105 research outputs found

    Tissue Distribution and Elimination of Isavuconazole following Single and Repeat Oral-Dose Administration of Isavuconazonium Sulfate to Rats

    Get PDF
    ABSTRACT Quantitative whole-body autoradiography was used to assess the distribution and tissue penetration of isavuconazole in rats following single and repeated oral-dose administration of radiolabeled isavuconazonium sulfate, the prodrug of isavuconazole. Following a single-dose administration of radiolabeled isavuconazonium sulfate (labeled on the active moiety), radioactivity was detectable within 1 h postdose in 56 of 65 tissue/fluid specimens. The highest maximum concentrations ( C max ) were observed in bile and liver (66.6 and 24.7 ÎŒg eq/g, respectively). The lowest C max values were in bone and eye lens (0.070 and 0.077 ÎŒg eq/g, respectively). By 144 h postdose, radioactivity was undetectable in all tissues/fluids except liver (undetectable at 336 h) and adrenal gland tissues (undetectable at 672 h). Following daily administration for up to 21 days, 1-h-postdose C max values were the highest on or before day 14 in all except seven tissues/fluids, of which only rectum mucosa and small intestine mucosa had C max values &gt;25% higher than all other 1-h-postdose values. For 24-h-postdose C max values, only large intestine, large intestine mucosa, and urine had the highest C max values at day 21. The penetration of single oral doses of unlabeled isavuconazole (25 mg/kg of body weight isavuconazonium sulfate) and voriconazole (50 mg/kg) into rat brain (assessed using liquid chromatography-tandem mass spectrometry) was also compared. Brain concentration/plasma concentration ratios reached approximately 1.8:1 and 2:1, respectively. These data suggest that isavuconazole penetrates most tissues rapidly, reaches a steady state in most or all tissues/fluids within 14 days, does not accumulate in tissues/fluids over time, and achieves potentially efficacious concentrations in the brain. </jats:p

    177 Lu-PSMA-617 radioligand therapy of metastatic castration-resistant prostate cancer: Initial 254-patient results from a prospective registry (REALITY Study)

    Get PDF
    Purpose Preliminary data from retrospective analyses and recent data from large randomized controlled trials suggest safety and efcacy of radioligand therapy (RLT) targeting prostate-specifc membrane antigen (PSMA) in men with metastatic castration-resistant prostate cancer (mCRPC). Limited data on this modality have been published regarding large samples treated in everyday practice. Methods We analyzed prospectively collected registry data regarding lutetium-177 (177Lu)-PSMA-617 RLT of 254 consecu tive men with mCRPC seen in everyday academic practice. Since 177Lu-PSMA-617 was experimental salvage treatment following failure of individually appropriate conventional therapies, patients were generally elderly and heavily pretreated (median age 70 years; prior taxanes 74.0%, 188/254), with late–end-stage disease (visceral metastasis in 32.7%, 83/254). Primary endpoints were response to RLT, defned by changes from baseline serum prostate-specifc antigen (PSA) concen tration, PSA progression-free survival (PSA-PFS), and overall survival (OS), estimated with Kaplan–Meier statistics, and caregiver-reported and patient-reported safety. Unless noted, median (minimum–maximum) values are given. Results Patients received 3 (1–13) 177Lu-PSMA-617 activities (6.5 [2.5–11.6] GBq/cycle) every 5.7 (3.0–11.0) weeks. Best response was≄50% PSA reduction in 52.0% of patients (132/254). PSA-PFS was 5.5 (95% confdence interval [95%CI] 4.4–6.6) months and OS, 14.5 (95%CI 11.5–17.5) months. In multivariable Cox proportional-hazards modeling, response to the initial≀2 RLT administrations was the strongest signifcant prognosticator related to OS (hazard ratio 3.7 [95%CI 2.5–5.5], p<0.001). No RLT-related deaths or treatment discontinuations occurred; the most frequent RLT-related Grade 3/4 adverse events were anemia (18/254 patients, 7.1%), thrombocytopenia (11/254, 4.3%), and lymphopenia (7/254, 2.8%). RLT-related xerostomia, all grade 1/2, was noted in 53/254 (20.9%). Conclusions In a large, prospectively observed “real-world” cohort with late-stage/end-stage mCRPC and conventional treatment failure, 177Lu-PSMA-617 RLT was efective, safe, and well-tolerated. Early biochemical disease control by such therapy was associated with better OS. Prospective study earlier in the disease course may be warranted

