35 research outputs found

    First Responder Safety in the Event of a Dirty Bomb Detonation in Urban Environment

    Get PDF
    The malevolent dispersion of radioactive material, with the aim of contaminating people and the environment, is considered a credible terroristic threat. This article analyzes a hypothetical Dirty Bomb detonation in an urban area, estimating the radiological consequences to the involved population and to first responders. The dispersion of radioactive material is simulated using the HOTSPOT code, considering the explosion of devices containing (alternatively) 60Co, 137Cs, 192Ir, 238Pu or 241Am sources, frequently used in medical or industrial settings. Each source is evaluated separately. The resulting ground deposition is used to calculate the effective dose received by first responders in two different scenarios. Based on the dispersed radionuclide, the influence of the use of personal protective respirators is analyzed. Confirming previous published results, this article illustrates that the radioactive material is diluted by the detonation, resulting in relatively low doses to the general public. However, the emergency workers’ stay time in the most contaminated area must be carefully planned, in order to limit the received dose. Due to the general fear of radiation, extensive psychological effects are expected in the public, irrespective of the evaluated radiation dose

    A novel software platform for volumetric assessment of ablation completeness

    Get PDF
    Purpose: To retrospectively evaluate the accuracy of a novel software platform for assessing completeness of percutaneous thermal ablations. Materials & methods: Ninety hepatocellular carcinomas (HCCs) in 50 patients receiving percutaneous ultrasound-guided microwave ablation (MWA) that resulted in apparent technical success at 24-h post-ablation computed tomography (CT) and with ≥1-year imaging follow-up were randomly selected from a 320 HCC ablation database (2010–2016). Using a novel volumetric registration software, pre-ablation CT volumes of the HCCs without and with the addition of a 5 mm safety margin, and corresponding post-ablation necrosis volumes were segmented, co-registered and overlapped. These were compared to visual side-by-side inspection of axial images. Results: At 1-year follow-up, CT showed absence of local tumor progression (LTP) in 69/90 (76.7%) cases and LTP in 21/90 (23.3%). For HCCs classified by the software as "incomplete tumor treatments", LTP developed in 13/17 (76.5%) and all 13 (100%) of these LTPs occurred exactly where residual non-ablated tumor was identified by retrospective software analysis. HCCs classified as "complete ablation with <100% 5 mm ablative margins" had LTP in 8/49 (16.3%), while none of 24 HCCs with "complete ablation including 100% 5 mm ablative margins" had LTP. Differences in LTP between both partially ablated HCCs vs completely ablated HCCs, and ablated HCCs with <100% vs with 100% 5 mm margins were statistically significant (p < .0001 and p = .036, respectively). Thus, 13/21 (61.9%) incomplete tumor treatments could have been detected immediately, were the software available at the time of ablation. Conclusions: A novel software platform for volumetric assessment of ablation completeness may increase the detection of incompletely ablated tumors, thereby holding the potential to avoid subsequent recurrences

    Microwave ablation of primary and secondary liver tumours: ex vivo, in vivo, and clinical characterisation.

    Get PDF
    The aim of this study was to compare the performance of a microwave ablation (MWA) apparatus in preclinical and clinical settings.The same commercial 2.45 GHz MWA apparatus was used throughout this study. In total 108 ablations at powers ranging from 20 to 130 W and lasting from 3 to 30 min were obtained on ex vivo bovine liver; 28 ablations at 60 W, 80 W and 100 W lasting 5 and 10 min were then obtained in an in vivo swine model. Finally, 32 hepatocellular carcinomas (HCCs) and 19 liver metastases in 46 patients were treated percutaneously by administering 60 W for either 5 or 10 min. The treatment outcome was characterised in terms of maximum longitudinal and transversal axis of the induced ablation zone.Ex vivo ablation volumes increased linearly with deposited energy (rFor the selected MW ablation device, ex vivo data on bovine liver was more predictive of the actual clinical performance on liver malignancies than an in vivo porcine model. Equivalent MW treatments yielded a significantly different response for HCC and metastases at higher deposited energy, suggesting that outcomes are not only device-specific but must also be characterised on a tissue-by-tissue basis

    Chronic Treatment with Ivabradine Does Not Affect Cardiovascular Autonomic Control in Rats

