108 research outputs found

    Left ventricular dysfunction with reduced functional cardiac reserve in diabetic and non-diabetic LDL-receptor deficient apolipoprotein B100-only mice

    Get PDF
    BACKGROUND: Lack of suitable mouse models has hindered the studying of diabetic macrovascular complications. We examined the effects of type 2 diabetes on coronary artery disease and cardiac function in hypercholesterolemic low-density lipoprotein receptor-deficient apolipoprotein B100-only mice (LDLR(-/-)ApoB(100/100)). METHODS AND RESULTS: 18-month-old LDLR(-/-)ApoB(100/100 )(n = 12), diabetic LDLR(-/-)ApoB(100/100 )mice overexpressing insulin-like growth factor-II (IGF-II) in pancreatic beta cells (IGF-II/LDLR(-/-)ApoB(100/100), n = 14) and age-matched C57Bl/6 mice (n = 15) were studied after three months of high-fat Western diet. Compared to LDLR(-/-)ApoB(100/100 )mice, diabetic IGF-II/LDLR(-/-)ApoB(100/100 )mice demonstrated more calcified atherosclerotic lesions in aorta. However, compensatory vascular enlargement was similar in both diabetic and non-diabetic mice with equal atherosclerosis (cross-sectional lesion area ~60%) and consequently the lumen area was preserved. In coronary arteries, both hypercholesterolemic models showed significant stenosis (~80%) despite positive remodeling. Echocardiography revealed severe left ventricular systolic dysfunction and anteroapical akinesia in both LDLR(-/-)ApoB(100/100 )and IGF-II/LDLR(-/-)ApoB(100/100 )mice. Myocardial scarring was not detected, cardiac reserve after dobutamine challenge was preserved and ultrasructural changes revealed ischemic yet viable myocardium, which together with coronary artery stenosis and slightly impaired myocardial perfusion suggest myocardial hibernation resulting from chronic hypoperfusion. CONCLUSIONS: LDLR(-/-)ApoB(100/100 )mice develop significant coronary atherosclerosis, severe left ventricular dysfunction with preserved but diminished cardiac reserve and signs of chronic myocardial hibernation. However, the cardiac outcome is not worsened by type 2 diabetes, despite more advanced aortic atherosclerosis in diabetic animals

    Cardiomyopathy associated with the Ala143Thr variant of the α-galactosidase A gene

    Get PDF
    Objective To investigate whether the Ala143Thr variant of the α-galactosidase A gene (A143T/GLA), with conflicting interpretations of pathogenicity, is associated with Fabry cardiomyopathy.Methods The index patient, a woman in her 60s with cardiomyopathy, was screened for variants in 59 cardiomyopathy-related genes. A143T/GLA, the only rare variant found, was screened in 10 relatives. GLA activity and lyso-Gb3 levels were measured and echocardiography was performed in 8 of 9 subjects carrying A143T/GLA. Cardiac magnetic resonance (CMR) imaging and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) were performed in four adult A143T/GLA carriers. Endomyocardial biopsy was obtained from two adult A143T/GLA carrying sons of the index patient.Results The index patient and her elder son had a pacemaker implantation because of sick sinus syndrome and atrioventricular block. GLA activities were decreased to 25%–40% of normal in both sons and one granddaughter. Lyso-Gb3 levels were elevated in both sons. In CMR, the index patient and her two sons had left ventricular (LV) hypertrophy and/or dilatation. The elder son had late gadolinium enhancement, high CMR-derived T1 time and positive FDG signal in PET/CT in the basal inferolateral LV wall. The younger son had low T1 time and the mother had positive FDG signal in PET/CT in the basal inferolateral LV wall. Endomyocardial biopsy of both sons showed myocardial accumulation compatible with glycolipids in light and electron microscopy, staining with anti-Gb3 antibody available for the younger son. Five female relatives with A143T/GLA had no cardiomyopathy in cardiac imaging.Conclusions A143T/GLA is likely a late-onset Fabry cardiomyopathy causing variant with incomplete penetrance.</p

    Synthetic mRNA Encoding VEGF-A in Patients Undergoing Coronary Artery Bypass Grafting: Design of a Phase 2a Clinical Trial