    Detection efficacy of [89Zr]Zr-PSMA-617 PET/CT in [68Ga]Ga-PSMA-11 PET/CT-negative biochemical recurrence of prostate cancer

    Get PDF
    Rationale In patients with biochemical recurrence of prostate cancer (BCR), preliminary data suggest that prostate-specifc membrane antigen (PSMA) ligand radiotracers labeled with zirconium-89 (89Zr; half-life ~ 78.41 h), which allow imaging≄24 h post-injection, detect suspicious lesions that are missed when using tracers incorporating short-lived radionuclides. Materials and methods To confrm [ 89Zr]Zr-PSMA-617 positron emission tomography/computed tomography (PET/CT) detection efcacy regarding such lesions, and compare quality of 1-h, 24-h, and 48-h [ 89Zr]Zr-PSMA-617 scans, we retrospectively analyzed visual fndings and PET variables refecting lesional [ 89Zr]Zr-PSMA-617 uptake and lesion-to-background ratio. The cohort comprised 23 men with BCR post-prostatectomy, median (minimum–maximum) prostate-specifc antigen (PSA) 0.54 (0.11–2.50) ng/mL, and negative [ 68Ga]Ga-PSMA-11 scans 40±28 d earlier. Primary endpoints were percentages of patients with, and classifcations of, suspicious lesions. Results Altogether, 18/23 patients (78%) had 36 suspicious lesions (minimum–maximum per patient: 1–4) on both 24-h and 48-h scans (n=33 lesions) or only 48-h scans (n=3 lesions). Only one lesion appeared on a 1-h scan. Lesions putatively represented local recurrence in 11 cases, and nodal or bone metastasis in 21 or 4 cases, respectively; 1/1 lesion was histologically confrmed as a nodal metastasis. In all 15 patients given radiotherapy based on [ 89Zr]Zr-PSMA-617 PET/CT, PSA values decreased after this treatment. Comparison of PET variables in 24-h vs 48-h scans suggested no clear superiority of either regarding radiotracer uptake, but improved lesion-to-background ratio at 48 h. Conclusions In men with BCR and low PSA, [ 89Zr]Zr-PSMA-617 PET/CT seems efective in fnding prostate malignancy not seen on [ 68Ga]Ga-PSMA-11 PET/CT. The higher detection rates and lesion-to-background ratios of 48-h scans versus 24-h scans suggest that imaging at the later time may be preferable. Prospective study of [ 89Zr]Zr-PSMA-617 PET/CT is warranted

    Tumor Sink Effect with Prostate-Specific Membrane Antigen-Targeted Theranostics in Patients with Metastatic Castration-Resistant Prostate Cancer: Intra-Individual Evaluations

    Get PDF
    “Tumor sink effects”, decreased physiological uptake of radiopharmaceuticals due to sequestration by a tumor, may impact radioligand therapy (RLT) toxicity and dosing. We investigated these effects with prostate-specific membrane antigen (PSMA)-targeted radiopharmaceuticals in the healthy organs-at-risk (the parotid glands, kidneys, liver, and spleen) of 33 patients with metastatic castration-resistant prostate cancer (mCRPC). We retrospectively performed three intra-individual comparisons. First, we correlated changes from baseline to post-RLT (after two 177-lutetium (177Lu)-PSMA-617 cycles) in total lesional PSMA (∆TLP) and organ mean standardized uptake values (∆SUVmean). Second, in 25 RLT responders, we compared the organ SUVmean post-RLT versus that at baseline. Lastly, we correlated the baseline TLP and organ SUVmean. Data were acquired via 68-gallium-PSMA-11 positron emission tomography before the first and after the second 177Lu-PSMA-617 cycle. In the parotid glands and spleen, ∆TLP and ∆SUVmean showed a significant inverse correlation (r = −0.40, p = 0.023 and r = −0.36, p = 0.042, respectively). Additionally, in those tissues, the median organ SUVmean rose significantly from baseline after the response to RLT (p ≀ 0.022), and the baseline TLP and SUVmean were significantly negatively correlated (r = −0.44, p = 0.01 and r = −0.42, p = 0.016, respectively). These observations suggest tumor sink effects with PSMA-targeted radiopharmaceuticals in the salivary glands and spleen of patients with mCRPC

