77 research outputs found
The strain distribution in the lumbar anterior longitudinal ligament is affected by the loading condition and bony features: An in vitro full-field analysis
The role of the ligaments is fundamental in determining the spine biomechanics in physiological and pathological conditions. The anterior longitudinal ligament (ALL) is fundamental in constraining motions especially in the sagittal plane. The ALL also confines the intervertebral discs, preventing herniation. The specific contribution of the ALL has indirectly been investigated in the past as a part of whole spine segments where the structural flexibility was measured. The mechanical properties of isolated ALL have been measured as well. The strain distribution in the ALL has never been measured under pseudo-physiological conditions, as part of multi-vertebra spine segments. This would help elucidate the biomechanical function of the ALL. The aim of this study was to investigate in depth the biomechanical function of the ALL in front of the lumbar vertebrae and of the intervertebral disc. Five lumbar cadaveric spine specimens were subjected to different loading scenarios (flexion-extension, lateral bending, axial torsion) using a state-of-the-art spine tester. The full-field strain distribution on the anterior surface was measured using digital image correlation (DIC) adapted and validated for application to spine segments. The measured strain maps were highly inhomogeneous: the ALL was generally more strained in front of the discs than in front of the vertebrae, with some locally higher strains both imputable to ligament fibers and related to local bony defects. The strain distributions were significantly different among the loading configurations, but also between opposite directions of loading (flexion vs. extension, right vs. left lateral bending, clockwise vs. counterclockwise torsion). This study allowed for the first time to assess the biomechanical behaviour of the anterior longitudinal ligament for the different loading of the spine. We were able to identify both the average trends, and the local effects related to osteophytes, a key feature indicative of spine degeneration
Planning the Surgical Correction of Spinal Deformities: Toward the Identification of the Biomechanical Principles by Means of Numerical Simulation
The set of surgical devices and techniques to perform spine deformity correction has widened dramatically. Nevertheless, the rate of complications due to mechanical failure remains rather high. Indeed, basic research about the principles of deformity correction and the optimal surgical strategies (i.e. the choice of the fusion length, the most appropriate instrumentation, the degree of tolerable correction) did not progress as much as the techniques. In this work, a software approach for the biomechanical simulation of the correction of patient-specific spinal deformities aimed to the identification of its biomechanical principles is presented. The method is based on three dimensional reconstructions of the spinal anatomy obtained from biplanar radiographic images. A user-friendly graphical interface allows for the planning of the deformity correction and to simulate the instrumentation. Robust meshing of the instrumented spine is provided by using consolidated computational geometry and meshing libraries. Based on finite element simulation, the program predicts the loads acting in the instrumentation as well as in the biological tissues. A simple test case (reduction of a low grade spondylolisthesis at L3-L4) was simulated as a proof-of-concept. Despite the limitations of this approach, the preliminary outcome is promising and encourages a wide effort towards its refinement
A comparative analysis of a disposable and a reusable pedicle screw instrument kit for lumbar arthrodesis: integrating HTA and MCDA
Objective: Lumbar arthrodesis is a common surgical technique that consists of the fixation of one or more motion segments with pedicle screws and rods. However, spinal surgery using these techniques is expensive and has a significant impact on the budgets of hospitals and Healthcare Systems. While reusable and disposable instruments for laparoscopic interventions have been studied in literature, no specific information exists regarding instrument kits for lumbar arthrodesis. The aim of the present study was to perform a complete health technology assessment comparing a disposable instrument kit for lumbar arthrodesis (innovative device) with the standard reusable instrument. Methods: A prospective and observational study was implemented, by means of investigation of administrative records of patients undergoing a lumbar arthrodesis surgical procedure. The evaluation was conducted in 2013, over a 12- month time horizon, considering all the procedures carried out using the two technologies. A complete health technology assessment and a multi-criteria decision analysis approach were implemented in order to compare the two alternative technologies. Economic impact (with the implementation of an activity based costing approach), social, ethical, organisational, and technology-related aspects were taken into account. Results: Although the cost analysis produced similar results in the comparison of the two technologies (total cost equal to € 4,279.1 and € 4,242.6 for reusable instrument kit and the disposable one respectively), a significant difference between the two instrument kits was noted, in particular concerning the organisational impact and the patient safety. Conclusions: The replacement of a reusable instrument kit for lumbar arthrodesis, with a disposable one, could improve the management of this kind of devices in hospital settings
Intervertebral disc and endplate cell characterisation highlights annulus fibrosus cells as the most promising for tissue-specific disc degeneration therapy