    Get PDF
    A low resting heart rate (HR) would be of great benefit in cardiovascular diseases. Ivabradine a novel selective inhibitor of hyperpolarization-activated cyclic nucleotide gated (HCN) channels- has emerged as a promising HR lowering drug. Its effects on the autonomic HR control are little known. This study assessed the effects of chronic treatment with ivabradine on the modulatory, reflex and tonic cardiovascular autonomic control and on the renal sympathetic nerve activity (RSNA). Male Wistar rats were divided in 2 groups, receiving intraperitoneal injections of vehicle (VEH) or ivabradine (IVA) during 7 or 8 consecutive days. Rats were submitted to vessels cannulation to perform arterial blood pressure (AP) and HR recordings in freely moving rats. Time series of resting pulse interval and systolic AP were used to measure cardiovascular variability parameters. We also assessed the baroreflex, chemoreflex and the Bezold-Jarish reflex sensitivities. To better evaluate the effects of ivabradine on the autonomic control of the heart, we performed sympathetic and vagal autonomic blockade. As expected, ivabradine treated rats showed a lower resting (VEH: 362 +/- 16 bpm vs. IVA: 260 +/- 14 bpm, p = 0.0005) and intrinsic HR (VEH: 369 +/- 9 bpm vs. IVA: 326 +/- 11 bpm, p = 0.0146). However, the chronic treatment with ivabradine did not change normalized HR spectral parameters LF (nu) (VEH: 24.2 +/- 4.6 vs. IVA: 29.8 +/- 6.4p > 0.05)HF (nu) (VEH: 75.1 +/- 3.7 vs. IVA: 69.2 +/- 5.8p > 0.05), any cardiovascular reflexes, neither the tonic autonomic control of the HR (tonic sympathovagal indexVEH: 0.91 +/- 0.02 vs. IVA: 0.88 +/- 0.03, p = 0.3494). We performed the AP, HR and RSNA recordings in urethane-anesthetized rats. The chronic treatment with ivabradine reduced the resting HR (VEH: 364 +/- 12 bpm vs. IVA: 207 +/- 11 bpm, p < 0.0001), without affecting RSNA (VEH: 117 +/- 16 vs. IVA: 120 +/- 9 spikes/s, p = 0.9100) and mean arterial pressure (VEH: 70 +/- 4 vs. IVA: 77 +/- 6 mmHg, p = 0.3293). Our results suggest that, in health rats, the long-term treatment with ivabradine directly reduces the HR without changing the RSNA modulation and the reflex and tonic autonomic control of the heart.Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)Fundacao de Amparo a Pesquisa de Minas Gerais (FAPEMIG)Universidade Federal de Ouro Preto (UFOP)Universidade Federal do Triangulo Mineiro (UFTM), BrazilUniv Fed Ouro Preto, Inst Exact & Biol Sci, Dept Biol Sci, Lab Cardiovasc Physiol, Ouro Preto, BrazilUniv Fed Ouro Preto, CBIOL NUPEB, Grad Program Biol Sci, Ouro Preto, BrazilUniv Fed Minas Gerais, Inst Biol Sci, Dept Physiol & Biophys, Lab Hypertens, Belo Horizonte, MG, BrazilUniv Fed Sao Paulo, Inst Sci & Technol, Biomed Engn Lab, Sao Jose Dos Campos, BrazilUniv Uberaba, Dept Physiol, Uberaba, BrazilUniv Milan, Osped Maggiore Policlin, IRCCS Ca Granda Fdn, Dept Clin Sci & Community Hlth, Milan, ItalyFed Univ Trianaulo Pvlineiro, Inst Biol & Nat Sci, Dept Physiol, Uberaba, BrazilUniv Fed Sao Paulo, Inst Sci & Technol, Biomed Engn Lab, Sao Jose Dos Campos, BrazilCNPq: 400851/2014-8Web of Scienc

    Chronic treatment with ivabradine does not affect cardiovascular autonomic control in rats.