    Detection Efficacy of 68Ga-PSMA-11 PET/CT in Biochemical Recurrence of Prostate Cancer with Very Low PSA Levels : A 7-Year, Two-Center “Real-World” Experience

    Get PDF
    In biochemical recurrence of prostate cancer (BCR), prompt tumor localization guides early treatment, potentially improving patient outcomes. Gallium-68 prostate-specific membrane antigen11 positron emission tomography/computed tomography (68Ga-PSMA-11 PET/CT) detection rates of lesions suspicious for prostate cancer are well known to rise along with prostate-specific antigen (PSA) concentration. However, published data are limited regarding very low values (≀0.2 ng/mL). We retrospectively analyzed ~7-year “real-world” experience in this setting in a large post-prostatectomy cohort (N = 115) from two academic clinics. Altogether 44 lesions were detected in 29/115 men (25.2%) (median [minimum–maximum] 1 [1–4]/positive scan). The apparent oligometastatic disease was found in nine patients (7.8%) at PSA as low as 0.03 ng/mL. Scan positivity rates were highest when PSA was >0.15 ng/mL, PSA doubling time was ≀12 months, or the Gleason score was ≄7b (in 83 and 107 patients, respectively, with available data); these findings were statistically significant (p ≀ 0.04), except regarding PSA level (p = 0.07). Given the benefits of promptly localizing recurrence, our observations suggest the potential value of 68Ga-PSMA-11 PET/CT in the very low PSA BCR setting, especially in cases with more rapid PSA doubling time or with high-risk histology

    Research Progress Reports, 1962. Fruit and Vegetable Processing and Technology Division, Department of Horticulture.

    Get PDF
    Tomato variety evaluation for processing, 1962 / W. A. Gould, J. R. Geisman and Wade Schulte -- Evaluation of snap bean varieties for processing, 1962 / Wilbur A. Gould -- Handling and holding studies of mechanically harvested tomatoes. 1. Processed product quality / W. A. Gould, W. D. Bash, J. R. Geisman, D. E. Yingst, G. A. Marlowe and W. N. Brown -- Handling and holding studies of mechanically harvested tomatoes. 2. Spore counts / Winston D. Bash and W. A. Gould -- Handling and holding studies of mechanically harvested tomatoes. 3. pH / Winston D. Bash and W. A. Gould -- Handling and holding studies of mechanically harvested tomatoes. 4. Chlorine residuals / Donald E. Yingst and W. A. Gould -- Removal of insects and residues from sweet corn by washing techniques / J. R. Geisman and W. A. Gould -- Removal of pesticides and radioactive fallout from fruits and vegetables / J. R. Geisman, R. P. Blackmore, R. W. Hirzel and W. S. Stinson -- The effect of apple variety and browning prevention treatments during preparation on the quality of frozen apple pies / D. Robert Davis and James F. Gallander -- Effect of three tomato peeling methods on efficiency and product quality / Wade A. Schulte and W. A. Gould -- Effects of cooling rates on vacuum of canned pumpkin / Winston D. Bash -- New flavors for sauerkraut / J. R. Geisman and Robert Reyda -- Flavor of tomato juice / Wilbur A. Gould, Natholyn Dalton and John Hal Johnson -- Fruit juice blends offer a promising new field for apple cider / D. Robert Davi

