-MDL100907, carbon-11-raclopride, and carbon-11-3-amino-4-(2-dimethylaminomethyl-phenylsulfanyl)-benzonitrile) (carbon-11-DASB) were used as the radiotracers for imaging 5-HT2A receptors, D2 receptors, and serotonin transporters, respectively. Brain regions of interest were outlined using magnetic resonance tomography (MRT) with cerebellum as the reference region. Binding potentials were estimated by fitting a simplified reference tissue model to the measured tissue-time activity curves. Target occupancy was expressed as percent change in the binding potentials before and after ITI-007 administration. Results: Oral ITI-007 (10-40 mg) was safe and well tolerated. ITI-007 rapidly entered the brain with long-lasting and dose-related occupancy. ITI-007 (10 mg) demonstrated high occupancy (>80 %) of cortical 5-HT2A receptors and low occupancy of striatal D2 receptors (~12 %). D2 receptor occupancy increased with dose and significantly correlated with plasma concentrations (r 2∈=∈0.68, p∈=∈0.002). ITI-007 (40 mg) resulted in peak occupancy up to 39 % of striatal D2 receptors and 33 % of striatal serotonin transporters. Conclusions: The results provide evidence for a central mechanism of action via dopaminergic and serotonergic pathways for ITI-007 in living human brain and valuable information to aid dose selection for future clinical trials

    Targeted next-generation sequencing provides novel clues for associated epilepsy and cardiac conduction disorder/SUDEP

    Get PDF
    Sudden unexpected death in epilepsy is an unpredicted condition in patients with a diagnosis of epilepsy, and autopsy does not conclusively identify cause of death. Although the pathophysiological mechanisms that underlie this entity remain unknown, the fact that epilepsy can affect cardiac function is not surprising. The genetic factors involving ion channels co-expressed in the heart and brain and other candidate genes have been previously described. In the present study, 20 epilepsy patients with personal or family history of heart rhythm disturbance/cardiac arrhythmias/sudden death were sequenced using a custom resequencing panel. Twenty-six relatives were genetically analysed to ascertain the family segregation in ten individuals. Four subjects revealed variants with positive genotype-phenotype segregation: four missense variants in the CDKL5, CNTNAP2, GRIN2A and ADGRV1 genes and one copy number variant in KCNQ1. The potential pathogenic role of variants in new candidate genes will need further studies in larger cohorts, and the evaluation of the potential pathogenic role in the cardio-cerebral mechanisms requires in vivo/in vitro studies. In addition to family segregation, evaluation of the potential pathogenic roles of these variants in cardio-cerebral mechanisms by in vivo/in vitro studies should also be performed. The potential pathogenic role of variants in new candidate genes will need further studies in larger cohorts
    • …
    corecore