    Get PDF
    A low resting heart rate (HR) would be of great benefit in cardiovascular diseases. Ivabradine-a novel selective inhibitor of hyperpolarization-activated cyclic nucleotide gated (HCN) channels- has emerged as a promising HR lowering drug. Its effects on the autonomic HR control are little known. This study assessed the effects of chronic treatment with ivabradine on the modulatory, reflex and tonic cardiovascular autonomic control and on the renal sympathetic nerve activity (RSNA). Male Wistar rats were divided in 2 groups, receiving intraperitoneal injections of vehicle (VEH) or ivabradine (IVA) during 7 or 8 consecutive days. Rats were submitted to vessels cannulation to perform arterial blood pressure (AP) and HR recordings in freely moving rats. Time series of resting pulse interval and systolic AP were used to measure cardiovascular variability parameters. We also assessed the baroreflex, chemoreflex and the Bezold-Jarish reflex sensitivities. To better evaluate the effects of ivabradine on the autonomic control of the heart, we performed sympathetic and vagal autonomic blockade. As expected, ivabradine-treated rats showed a lower resting (VEH: 362 ? 16 bpm vs. IVA: 260 ? 14 bpm, p = 0.0005) and intrinsic HR (VEH: 369 ? 9 bpm vs. IVA: 326 ? 11 bpm, p = 0.0146). However, the chronic treatment with ivabradine did not change normalized HR spectral parameters LF (nu) (VEH: 24.2 ? 4.6 vs. IVA: 29.8 ? 6.4; p > 0.05); HF (nu) (VEH: 75.1 ? 3.7 vs. IVA: 69.2 ? 5.8; p > 0.05), any cardiovascular reflexes, neither the tonic autonomic control of the HR (tonic sympathovagal index; VEH: 0.91? 0.02 vs. IVA: 0.88 ? 0.03, p = 0.3494). We performed the AP, HR and RSNA recordings in urethane-anesthetized rats. The chronic treatment with ivabradine reduced the resting HR (VEH: 364 ? 12 bpm vs. IVA: 207 ? 11 bpm, p < 0.0001), without affecting RSNA (VEH: 117 ? 16 vs. IVA: 120 ? 9 spikes/s, p = 0.9100) and mean arterial pressure (VEH: 70 ? 4 vs. IVA: 77 ? 6 mmHg, p = 0.3293). Our results suggest that, in health rats, the long-term treatment with ivabradine directly reduces the HR without changing the RSNA modulation and the reflex and tonic autonomic control of the heart

    The role of immune suppression in COVID-19 hospitalization: clinical and epidemiological trends over three years of SARS-CoV-2 epidemic

    Get PDF
    Specific immune suppression types have been associated with a greater risk of severe COVID-19 disease and death. We analyzed data from patients &gt;17 years that were hospitalized for COVID-19 at the “Fondazione IRCCS Ca′ Granda Ospedale Maggiore Policlinico” in Milan (Lombardy, Northern Italy). The study included 1727 SARS-CoV-2-positive patients (1,131 males, median age of 65 years) hospitalized between February 2020 and November 2022. Of these, 321 (18.6%, CI: 16.8–20.4%) had at least one condition defining immune suppression. Immune suppressed subjects were more likely to have other co-morbidities (80.4% vs. 69.8%, p &lt; 0.001) and be vaccinated (37% vs. 12.7%, p &lt; 0.001). We evaluated the contribution of immune suppression to hospitalization during the various stages of the epidemic and investigated whether immune suppression contributed to severe outcomes and death, also considering the vaccination status of the patients. The proportion of immune suppressed patients among all hospitalizations (initially stable at &lt;20%) started to increase around December 2021, and remained high (30–50%). This change coincided with an increase in the proportions of older patients and patients with co-morbidities and with a decrease in the proportion of patients with severe outcomes. Vaccinated patients showed a lower proportion of severe outcomes; among non-vaccinated patients, severe outcomes were more common in immune suppressed individuals. Immune suppression was a significant predictor of severe outcomes, after adjusting for age, sex, co-morbidities, period of hospitalization, and vaccination status (OR: 1.64; 95% CI: 1.23–2.19), while vaccination was a protective factor (OR: 0.31; 95% IC: 0.20–0.47). However, after November 2021, differences in disease outcomes between vaccinated and non-vaccinated groups (for both immune suppressed and immune competent subjects) disappeared. Since December 2021, the spread of the less virulent Omicron variant and an overall higher level of induced and/or natural immunity likely contributed to the observed shift in hospitalized patient characteristics. Nonetheless, vaccination against SARS-CoV-2, likely in combination with naturally acquired immunity, effectively reduced severe outcomes in both immune competent (73.9% vs. 48.2%, p &lt; 0.001) and immune suppressed (66.4% vs. 35.2%, p &lt; 0.001) patients, confirming previous observations about the value of the vaccine in preventing serious disease

    Thermal Ablation of Liver Tumors Guided by Augmented Reality: An Initial Clinical Experience