Degenerative processes of the intervertebral disc (IVD) and cartilaginous endplate lead to chronic spine pathologies. Several studies speculated on the intrinsic regenerative capacity of degenerated IVD related to the presence of local mesenchymal progenitors. However, a complete characterisation of the resident IVD cell populations, particularly that isolated from the endplate, is lacking. The purpose of the present study was to characterise the gene expression profiles of human nucleus pulposus (NPCs), annulus fibrosus (AFCs) and endplate (EPCs) cells, setting the basis for future studies aimed at identifying the most promising cells for regenerative purposes. Cells isolated from NP, AF and EP were analysed after in vitro expansion for their stemness ability, immunophenotype and gene profiles by large-scale microarray analysis. The three cell populations shared a similar clonogenic, adipogenic and osteogenic potential, as well as an immunophenotype with a pattern resembling that of mesenchymal stem cells. NPCs maintained the greatest chondrogenic potential and shared with EPCs the loss of proliferation capability during expansion. The largest number of selectively highly expressed stemness, chondrogenic/tissue-specific and surface genes was found in AFCs, thus representing the most promising source of tissue-specific expanded cells for the treatment of IVD degeneration
SPINE20 A global advocacy group promoting evidence-based spine care of value
PURPOSE: The Global Burden of Diseases (GBD) Studies have estimated that low back pain is one of the costliest ailments worldwide. Subsequent to GBD publications, leadership of the four largest global spine societies agreed to form SPINE20. This article introduces the concept of SPINE20, the recommendations, and the future of this global advocacy group linked to G20 annual summits. METHODS: The founders of SPINE20 advocacy group coordinated with G20 Saudi Arabia to conduct the SPINE20 summit in 2020. The summit was intended to promote evidence-based recommendations to use the most reliable information from high-level research. Eight areas of importance to mitigate spine disorders were identified through a voting process of the participating societies. Twelve recommendations were discussed and vetted. RESULTS: The areas of immediate concern were "Aging spine," "Future of spine care," "Spinal cord injuries," "Children and adolescent spine," "Spine-related disability," "Spine Educational Standards," "Patient safety," and "Burden on economy." Twelve recommendations were created and endorsed by 31/33 spine societies and 2 journals globally during a vetted process through the SPINE20.org website and during the virtual inaugural meeting November 10-11, 2020 held from the G20 platform. CONCLUSIONS: This is the first time that international spine societies have joined to support actions to mitigate the burden of spine disorders across the globe. SPINE20 seeks to change awareness and treatment of spine pain by supporting local projects that implement value-based practices with healthcare policies that are culturally sensitive based on scientific evidence
SPINE20 recommendations 2021: spine care for people's health and prosperity
PURPOSE: The focus of SPINE20 is to develop evidence-based policy recommendations for the G20 countries to work with governments to reduce the burden of spine disease, and disability. METHODS: On September 17-18, 2021, SPINE20 held its annual meeting in Rome, Italy. Prior to the meeting, the SPINE20 created six proposed recommendations. These recommendations were uploaded to the SPINE20 website 10Â days before the meeting and opened to the public for comments. The recommendations were discussed at the meeting allowing the participants to object and provide comments. RESULTS: In total, 27 societies endorsed the following recommendations. SPINE20 calls upon the G20 countries: (1) to expand telehealth for the access to spine care, especially in light of the current situation with COVID-19. (2) To adopt value-based interprofessional spine care as an approach to improve patient outcomes and reduce disability. (3) To facilitate access and invest in the development of a competent rehabilitation workforce to reduce the burden of disability related to spine disorders. (4) To adopt a strategy to promote daily physical activity and exercises among the elderly population to maintain an active and independent life with a healthy spine, particularly after COVID-19 pandemic. (5) To engage in capacity building with emerging countries and underserved communities for the benefit of spine patients. (6) To promote strategies to transfer evidence-based advances into patient benefit through effective implementation processes. CONCLUSIONS: SPINE20's initiatives will make governments and decision makers aware of efforts to reduce needless suffering from disabling spine pain through education that can be instituted across the globe
Results of the spine-to-rib-cage distraction in the treatment of early onset scoliosis
BACKGROUND: Growing rod systems have been used in the last 30 years for the treatment of early onset scoliosis (EOS) with variable success rates. We report the results of treatment of EOS with a newly developed hybrid rod distraction system applied to the rib cage and spine with a nonfusion technique in a prospective multicenter clinical trial. MATERIALS AND METHODS: A total of 22 patients affected by progressive EOS resistant to cast and/or brace treatment were enrolled from 2004 to 2005 after informed consent into a trial of surgical treatment with a single spine-to-rib growing rod instrumentation growing spine profiler (GSP). Curves >60° Cobb in the frontal plane or bending < 50% were addressed with staged anterior annulotomy and fusion and posterior implantation of a GSP rod. Less severe and rigid curves were treated with posterior implantation of GSP only. The elongation of GSP was planned according to spinal growth. Patients were kept in a brace between elongations. RESULTS: A total of 20 patients were available to follow-up with complete data. The mean follow up is 4.1 years. Mean age at time of initial surgery was 5 years (3–8). Nine patients had staged antero-posterior surgeries, 11 posterior only surgeries. Mean spinal growth was 1.9 cm (1.5–2.3) or 0.5 cm per year. Mean coronal Cobb's angle correction was from 56° to 45°. Major complications affected 40% of patients and included rod failure in 6/20 and crankshaft in 5/20 (all in the anteroposterior surgery group). CONCLUSION: Treatment of EOS with spine-to-rib growing rod in the present form provides similar correction and complication rates to those published in the series considering traditional single or dual growing rod systems. Based on this, the authors recommend revision of the GSP design and a new clinical trial to test safety and efficacy
Is the transport of a gadolinium-based contrast agent decreased in a degenerated or aged disc? A post contrast MRI study.
