3 research outputs found
Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.Peer reviewe
Initial multicenter experience with a new high-density coloring module: impact for complex atrial arrhythmias interpretation
International audienc
High Risk of Sustained Ventricular Arrhythmia Recurrence After Acute Myocarditis
International audienceAcute myocarditis is associated with cardiac arrhythmia in 25% of cases; a third of these arrhythmias are ventricular tachycardia (VT) or ventricular fibrillation (VF). The implantation of a cardiac defibrillator (ICD) following sustained ventricular arrhythmia remains controversial in these patients. We sought to assess the risk of major arrhythmic ventricular events (MAEs) over time in patients implanted with an ICD following sustained VT/VF in the acute phase of myocarditis compared to those implanted for VT/VF occurring on myocarditis sequelae. Our retrospective observational study included patients implanted with an ICD following VT/VF during acute myocarditis or VT/VF on myocarditis sequelae, from 2007 to 2017, in 15 French university hospitals. Over a median follow-up period of 3 years, MAE occurred in 11 (39%) patients of the acute myocarditis group and 24 (60%) patients of the myocarditis sequelae group. Kaplan-Meier MAE rate estimates at one and three years of follow-up were 19% and 45% in the acute group, and 43% and 64% in the sequelae group. Patients who experienced sustained ventricular arrhythmias during acute myocarditis had a very high risk of VT/VF recurrence during follow-up. These results show that the risk of MAE recurrence remains high after resolution of the acute episode