    No full text
    Background: Over the last two decades, augmented reality (AR) has been used as a visualization tool in many medical fields in order to increase precision, limit the radiation dose, and decrease the variability among operators. Here, we report the first in vivo study of a novel AR system for the guidance of percutaneous interventional oncology procedures. Methods: Eight patients with 15 liver tumors (0.7&ndash;3.0 cm, mean 1.56 + 0.55) underwent percutaneous thermal ablations using AR guidance (i.e., the Endosight system). Prior to the intervention, the patients were evaluated with US and CT. The targeted nodules were segmented and three-dimensionally (3D) reconstructed from CT images, and the probe trajectory to the target was defined. The procedures were guided solely by AR, with the position of the probe tip was subsequently confirmed by conventional imaging. The primary endpoints were the targeting accuracy, the system setup time, and targeting time (i.e., from the target visualization to the correct needle insertion). The technical success was also evaluated and validated by co-registration software. Upon completion, the operators were assessed for cybersickness or other symptoms related to the use of AR. Results: Rapid system setup and procedural targeting times were noted (mean 14.3 min; 12.0&ndash;17.2 min; 4.3 min, 3.2&ndash;5.7 min, mean, respectively). The high targeting accuracy (3.4 mm; 2.6&ndash;4.2 mm, mean) was accompanied by technical success in all 15 lesions (i.e., the complete ablation of the tumor and 13/15 lesions with a &gt;90% 5-mm periablational margin). No intra/periprocedural complications or operator cybersickness were observed. Conclusions: AR guidance is highly accurate, and allows for the confident performance of percutaneous thermal ablations

    Pre and Post Liver Lesion Thermal ablation FDG-PET: background driven GMM segmentation

    No full text
    Two novel and innovative segmentation algorithms are presented, for liver metastases and necrotic tissues in pre- and post-ablation, respectively. Both are based on Gaussian Mixture Model (GMM), adapted to include healthy liver knowledge and proximity information. Preliminary validation results on 20 patients and 42 lesions are discussed showing high accuracy versus manual segmentation gold standard outperforming simpler GMM and thresholding methods

    Apparent mass matrix of standing subjects exposed to multi-axial whole-body vibration

    No full text
    This paper describes the experimental characterisation of the apparent mass matrix of eight male subjects in standing position and the identification of nonlinearities under both mono-axial and dual-axis whole-body vibration. The nonlinear behaviour of the response was studied using the conditioned response techniques considering models of increasing complexity. Results showed that the cross-axis terms are comparable to the diagonal terms. The contribution of the nonlinear effects are minor and can be endorsed to the change of modal parameters during the tests. The nonlinearity generated by the vibration magnitude is more evident in the subject response, since magnitude-dependent effects in the population are overlaid by the scatter in the subjects’ biometric data. The biodynamic response is influenced by the addition of a secondary vibration axis and, in case of dual-axis vibrations, the overall magnitude has a marginal contribution. Practitioner Summary: We have measured both the diagonal and cross-axis elements of the apparent mass matrix. The effect of nonlinearities and the simultaneous presence of vibration along two axes are smaller than the inter-subject variability

    Spostamento, velocitĂ  e accelerazione di vibrazione. Valutazioni metrologiche e confronto fra segnali misurati e calcolati

    No full text
    È noto che fenomeni vibratori di una certa persistenza o entità possano causare danni sia di natura estetica sia strutturale a edifici e strutture, oltre che fastidio negli occupanti. Tali effetti sono solitamente valutati mediante misure delle grandezze cinematiche che descrivono la vibrazione, ossia spostamento, velocità e accelerazione. Nonostante sia teoricamente possibile misurare una qualsiasi di queste grandezze e ricavare le altre tramite integrazione o derivazione, la misura diretta risulta solitamente quella che garantisce un’incertezza di misura inferiore. In caso di indisponibilità di trasduttori specifici o di inadeguatezza delle loro caratteristiche metrologiche, la misura indiretta può essere l’unica strada possibile. Scopo del presente lavoro è l’analisi comparativa da un punto di vista metrologico di misure dirette e indirette di quantità cinematiche. L’articolo descrive i risultati di una campagna sperimentale effettuata su uno shaker elettrodinamico, che ha permesso di valutare l’incertezza di misura di misure dirette e indirette effettuate con trasduttori di spostamento, velocità e accelerazione di diverse tipologie. I risultati hanno evidenziato che le operazioni di derivazione e integrazione singola consentono di ottenere incertezze solitamente inferiori al 3%
    corecore