A post contrast magnetic resonance imaging study has been performed in a wide population of low back pain patients to investigate which radiological and phenotypic characteristics influence the penetration of the contrast agent in lumbar discs in vivo. 37 patients affected by different pathologies (disc herniation, spondylolisthesis, foraminal stenosis, central canal stenosis) were enrolled in the study. The selected population included 26 male and 11 female subjects, with a mean age of 42.4 ± 9.3 years (range 18-60). Magnetic resonance images of the lumbar spine were obtained with a 1.5 T scanner (Avanto, Siemens, Erlangen, Germany) with a phased-array back coil. A paramagnetic non-ionic contrast agent was injected with a dose of 0.4 ml/kg. T1-weighted magnetic resonance images were subsequently acquired at 5 time points, 5 and 10 minutes, 2, 4 and 6 hours after injection. Endplates presented clear enhancement already 5 minutes after injection, and showed an increase in the next 2 hours followed by a decrease. At 5 and 10 minutes, virtually no contrast medium was present inside the intervertebral disc; afterwards, enhancement significantly increased. Highly degenerated discs showed higher enhancement in comparison with low and medium degenerated discs. Discs classified as Pfirrmann 5 showed a statistically significant higher enhancement than Pfirrmann 1, 2 and 3 at all time points but the first one, possibly due to vascularization. Disc height collapse and Modic changes significantly increased enhancement. Presence of endplate defects did not show any significant influence on post contrast enhancement, but the lack of a clear classification of endplate defects as seen on magnetic resonance scans may be shadowing some effects. In conclusion, disc height, high level of degeneration and presence of Modic changes are factors which increase post contrast enhancement in the intervertebral disc. The effect of age could not be demonstrated
Vertebroplasty and kyphoplasty: complementary tecniques for the treatment of painful osteoporotic vertebral compression fractures
OBJECTIVE: in a prospective study, we aimed to evaluate the potential use of kyphoplasty (KP) and vertebroplasty (VP) as complementary techniques in the treatment of painful osteoporotic vertebral compression fractures (VCFs). METHODS: after one month of conservative treatment for VCFs, patients with intractable pain were offered treatment with KP or VP according to a treatment algorithm that considers time from fracture (Ă„t) and amount of Vertebral Body Collapse (VBC). Bone biopsy was obtained intraoperatively to exclude patients affected by malignancy or osteomalacia. RESULTS: hundred and sixty-four patients were included according to the above criteria. Mean age was 67.6 years. Mean followup was 33 months. Ten patients (6.1%) were lost to follow-up and 154 reached the minimum two years follow-up. 118 (69.5%) underwent VP and 36 (30.5%) underwent KP. Complications affected five patients treated with VP, whose one suffered a transient intercostal neuropathy and four a subsequent VCF (two at adjacent level). Results in terms of VAS and Oswestry scores were not different among treatment groups. CONCLUSION: in conclusion, at an average follow-up of almost 3 years from surgical treatment of osteoporotic VCFs, VP and KP show similar good clinical outcomes and appear to be complementary techniques with specific different indications
Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
Pedicle subtraction osteotomy (PSO) is an invasive surgical technique allowing the restoration of a well-balanced sagittal profile, however, the risks of pseudarthrosis and instrumentation breakage are still high. Literature studied primary stability and posterior instrumentation loads, neglecting the load shared by the anterior column, which is fundamental to promote fusion early after surgery. The study aimed at quantifying the load-sharing occurring after PSO procedure across the ventral spinal structures and the posterior instrumentation, as affected by simple bilateral fixation alone, with interbody cages adjacent to PSO level and supplementary accessory rods. Lumbar spine segments were loaded in vitro under flexion-extension, lateral bending, and torsion using an established spine tester. Digital image correlation (DIC) and strain-gauge (SG) analyses measured, respectively, the full-field strain distribution on the ventral surface of the spine and the local strain on posterior primary rods. Ventral strains considerably decreased following PSO and instrumentation, confirming the effectiveness of posterior load-sharing. Supplemental accessory rods considerably reduced the posterior rod strains only with interbody cages, but the ventral strains were unaffected: this indicates that the load transfer across the osteotomy could be promoted, thus explaining the higher fusion rate with decreased rod fracture risk reported in clinical literature
- …