    Get PDF
    Therapeutic angiogenesis may improve outcomes in patients with coronary artery disease undergoing surgical revascularization. Angiogenic factors may promote blood vessel growth and regenerate regions of ischemic but viable myocardium. Previous clinical trials of vascular endothelial growth factor A (VEGF-A) gene therapy with DNA or viral vectors demonstrated safety but not efficacy. AZD8601 is VEGF-A165 mRNA formulated in biocompatible citrate-buffered saline and optimized for high-efficiency VEGF-A expression with minimal innate immune response. EPICCURE is an ongoing randomized, double-blind, placebo-controlled study of the safety of AZD8601 in patients with moderately decreased left ventricular function (ejection fraction 30%–50%) undergoing elective coronary artery bypass surgery. AZD8601 3 mg, 30 mg, or placebo is administered as 30 epicardial injections in a 10-min extension of cardioplegia. Injections are targeted to ischemic but viable myocardial regions in each patient using quantitative 15O-water positron emission tomography (PET) imaging (stress myocardial blood flow 0.6 mL/g/min). Improvement in regional and global myocardial blood flow quantified with 15O-water PET is an exploratory efficacy outcome, together with echocardiographic, clinical, functional, and biomarker measures. EPICCURE combines high-efficiency delivery with quantitative targeting and follow-up for robust assessment of the safety and exploratory efficacy of VEGF-A mRNA angiogenesis (ClinicalTrials.gov: NCT03370887).</p

    Artificial Intelligence for Hospital Health Care:Application Cases and Answers to Challenges in European Hospitals

    Get PDF
    The development and implementation of artificial intelligence (AI) applications in health care contexts is a concurrent research and management question. Especially for hospitals, the expectations regarding improved efficiency and effectiveness by the introduction of novel AI applications are huge. However, experiences with real-life AI use cases are still scarce. As a first step towards structuring and comparing such experiences, this paper is presenting a comparative approach from nine European hospitals and eleven different use cases with possible application areas and benefits of hospital AI technologies. This is structured as a current review and opinion article from a diverse range of researchers and health care professionals. This contributes to important improvement options also for pandemic crises challenges, e.g., the current COVID-19 situation. The expected advantages as well as challenges regarding data protection, privacy, or human acceptance are reported. Altogether, the diversity of application cases is a core characteristic of AI applications in hospitals, and this requires a specific approach for successful implementation in the health care sector. This can include specialized solutions for hospitals regarding human-computer interaction, data management, and communication in AI implementation projects

    4D Flow Versus 2D Phase Contrast MRI in Populations With Bi- and Tricuspid Aortic Valves

    Get PDF
    Aim: To compare 4D flow magnetic resonance imaging (MRI) and 2D phase contrast (PC) MRI when evaluating bicuspid (BAV) and tricuspid (TAV) aortic valves. Materials and Methods: A total of 83 subjects (35 BAV, 48 TAV) were explored with 4D flow and 2D PC MRI. Systolic peak velocity, peak flow and regurgitation fraction were analysed at two pre-defined aortic levels (aortic root, mid-tubular). Furthermore, the two methods of 4D flow analysis (Heart and Artery) were compared. Results: Correlation between the 2D PC MRI and 4D flow MRI derived parameters ranged from moderate (R=0.58) to high (R=0.90). 4D flow MRI yielded significantly higher peak velocities in the tubular aorta in both groups. Regarding the aortic root, peak velocities were significantly higher in the TAV group with 4D flow MRI, but in the BAV group 4D flow MRI yielded non-significantly lower values. Findings on peak flow differences between the two modalities followed the same pattern as the differences in peak velocities. 4D flow MRI derived regurgitation fraction values were lower in both locations in both groups. Interobserver agreement for different 4D flow MRI acquired parameters varied from poor (ICC=0.07) to excellent (ICC=1.0) in the aortic root, and it was excellent in the tubular aorta (ICC=0.8-1.0). Conclusion: 4D flow MRI seems to be accurate in comparison to 2D PC MRI in normal aortic valves and in BAV with mild to moderate stenosis. However, the varying interobserver reproducibility and impaired accuracy at higher flow velocities should be taken into account in clinical practice when using the 4D flow method.publishedVersionPeer reviewe

    Design and rationale of FLAVOUR: A phase IIa efficacy study of the 5-lipoxygenase activating protein antagonist AZD5718 in patients with recent myocardial infarction

    Get PDF
    levels is the primary efficacy outcome. FLAVOUR also aims to evaluate whether AZD5718 can improve coronary microvascular function, as measured by transthoracic colour Doppler-assisted coronary flow velocity reserve. Centrally pretrained study sonographers use standardized protocols and equipment. Additional outcomes include assessment of comprehensive echocardiographic parameters (including coronary flow, global strain, early diastolic strain rate and left ventricular ejection fraction), arterial stiffness, biomarkers, health-related quality of life, and safety. Specific anti-inflammatory therapies may represent novel promising treatments to reduce residual risk in patients with coronary artery disease. By combining primary pharmacodynamic and secondary cardiovascular surrogate efficacy outcomes, FLAVOUR aims to investigate the mechanistic basis and potential benefits of AZD5718 treatment in patients with coronary artery disease
    • 

    corecore