    Improved molecular laboratory productivity by consolidation of testing on the new random-access analyzer Alinity m

    Get PDF
    Abstract Objectives Automated molecular analyzers have accelerated diagnosis, allowing earlier intervention and better patient follow-up. A recently developed completely automated molecular analyzer, Alinityℱ m (Abbott), offers consolidated, continuous, and random-access testing that may improve molecular laboratory workflow. Methods An international, multicenter study compared laboratory workflow metrics across various routine analyzers and Alinity m utilizing assays for human immunodeficiency virus type 1 (HIV-1), hepatitis C virus (HCV), hepatitis B virus (HBV), high-risk human papillomavirus (HR HPV), and sexually transmitted infection (STI) (Chlamydia trachomatis [CT]/Neisseria gonorrhoeae [NG]/Trichomonas vaginalis [TV]/Mycoplasma genitalium [MG]). Three turnaround times (TATs) were assessed: total TAT (sample arrival to result), sample onboard TAT (sample loading and test starting to result), and processing TAT (sample aspiration to result). Results Total TAT was reduced from days with routine analyzers to hours with Alinity m, independent of requested assays. Sample onboard TATs for standard workflow using routine analyzers ranged from 7 to 32.5 h compared to 2.75–6 h for Alinity m. The mean sample onboard TAT for STAT samples on Alinity m was 2.36 h (±0.19 h). Processing TATs for Alinity m were independent of the combination of assays, with 100% of results reported within 117 min. Conclusions The consolidated, continuous, random-access workflow of Alinity m reduces TATs across various assays and is expected to improve both laboratory operational efficiency and patient care

    Reply to van Hoorn: Converging lines of evidence

    Get PDF
    We agree with the comments by van Hoorn (1) on our critique (2): testing causal hypotheses about human behavior is a challenge (1, 3). Making progress requires specifying alternative hypotheses and then testing these hypotheses using diverse and converging lines of evidence. We have defended the hypothesis that social norms, which culturally coevolved with the institutions of large-scale societies including markets, influence economic decision-making. This hypothesis emerged from a larger set that we developed both at the outset of our project and as we went along. Our interdisciplinary team’s initial list of hypotheses included the idea that experimental games might spark an innate reciprocity module that would yield little variation across populations

    Multicenter clinical comparative evaluation of Alinity m HIV-1 assay performance.

    Get PDF
    Abstract Background Accurate, rapid detection of HIV-1 RNA is critical for early diagnosis, treatment decision making, and long-term management of HIV-1 infection. Objective We evaluated the diagnostic performance of the Alinity m HIV-1 assay, which uses a dual target/dual probe design against highly conserved target regions of the HIV-1 genome and is run on the fully automated Alinity m platform. Study design This was an international, multisite study that compared the diagnostic performance of the Alinity m HIV-1 assay to four commercially available HIV-1 assays routinely used in nine independent clinical laboratories. Alinity m HIV-1 assay precision, detectability, and reproducibility was compared across four study sites. Results The Alinity m HIV-1 assay produced comparable results to currently available HIV-1 assays (correlation coefficient >0.995), with an overall bias of -0.1 to 0.10 Log10 copies/mL. The Alinity m HIV-1 assay and its predecessor m2000 HIV-1 assay demonstrated comparable detection of 16 different HIV-1 subtypes (R2 = 0.956). A high level of agreement (>88 %) between all HIV-1 assays was seen near clinical decision points of 1.7 Log10 copies/mL (50 copies/mL) and 2.0 Log10 copies/mL (200 copies/mL). Alinity m HIV-1 assay precision was 0.08 and 0.21 Log10 copies/mL at VLs of 1000 and 50 copies/mL, respectively, with a high level of detectability (≄97 % hit rate) and reproducibility across sites. Conclusions The Alinity m HIV-1 assay provides comparable diagnostic accuracy to current HIV-1 assays, and when run on the Alinity m system, has the capacity to shorten the time between diagnosis and treatment
    • 

    corecore