15 research outputs found

    Application and advances in the luminescence spectroscopy in pharmaceutical analyses

    Get PDF
    This paper provides a review on the latest advances and applications of the luminescence spectroscopy for the development of pharmaceuticals analyses methods, basically based on the photo- and chemiluminescence. The different forms of the drugs determination on pharmaceuticals through the fluorescence and chemiluminescence are discussed. The analyses include the drugs native fluorescence (liquid and solid-phases); the fluorescence from the oxidizing or reducing forms of the drug; the fluorescence from the chemical derivatization and their photochemistry and hydrolysis reactions. The quenching of luminescence and chemiluminescence generation for the pharmaceutical quantification are also shown. Finally, the trends and future perspectives of the luminescence spectroscopy in the field of the pharmaceutical research are discussed.1755177

    Differentials in death count records by databases in Brazil in 2010

    Get PDF
    OBJECTIVE To compare the death counts from three sources of information on mortality available in Brazil in 2010, the Mortality Information System (SIM - Sistema de InformaçÔes sobre Mortalidade ), Civil Registration Statistic System (RC - Sistema de EstatĂ­sticas de Resgistro Civil ), and the 2010 Demographic Census at various geographical levels, and to confirm the association between municipal socioeconomic characteristics and the source which showed the highest death count. METHODS This is a descriptive and comparative study of raw data on deaths in the SIM, RC and 2010 Census databases, the latter held in Brazilian states and municipalities between August 2009 and July 2010. The percentage of municipalities was confirmed by the database showing the highest death count. The association between the source of the highest death count and socioeconomic indicators - the Índice de Privação Brasileiro (IBP – Brazilian Deprivation Index) and Índice de Desenvolvimento Humano Municipal (IHDM – Municipal Human Development Index) - was performed by bivariate choropleth and Moran Local Index of Spatial Association (LISA) cluster maps. RESULTS Confirmed that the SIM is the database with the highest number of deaths counted for all Brazilian macroregions, except the North, in which the highest coverage was from the 2010 Census. Based on the indicators proposed, in general, the Census showed a higher coverage of deaths than the SIM and the RC in the most deprived (highest IBP values) and less developed municipalities (lowest IDHM values) in the country. CONCLUSION The results highlight regional inequalities in how the databases chosen for this study cover death records, and the importance of maintaining the issue of mortality on the basic census questionnaire

    Stress analysis of a fixed implant-supported denture by the finite element method (FEM) when varying the number of teeth used as abutments

    Full text link
    OBJECTIVES: In some clinical situations, dentists come across partially edentulous patients, and it might be necessary to connect teeth to implants. The aim of this study was to evaluate a metal-ceramic fixed tooth/implant-supported denture with a straight segment, located in the posterior region of the maxilla, when varying the number of teeth used as abutments. MATERIALS AND METHODS: A three-element fixed denture composed of one tooth and one implant (Model 1), and a four-element fixed denture composed of two teeth and one implant (Model 2) were modeled. A 100 N load was applied, distributed uniformly on the entire set, simulating functional mastication, for further analysis of the SEQV (Von Mises) principal stresses, which were compared with the flow limit of the materials. RESULTS: In a quantitative analysis, it may be observed that in the denture with one tooth, the maximum SEQV stress was 47.84 MPa, whereas for the denture with two teeth the maximum SEQV stress was 35.82 MPa, both located in the region between the pontic and the tooth. CONCLUSION: Lower stresses were observed in the denture with an additional tooth. Based on the flow limit of the materials, porcelain showed values below the limit of functional mastication

    Differentials in death count records by databases in Brazil in 2010

    Get PDF
    Objective: To compare the death counts from three sources of information on mortality available in Brazil in 2010, the Mortality Information System (SIM – Sistema de InformaçÔes sobre Mortalidade ), Civil Registration Statistic System (RC – Sistema de EstatĂ­sticas de Resgistro Civil ), and the 2010 Demographic Census at various geographical levels, and to confirm the association between municipal socioeconomic characteristics and the source which showed the highest death count. Methods: This is a descriptive and comparative study of raw data on deaths in the SIM, RC and 2010 Census databases, the latter held in Brazilian states and municipalities between August 2009 and July 2010. The percentage of municipalities was confirmed by the database showing the highest death count. The association between the source of the highest death count and socioeconomic indicators – the Índice de Privação Brasileiro (IBP – Brazilian Deprivation Index) and Índice de Desenvolvimento Humano Municipal (IHDM – Municipal Human Development Index) – was performed by bivariate choropleth and Moran Local Index of Spatial Association (LISA) cluster maps. Results: Confirmed that the SIM is the database with the highest number of deaths counted for all Brazilian macroregions, except the North, in which the highest coverage was from the 2010 Census. Based on the indicators proposed, in general, the Census showed a higher coverage of deaths than the SIM and the RC in the most deprived (highest IBP values) and less developed municipalities (lowest IDHM values) in the country. Conclusion: The results highlight regional inequalities in how the databases chosen for this study cover death records, and the importance of maintaining the issue of mortality on the basic census questionnaire

