19,707 research outputs found

    Light-related variation in sapling architecture of three shade-tolerant tree species of the Mexican rain forest

    Get PDF
    The crown architecture of three shade-tolerant tree species (two subcanopy and one mid-canopy) was analyzed in relation to the light regime of the forest understorey. The aim was to examine to which extent shade-tolerant species variate in their crown architecture. Tree saplings (265) between 50 and 300 cm height, and distributed from understorey to variously-sized canopy gaps, were measured for 13 architectural traits in the lowland rain forest of Los Tuxtlas, Mexico. The analysis showed that the three species changed their architecture as light increased but in a different way. No species conformed to the typical wide-crown type expected for shade-tolerant species, and in contrast they presented some traits of light demanding species. The two sub-canopy species tended to adopt a crown form between a narrow- and wide-crown type, and the mid-canopy species showed more traits of a narrow-crown type. The horizontal crown area appeared as the more related trait to the light and sapling height. It is concluded that despite being shade-tolerant, the Studied species make use of better-lit environments in the forest understorey. The crown architecture of shade-tolerant species is not Lis rigid Lis originally conceived

    A method for determining the radius of an open cluster from stellar proper motions

    Full text link
    We propose a method for calculating the radius of an open cluster in an objective way from an astrometric catalogue containing, at least, positions and proper motions. It uses the minimum spanning tree (hereinafter MST) in the proper motion space to discriminate cluster stars from field stars and it quantifies the strength of the cluster-field separation by means of a statistical parameter defined for the first time in this paper. This is done for a range of different sampling radii from where the cluster radius is obtained as the size at which the best cluster-field separation is achieved. The novelty of this strategy is that the cluster radius is obtained independently of how its stars are spatially distributed. We test the reliability and robustness of the method with both simulated and real data from a well-studied open cluster (NGC 188), and apply it to UCAC4 data for five other open clusters with different catalogued radius values. NGC 188, NGC 1647, NGC 6603 and Ruprecht 155 yielded unambiguous radius values of 15.2+/-1.8, 29.4+/-3.4, 4.2+/-1.7 and 7.0+/-0.3 arcmin, respectively. ASCC 19 and Collinder 471 showed more than one possible solution but it is not possible to know whether this is due to the involved uncertainties or to the presence of complex patterns in their proper motion distributions, something that could be inherent to the physical object or due to the way in which the catalogue was sampled.Comment: 12 pages including 14 figures and 1 table. Accepted for publication in MNRA

    Coulomb displacement energies, energy differenced and neutron skins

    Get PDF
    A Fock space representation of the monopole part of the Coulomb potential is presented. Quantum effects show through a small orbital term in l(l+1)l(l+1). Once it is averaged out, the classical electrostatic energy emerges as an essentially exact expression, which makes it possible to eliminate the Nolen-Schiffer anomaly, and to estimate neutron skins and the evolution of radii along yrast states of mirror nuclei. The energy differences of the latter are quantitatively reproduced by the monopole term and a schematic multipole one.Comment: 4 pages, 3 figures, Revte

    Fuzzy Inference System for VOLT/VAR control in distribution substations in isolated power systems

    Full text link
    This paper presents a fuzzy inference system for voltage/reactive power control in distribution substations. The purpose is go forward to automation distribution and its implementation in isolated power systems where control capabilities are limited and it is common using the same applications as in continental power systems. This means that lot of functionalities do not apply and computational burden generates high response times. A fuzzy controller, with logic guidelines embedded based upon heuristic rules resulting from operators at dispatch control center past experience, has been designed. Working as an on-line tool, it has been tested under real conditions and it has managed the operation during a whole day in a distribution substation. Within the limits of control capabilities of the system, the controller maintained successfully an acceptable voltage profile, power factor values over 0,98 and it has ostensibly improved the performance given by an optimal power flow based automation system
    • 