3,679 research outputs found

    Identification of Hemodynamically Optimal Coronary Stent Designs Based on Vessel Caliber

    Get PDF
    Coronary stent design influences local patterns of wall shear stress (WSS) that are associated with neointimal growth, restenosis, and the endothelialization of stent struts. The number of circumferentially repeating crowns NC for a given stent de- sign is often modified depending on the target vessel caliber, but the hemodynamic implications of altering NC have not previously been studied. In this investigation, we analyzed the relationship between vessel diameter and the hemodynamically optimal NC using a derivative-free optimization algorithm coupled with computational fluid dynamics. The algorithm computed the optimal vessel diameter, defined as minimizing the area of stent-induced low WSS, for various configurations (i.e., NC) of a generic slotted-tube design and designs that resemble commercially available stents. Stents were modeled in idealized coronary arteries with a vessel diameter that was allowed to vary between 2 and 5 mm. The results indicate that the optimal vessel diameter increases for stent configurations with greater NC, and the designs of current commercial stents incorporate a greater NC than hemodynamically optimal stent designs. This finding suggests that reducing the NC of current stents may improve the hemodynamic environment within stented arteries and reduce the likelihood of excessive neointimal growth and thrombus formation

    Image-based Quantification of 3D Morphology for Bifurcations in the Left Coronary Artery: Application to Stent Design

    Get PDF
    Background Improved strategies for stent‐based treatment of coronary artery disease at bifurcations require a greater understanding of artery morphology. Objective We developed a workflow to quantify morphology in the left main coronary (LMCA), left anterior descending (LAD), and left circumflex (LCX) artery bifurcations. Methods Computational models of each bifurcation were created for 55 patients using computed tomography images in 3D segmentation software. Metrics including cross‐sectional area, length, eccentricity, taper, curvature, planarity, branching law parameters, and bifurcation angles were assessed using open‐sources software and custom applications. Geometric characterization was performed by comparison of means, correlation, and linear discriminant analysis (LDA). Results Differences between metrics suggest dedicated or multistent approaches should be tailored for each bifurcation. For example, the side branch of the LCX (i.e., obtuse marginal; OM) was longer than that of the LMCA (i.e., LCXprox) and LAD (i.e., first diagonal; D1). Bifurcation metrics for some locations (e.g., LMCA Finet ratio) provide results and confidence intervals agreeing with prior findings, while revised metric values are presented for others (e.g., LAD and LCX). LDA revealed several metrics that differentiate between artery locations (e.g., LMCA vs. D1, LMCA vs. OM, LADprox vs. D1, and LCXprox vs. D1). Conclusions These results provide a foundation for elucidating common parameters from healthy coronary arteries and could be leveraged in the future for treating diseased arteries. Collectively the current results may ultimately be used for design iterations that improve outcomes following implantation of future dedicated bifurcation stents

    Seeing with sound? Exploring different characteristics of a visual-to-auditory sensory substitution device

    Get PDF
    Sensory substitution devices convert live visual images into auditory signals, for example with a web camera (to record the images), a computer (to perform the conversion) and headphones (to listen to the sounds). In a series of three experiments, the performance of one such device (‘The vOICe’) was assessed under various conditions on blindfolded sighted participants. The main task that we used involved identifying and locating objects placed on a table by holding a webcam (like a flashlight) or wearing it on the head (like a miner’s light). Identifying objects on a table was easier with a hand-held device, but locating the objects was easier with a head-mounted device. Brightness converted into loudness was less effective than the reverse contrast (dark being loud), suggesting that performance under these conditions (natural indoor lighting, novice users) is related more to the properties of the auditory signal (ie the amount of noise in it) than the cross-modal association between loudness and brightness. Individual differences in musical memory (detecting pitch changes in two sequences of notes) was related to the time taken to identify or recognise objects, but individual differences in self-reported vividness of visual imagery did not reliably predict performance across the experiments. In general, the results suggest that the auditory characteristics of the device may be more important for initial learning than visual associations

    Availability of High Quality TRMM Ground Validation Data from Kwajalein, RMI: A Practical Application of the Relative Calibration Adjustment Technique