    Mitochondrial physiology

    Get PDF
    As the knowledge base and importance of mitochondrial physiology to evolution, health and disease expands, the necessity for harmonizing the terminology concerning mitochondrial respiratory states and rates has become increasingly apparent. The chemiosmotic theory establishes the mechanism of energy transformation and coupling in oxidative phosphorylation. The unifying concept of the protonmotive force provides the framework for developing a consistent theoretical foundation of mitochondrial physiology and bioenergetics. We follow the latest SI guidelines and those of the International Union of Pure and Applied Chemistry (IUPAC) on terminology in physical chemistry, extended by considerations of open systems and thermodynamics of irreversible processes. The concept-driven constructive terminology incorporates the meaning of each quantity and aligns concepts and symbols with the nomenclature of classical bioenergetics. We endeavour to provide a balanced view of mitochondrial respiratory control and a critical discussion on reporting data of mitochondrial respiration in terms of metabolic flows and fluxes. Uniform standards for evaluation of respiratory states and rates will ultimately contribute to reproducibility between laboratories and thus support the development of data repositories of mitochondrial respiratory function in species, tissues, and cells. Clarity of concept and consistency of nomenclature facilitate effective transdisciplinary communication, education, and ultimately further discovery

    Mitochondrial physiology

    Get PDF
    As the knowledge base and importance of mitochondrial physiology to evolution, health and disease expands, the necessity for harmonizing the terminology concerning mitochondrial respiratory states and rates has become increasingly apparent. The chemiosmotic theory establishes the mechanism of energy transformation and coupling in oxidative phosphorylation. The unifying concept of the protonmotive force provides the framework for developing a consistent theoretical foundation of mitochondrial physiology and bioenergetics. We follow the latest SI guidelines and those of the International Union of Pure and Applied Chemistry (IUPAC) on terminology in physical chemistry, extended by considerations of open systems and thermodynamics of irreversible processes. The concept-driven constructive terminology incorporates the meaning of each quantity and aligns concepts and symbols with the nomenclature of classical bioenergetics. We endeavour to provide a balanced view of mitochondrial respiratory control and a critical discussion on reporting data of mitochondrial respiration in terms of metabolic flows and fluxes. Uniform standards for evaluation of respiratory states and rates will ultimately contribute to reproducibility between laboratories and thus support the development of data repositories of mitochondrial respiratory function in species, tissues, and cells. Clarity of concept and consistency of nomenclature facilitate effective transdisciplinary communication, education, and ultimately further discovery

    Stress analysis of a fixed implant-supported denture by the finite element method (FEM) when varying the number of teeth used as abutments

    No full text
    OBJECTIVES: In some clinical situations, dentists come across partially edentulous patients, and it might be necessary to connect teeth to implants. The aim of this study was to evaluate a metal-ceramic fixed tooth/implant-supported denture with a straight segment, located in the posterior region of the maxilla, when varying the number of teeth used as abutments. MATERIAL AND METHODS: A three-element fixed denture composed of one tooth and one implant (Model 1), and a four-element fixed denture composed of two teeth and one implant (Model 2) were modeled. A 100 N load was applied, distributed uniformly on the entire set, simulating functional mastication, for further analysis of the SEQV (Von Mises) principal stresses, which were compared with the flow limit of the materials. RESULTS: In a quantitative analysis, it may be observed that in the denture with one tooth, the maximum SEQV stress was 47.84 MPa, whereas for the denture with two teeth the maximum SEQV stress was 35.82 MPa, both located in the region between the pontic and the tooth. CONCLUSION: Lower stresses were observed in the denture with an additional tooth. Based on the flow limit of the materials, porcelain showed values below the limit of functional mastication

    Aplicação e avanços da espectroscopia de luminescĂȘncia em anĂĄlises farmacĂȘuticas

    No full text
    This paper provides a review on the latest advances and applications of the luminescence spectroscopy for the development of pharmaceuticals analyses methods, basically based on the photo- and chemiluminescence. The different forms of the drugs determination on pharmaceuticals through the fluorescence and chemiluminescence are discussed. The analyses include the drugs native fluorescence (liquid and solid-phases); the fluorescence from the oxidizing or reducing forms of the drug; the fluorescence from the chemical derivatization and their photochemistry and hydrolysis reactions. The quenching of luminescence and chemiluminescence generation for the pharmaceutical quantification are also shown. Finally, the trends and future perspectives of the luminescence spectroscopy in the field of the pharmaceutical research are discussed

    Carbamide Peroxide Determination in Tooth Whitening Using a Reagentless HRP-Biosensor

    No full text
    A rapid and effective method for carbamide peroxide (CP) quantification in pharmaceuticals is proposed. The reagentless biosensor was prepared by using lyophilized turnip extract as horseradish peroxidase (HRP) enzyme source. The biosensor presented the best performance. The measurements were carried out in 0.1mol L-1 Pipes buffer (pH 6.0). At-100mV vs. Ag|AgCl, a linear response range from 3.0 to 25.0mmol L-1 was obtained. The quantification and detection limits were 1.2 and 0.4mmol L-1, respectively, and the response time was 0.5s. The biosensor repeatability, storage, and lifetime were excellent, allowing a satisfactory CP quantification in real pharmaceutical samples, when compared with those obtained by the official method.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq
    corecore