237 research outputs found

    Nature Inspired Solutions for Polymers: Will Cutinase Enzymes Make Polyesters and Polyamides Greener?

    Get PDF
    5siThe polymer and plastic sectors are under the urge of mitigating their environmental impact. The need for novel and more benign catalysts for polyester synthesis or targeted functionalization led, in recent years, to an increasing interest towards cutinases due to their natural ability to hydrolyze ester bonds in cutin, a natural polymer. In this review, the most recent advances in the synthesis and hydrolysis of various classes of polyesters and polyamides are discussed with a critical focus on the actual perspectives of applying enzymatic technologies for practical industrial purposes. More specifically, cutinase enzymes are compared to lipases and, in particular, to lipase B from Candida antarctica, the biocatalyst most widely employed in polymer chemistry so far. Computational and bioinformatics studies suggest that the natural role of cutinases in attacking natural polymers confer some essential features for processing also synthetic polyesters and polyamides.openopenFerrario, Valerio; Pellis, Alessandro; Cespugli, Marco; Guebitz, Georg; Gardossi, LuciaFerrario, Valerio; Pellis, Alessandro; Cespugli, Marco; Guebitz, Georg; Gardossi, Luci

    Prolonged job strain reduces time-domain heart rate variability on both working and resting days among cardiovascular-susceptible nurses

    Get PDF
    Introduction Modifications of hearth rate variability (HRV) constitute a marker of the autonomic nervous system (ANS) deregulation, a promising pathway linking job strain (JS) and cardiovascular diseases (CVD). The study objective is to assess whether exposures to recent and prolonged JS reduce time-domain HRV parameters on working days (WD) among CVD-susceptible nurses and whether the association also persists on resting days (RD). Material and methods 313 healthy nurses were investigated twice with one year interval to assess JS based on the demand-control and the effort-reward models. 36, 9 and 16 CVD-susceptible nurses were classified as low JS in both surveys (stable low strain – SLS), recent high JS (high JS at the second screening only-RHS) and prolonged high JS (high strain in both surveys-PHS), respectively. In 9, 7 and 10 of them, free from comorbidities/treatments interfering with HRV, two 24-h ECG recordings were performed on WD and RD. Differences in the time domain HRV metrics among JS categories were assessed using ANCOVA, adjusted for age and smoking. Results In the entire sample (mean age: 39 years, 83% females) the prevalence of high job strain was 38.7% in the second survey. SDNN (standard deviation of all normal RR intervals) on WD significantly declined among JS categories (p = 0.02), with geometric mean values of 169.1, 145.3 and 128.9 ms in SLS, RHS, PHS, respectively. In the PHS group, SDNN remained lower on RD as compared to the low strain subjects (142.4 vs. 171.1 ms, p = 0.02). Similar findings were found for the SDNN_Index, while SDANN (standard deviation of average RR intervals in all 5 min segments of registration) mean values reduced in the PHS group during WD only. Conclusions Our findings suggest that persistent JS lowers HRV time-domain parameters, supporting the hypothesis that the ANS disorders may play an intermediate role in the relationship between work stress and CVD

    Measurement of power spectral density of broad-spectrum visible light with heterodyne near field scattering and its scalability to betatron radiation.

    Get PDF
    We exploit the speckle field generated by scattering from a colloidal suspension to access both spatial and temporal coherence properties of broadband radiation. By applying the Wiener-Khinchine theorem to the retrieved temporal coherence function, information about the emission spectrum of the source is obtained in good agreement with the results of a grating spectrometer. Experiments have been performed with visible light. We prove more generally that our approach can be considered as a tool for modeling a variety of cases. Here we discuss how to apply such diagnostics to broad-spectrum betatron radiation produced in the laser-driven wakefield accelerator under development at SPARC LAB facility in Frascati

    Intense terahertz pulses from SPARC-LAB coherent radiation source

    Get PDF
    The linac-based Terahertz source at the SPARC_LAB test facility is able to gene rate highly intense Terahertz broadband pulses via coherent transition radiation (CTR) from high brightness electron beams. The THz pulse duration is typically down to 100 fs RMS and can be tuned through the electron bunch duration and shaping. The measured stored energy in a single THz pulse has reached 40 μ J, which corresponds to a peak electric field of 1.6 MV/cm at the THz focus. Here we present the main features, in particular spatial and sp ectral distributions and energy characterizations of the SPARC_LAB THz source, which is very competitive for investigations in Condensed Matter, as well as a valid tool for electron beam longitudinal diagnostics

    Fully renewable polyesters via polycondensation catalyzed by Thermobifida cellulosilytica cutinase 1: an integrated approach

    Get PDF
    The present study addresses comprehensively the problem of producing polyesters through sustainable processes while using fully renewable raw materials and biocatalysts. Polycondensation of bio-based dimethyl adipate with different diols was catalyzed by cutinase 1 from Thermobifida cellulosilytica (Thc_cut1) under solvent free and thin-film conditions. The biocatalyst was immobilized efficiently on a fully renewable cheap carrier based on milled rice husk. A multivariate factorial design demonstrated that Thc_cut1 is less sensitive to the presence of water in the system and it works efficiently under milder conditions (50 \ub0C; 535 mbar) when compared to lipase B from Candida antarctica (CaLB), thus enabling energy savings. Experimental and computational investigations of cutinase 1 from Thermobifida cellulosilytica (Thc_cut1) disclosed structural and functional features that make this serine-hydrolase efficient in polycondensation reactions. Bioinformatic analysis performed with the BioGPS tool pointed out functional similarities with CaLB and provided guidelines for future engineering studies aiming, for instance, at introducing different promiscuous activities in the Thc_cut1 scaffold. The results set robust premises for a full exploitation of enzymes in environmentally and economically sustainable enzymatic polycondensation reactions

    Drug eluting stents are superior to bare metal stents to reduce clinical outcome and stent-related complications in CKD patients, a systematic review, meta-analysis and network meta-analysis.

    Get PDF
    AimsTo compare clinical outcome in Chronic kidney disease (CKD) patients receiving coronary stents according to stent type BMS versus DES and 1st generation versus 2nd generation DES.Methods and ResultsPubMed, Cinhal, Cochrane, Embase, and Web of Science were searched for studies including CKD patients. CKD was defined as eGFR < 60 mL/min. We selected n = 35 articles leading to 376 169 patients, of which 76 557 CKD patients receiving BMS n = 35,807, 1st generation DES n = 37,650, or 2nd generation DES n = 3100. Patient receiving DES, compared to BMS, had a 18% lower all‐cause mortality (RR 0.82, 95%CI 0.71‐0.94). The composite of death or myocardial infarction (MI) was lower in DES patients (RR 0.78, 95%CI 0.67‐0.91), as was stent thrombosis (ST) (RR 0.57, 95%CI 0.34‐0.95), target vessel/lesion revascularization (TVR/TLR) (RR 0.69, 95%CI 0.57‐0.84) and death for cardiovascular cause (RR 0.43, 95%CI 0.25‐0.74). We also found a gradient between 1st and 2nd generation DES, through BMS. Second, compared to 1st generation DES, were associated with further relative risk (RR) reduction of −18% in of all‐cause death, and lower incidence of stent‐related clinical events: −39% RR of ST risk; −27 RR of TVR/TLR risk.ConclusionsDES in CKD patients undergoing PCI were superior to BMS in reducing major adverse clinical events. This was possibly explained, by a lower risk of stent‐related events as ST and TVR or TLR. Second, compared to 1st generation DES may furtherly reduce clinical events
    corecore