    Get PDF
    Since the Tropical Rainfall Measuring Mission (TRMM) satellite launch in November 1997, the TRMM Satellite Validation Office (TSVO) at NASA Goddard Space Flight Center (GSFC) has been performing quality control and estimating rainfall from the KPOL S-band radar at Kwajalein, Republic of the Marshall Islands. Over this period, KPOL has incurred many episodes of calibration and antenna pointing angle uncertainty. To address these issues, the TSVO has applied the Relative Calibration Adjustment (RCA) technique to eight years of KPOL radar data to produce Ground Validation (GV) Version 7 products. This application has significantly improved stability in KPOL reflectivity distributions needed for Probability Matching Method (PMM) rain rate estimation and for comparisons to the TRMM Precipitation Radar (PR). In years with significant calibration and angle corrections, the statistical improvement in PMM distributions is dramatic. The intent of this paper is to show improved stability in corrected KPOL reflectivity distributions by using the PR as a stable reference. Inter-month fluctuations in mean reflectivity differences between the PR and corrected KPOL are on the order of 1-2 dB, and inter-year mean reflectivity differences fluctuate by approximately 1 dB. This represents a marked improvement in stability with confidence comparable to the established calibration and uncertainty boundaries of the PR. The practical application of the RCA method has salvaged eight years of radar data that would have otherwise been unusable, and has made possible a high-quality database of tropical ocean-based reflectivity measurements and precipitation estimates for the research community

    Multiple metrics for quantifying the intensity of water consumption of energy production

    Get PDF
    Discussion of the environmental implications of worldwide energy demand is currently dominated by the effects of carbon dioxide (CO[subscript 2]) emissions on global climate. At the regional scale, however, water resource challenges associated with energy systems are a growing concern. This paper, based on an inventory of national energy portfolios, posits an indicator-based framework for characterizing regional energy portfolios' relative water intensity. These calculations extend upon a previous paper that established a method for calculating the national water consumption of energy production (WCEP) at the global level. Intensity indicators are based on normalizing the WCEP results with a set of additional indicators (including population, gross domestic product, total energy production, and regional water availability). The results show great variability in water consumption across nations, as well as across the various water intensity measures that were applied. Therefore, it is best to apply this full suite of indicators to each country to develop an integrated understanding of the intensity of water use for energy across countries

    The water consumption of energy production: an international comparison

    Get PDF
    Producing energy resources requires significant quantities of fresh water. As an energy sector changes or expands, the mix of technologies deployed to produce fuels and electricity determines the associated burden on regional water resources. Many reports have identified the water consumption of various energy production technologies. This paper synthesizes and expands upon this previous work by exploring the geographic distribution of water use by national energy portfolios. By defining and calculating an indicator to compare the water consumption of energy production for over 150 countries, we estimate that approximately 52 billion cubic meters of fresh water is consumed annually for global energy production. Further, in consolidating the data, it became clear that both the quality of the data and global reporting standards should be improved to track this important variable at the global scale. By introducing a consistent indicator to empirically assess coupled water–energy systems, it is hoped that this research will provide greater visibility into the magnitude of water use for energy production at the national and global scales

    Incentivizing preventive services in primary care: perspectives on Local Enhanced Services

    Get PDF
    Background: General practitioners in the UK play a key role in prevention but provision of preventive services is variable. The 2004 General Medical Services contract allows Primary Care Trusts (PCTs) to address health needs through providing locally agreed payments for Local Enhanced Services (LESs). This study identifies how this contractual flexibility is used for preventive services and explores its perceived effectiveness. Methods: Semi-structured interviews were carried out (2008–09) in 10 purposively selected case study sites in England. Details of LESs for these sites were collected (2009) through Freedom of Information requests or local contacts. A national on-line survey of PCTs (2009) provided a national context for case study findings. Results: LESs were considered to be effective in incentivizing preventive activity. However, specifications and performance management were often weak, awareness of how to optimize incentives was low and, as optional services, LESs were perceived to be at risk in a financial downturn. Conclusions: Using LESs for preventive services highlights gaps in ‘core’ primary care responsibilities and in the national pay-for-performance framework. Current incentive arrangements are complex, could increase inequalities and provide only a partial, short-term solution to developing a proactive approach to prevention in primary care
    • 